1. Introduction
The HW632 XH-M603 Charging Control Module is an intelligent device designed to automatically manage the charging process of 12V to 24V lithium batteries. It features a digital LED display for real-time voltage monitoring and user-configurable start and stop charging voltage thresholds. This module ensures optimal battery life by preventing overcharging and undercharging, acting as a protective switch for your battery system.
2. Safety Information
- Always disconnect power before making any connections to prevent electric shock or damage to the module and battery.
- Ensure correct polarity when connecting the charger input and battery. Incorrect wiring can cause irreversible damage.
- Do not exceed the specified input voltage range (10-30VDC).
- Keep the module away from water, moisture, and extreme temperatures.
- Handle with care to avoid static discharge, which can damage electronic components.
- This module is a control device; ensure your charger is appropriate for your battery type and capacity.
3. Product Overview
The HW632 XH-M603 module integrates a digital LED display, two control buttons, input/output terminals, and a relay for switching the charging current. Its compact design makes it suitable for various battery management applications.

Figure 1: Top view of the HW632 XH-M603 module, highlighting the LED display, control buttons, and connection terminals.

Figure 2: Module dimensions: approximately 8.2cm (3.22 inches) in length and 5.8cm (2.28 inches) in width.
4. Setup
4.1 Wiring Diagram
Follow the diagram below carefully to connect the charging input and the battery to the module. Ensure all connections are secure and observe correct polarity.

Figure 3: Wiring diagram. Connect your charger to the 'Charger input' terminals and your 12-24V battery to the 'Detection side' terminals. Note the positive (+) and negative (-) markings.
- Charger Input: Connect your DC power supply/charger (10-30VDC) to the input terminals labeled 'Charger input' or '+IN' and '-IN'.
- Battery Connection: Connect the battery (12-24V) to the terminals labeled 'Detection side' or '+BAT' and '-BAT'. These terminals are used for both voltage detection and charging current output.
4.2 Initial Power-up
Once wired correctly, apply power to the charger input. The digital LED display on the module should light up, showing the current battery voltage. If the display does not light up, check your power supply and wiring connections.
5. Operating Instructions
The module features two buttons, typically labeled '启动' (Start) and '停止' (Stop), used to set the charging thresholds.

Figure 4: Control buttons for setting voltage thresholds.
5.1 Setting Voltage Thresholds
- Set Start Charging Voltage (Lower Limit):
- Press and hold the '启动' (Start) button for approximately 3 seconds. The LED display will start flashing, indicating it's in setting mode for the start voltage.
- Use the '启动' (Start) button to increase the voltage value and the '停止' (Stop) button to decrease it.
- Once the desired start voltage is set, wait for the display to stop flashing (about 3 seconds) to automatically save the setting.
- Set Stop Charging Voltage (Upper Limit):
- Press and hold the '停止' (Stop) button for approximately 3 seconds. The LED display will start flashing, indicating it's in setting mode for the stop voltage.
- Use the '启动' (Start) button to increase the voltage value and the '停止' (Stop) button to decrease it.
- Once the desired stop voltage is set, wait for the display to stop flashing (about 3 seconds) to automatically save the setting.
5.2 Displaying Set Voltages
- View Start Voltage: Short press the '启动' (Start) button once. The display will momentarily show the set start charging voltage.
- View Stop Voltage: Short press the '停止' (Stop) button once. The display will momentarily show the set stop charging voltage.
5.3 Reset to Factory Defaults
To reset all settings to their factory default values, press and hold both the '启动' (Start) and '停止' (Stop) buttons simultaneously for approximately 5 seconds. The display will show '888' or similar to confirm the reset.
5.4 Charging Process Operation
Once the start and stop voltages are set:
- When the battery voltage drops below the set Start Charging Voltage, the module's relay will close, allowing current from the charger to flow to the battery, initiating the charging process.
- When the battery voltage reaches the set Stop Charging Voltage, the module's relay will open, disconnecting the charger from the battery and stopping the charging process.
- The module will continuously monitor the battery voltage and automatically manage the charging cycle.
6. Maintenance
- Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Periodically check all wiring connections to ensure they are secure and free from corrosion.
- Avoid exposing the module to direct sunlight for prolonged periods or environments with high humidity.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Module display is off / Device silent | No power to input; Incorrect polarity; Faulty module. | Check charger input voltage (10-30VDC); Verify wiring polarity; Ensure connections are secure. |
| Battery not charging | Start voltage set too low; Stop voltage set too high; Charger not working; Battery faulty. | Adjust start voltage to be higher than current battery voltage; Check charger output; Test battery. |
| Battery overcharging | Stop voltage set too high; Module malfunction. | Lower the stop voltage threshold; If problem persists, module may be faulty. |
| Battery undercharging | Stop voltage set too low. | Increase the stop voltage threshold. |
8. Specifications
| Feature | Specification |
|---|---|
| Model | HW632 XH-M603 |
| Input Voltage (Charger) | DC 10 - 30V |
| Battery Voltage Range | DC 12 - 24V (Universal) |
| Control Precision | 0.1V |
| Display Type | Digital LED |
| Output Type | Direct Output (Relay Control) |
| Max Relay Current | 20A |
| Operating Temperature | -10 to 70 Celsius |
| Dimensions (L x W) | 8.2cm x 5.8cm (approx. 3.22in x 2.28in) |
| Application | 12-24V Lithium Battery Charging Control, General Battery Protection |
9. User Tips
- For High Current Applications: If your charging current exceeds the module's internal relay rating (20A), it is recommended to use this module to control an external, higher-rated relay or contactor. This will protect the module from damage.
- Solar Panel Compatibility: This module can be used with solar charging systems. The settings are non-volatile, meaning they will not be lost if power to the module is interrupted (e.g., during nighttime). Ensure your solar charge controller provides a stable DC output within the module's input voltage range.
- Automotive Battery Charging: The module is suitable for controlling the charging of automotive batteries (12V or 24V). The actual charging current and speed will depend on the charger you connect to the module.
- Voltage Display: The module primarily displays voltage. It does not directly control or display charging current (amperes).
10. Warranty and Support
For any issues, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.