1. Product Overview
The ATORCH HD10 is a versatile DC Current Meter designed to measure and display various electrical parameters including voltage, current, power, energy, capacity, temperature, and timing. It features a clear LCD monitor and is suitable for a wide range of electrical applications.
Key Features:
- Multi-functional display: Voltage, Current, Power, Energy, Capacity, Temperature, Timing.
- Wide measurement range: 0.00V~150V, 0.00A~20.0A, 0~3000W.
- High accuracy for precise measurements.
- Compact design for easy integration.
- Includes a waterproof temperature probe.
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure all connections are secure and correctly polarized before applying power.
- Do not exceed the maximum specified voltage (150V) or current (20A).
- Avoid contact with live circuits.
- Do not operate the device in wet or damp conditions.
- This device is intended for DC circuits only. Do not connect to AC power.
- No user-serviceable parts inside. Do not attempt to disassemble or repair.
3. Installation and Wiring
The ATORCH HD10 DC Current Meter is designed for inline measurement. Follow the diagrams carefully for correct installation.
3.1 Physical Dimensions
The compact size of the meter allows for easy integration into various setups.

Dimensions: 47 * 28 * 21mm / 1.85 * 1.1 * 0.83in (L * W * H)
3.2 Wiring Diagram
Connect the meter in series with the load. The input terminals connect to the power source (e.g., battery), and the output terminals connect to the load. Ensure correct polarity (IN+ to positive, IN- to negative, OUT+ to positive load, OUT- to negative load).


Connection Steps:
- Identify the IN+ and IN- terminals for the power input.
- Identify the OUT+ and OUT- terminals for the load output.
- Connect the positive terminal of your DC power source (5V-150V) to the IN+ terminal of the meter.
- Connect the negative terminal of your DC power source to the IN- terminal of the meter.
- Connect the positive terminal of your load (0-3000W) to the OUT+ terminal of the meter.
- Connect the negative terminal of your load to the OUT- terminal of the meter.
- Ensure all connections are tight and secure to prevent loose contacts and inaccurate readings.
- The meter includes an internal shunt for current measurement up to 20A, so an external shunt is not required.
The meter can be powered by the measured voltage itself (self-powered) if the voltage is within the supply voltage range of 4-30V (via 2.54pin) or 0.00V-150V (main input). For lower voltages, an external power supply might be needed for the meter's operation, though the main input range is 0.00V-150V.
4. Operation
Once correctly wired and powered, the ATORCH HD10 will display real-time electrical parameters on its LCD screen.
4.1 Display Modes
The meter cycles through various measurement displays, showing voltage, current, power, energy, capacity, temperature, and timing. The main display shows voltage and current prominently.
4.2 Key Functions
The "Key" button on the front panel is used for specific functions, primarily for resetting accumulated data.
- Short Press: Cycles through display modes or changes specific settings (refer to detailed instructions for advanced settings).
- Long Press: Resets accumulated capacity (Ah) and energy (Wh) data. This is useful for measuring the capacity of a battery or the energy consumed by a load over a specific period.
4.3 Temperature Measurement
The included 1-meter waterproof temperature probe can be connected to the meter to display ambient or component temperature. Ensure the probe is placed in the area you wish to monitor.
4.4 Measuring Battery Capacity (Ah)
To measure the capacity of a battery (e.g., 750Ah automotive battery), connect the battery as the power source and a suitable load through the meter. Long press the "Key" button to reset the capacity (Ah) and energy (Wh) readings to zero. Allow the battery to discharge through the load until it reaches its desired discharge voltage. The accumulated Ah reading will indicate the discharged capacity.
5. Maintenance
To ensure the longevity and accurate performance of your ATORCH HD10 DC Current Meter, follow these simple maintenance guidelines:
- Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Connections: Periodically check all wiring connections to ensure they remain tight and free from corrosion.
- Environmental Conditions: Avoid exposing the meter to excessive dust, moisture, or corrosive environments. The operating temperature range is -10°C to +60°C.
6. Troubleshooting
If you encounter issues with your ATORCH HD10, refer to the following troubleshooting tips:
- No Display/Meter Not Turning On:
- Check power connections to IN+ and IN-. Ensure the supply voltage is within the specified range (0.00V~150V for main input, or 4~30V for 2.54pin auxiliary power).
- Verify that the power source is active.
- Inaccurate Current Readings (Fluctuations or High/Low):
- Ensure all wiring connections are secure and there are no loose contacts.
- Verify that the load is within the 0-20A measurement range.
- Calibration: If the current reading is consistently off, calibration may be required. To calibrate, you will need a stable 60V source and a 10A load. Connect the 60V source to the input while holding down the "Key" button. After calibration, the voltage can be reduced, and the load applied.
- Voltage Fluctuations (0.7-0.8V):
- Check the stability of your power source.
- Ensure connections are robust and free from interference.
- Display Too Small/Hard to Read:
- This is a characteristic of the compact design. Ensure adequate lighting and viewing angle.
7. Specifications
| Parameter | Value |
|---|---|
| Brand Name | ATORCH |
| Model Number | HD10 |
| Display Type | Digital Only |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE |
| Dimensions (L*W*H) | 47 * 28 * 21mm / 1.85 * 1.1 * 0.83in |
| Operating Temperature | -10~+60°C |
| Supply Voltage | 0.00V~150V & 4~30V (2.54pin) |
| Accuracy Class | 1.0 |
| Measuring Range | 0.00V~150V / 0.00A~20.0A / 0 ~ 3000W |
| Measurement Time | >0.5W |
| Battery Included | No |
| High-concerned chemical | None |
8. User Tips
- Compact Display: Due to its small size, the display can be dense with information. Ensure good lighting and a direct viewing angle for optimal readability.
- Response Time: The meter reacts with a slight delay to changes in current and voltage, but this delay is generally less than standard meters.
- Wide Voltage Compatibility: The meter can handle a broad range of DC voltages up to 150V, making it suitable for various battery types, including 12V systems and higher voltage setups.
- Internal Shunt: This model features an internal shunt, eliminating the need for a separate external shunt for measurements within its specified current range (up to 20A).
- Capacity Measurement: To accurately measure battery capacity (Ah), ensure the meter's accumulated data is reset before starting the discharge cycle.
9. Warranty and Support
ATORCH products are manufactured to high-quality standards. For any issues or technical support, please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.
This product is certified with CE, indicating compliance with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA).