1. Introduction

This manual provides detailed instructions for the ATORCH A-35WFZW+DCJ 35W Constant Current Load Tester. This device is designed for aging and discharge testing of 3.7V 18650 batteries and other DC power sources. It features a constant current load, dual adjustable knobs for precise current control, and a digital display for real-time monitoring of various electrical parameters.

2. Safety Information

  • Always ensure correct polarity when connecting batteries or power sources. Incorrect connections can damage the device or the power source.
  • Do not exceed the maximum voltage and current ratings specified in the specifications.
  • The device can generate heat during operation, especially at higher power levels. Ensure adequate ventilation and do not block the cooling fan.
  • Keep the device away from moisture and extreme temperatures.
  • Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
  • Use appropriate safety precautions when handling batteries, such as wearing eye protection.

3. Product Overview

The ATORCH A-35WFZW+DCJ features a compact design with multiple input interfaces and a clear digital display. Key components and interfaces are:

Diagram of ATORCH Load Tester interfaces and components

Figure 3.1: Device Interfaces and Components

  • USB Input: Standard USB-A male connector for connecting to USB power sources (1-25V, 0.1-4.5A).
  • Other USB Inputs: Mini USB, Type-C USB, Micro USB, iPhone USB ports for various input sources.
  • Independent Power Supply Micro USB Interface: For powering the device's internal system separately.
  • Reserved DIY Terminal Voltage Input: Screw terminals (V+, V-) for connecting external power sources or battery holders.
  • Double Adjustable Design (Current Adjusting Knobs): Two rotary knobs for precise current control.
  • Current Fine Adjustment Knob: Adjusts current in smaller increments (+/-0.2A).
  • Current Coarse Adjustment Knob: Adjusts current in larger increments (0.1-4.5A).
  • High Power Copper Roller Fan: For active cooling during discharge.
  • Real-time Monitor (Tester): 0.96" 128x64 LCD display for showing measurement data.
  • Multifunction Button: Used for data reset and switching display interfaces.
  • LED Light: Indicator light.
  • System Prompts Warning Horn: Audible alerts.

4. Setup

Before operation, ensure the device is placed on a stable, well-ventilated surface.

4.1. Connecting a Battery for Test

To test a 3.7V 18650 battery using a battery holder (not included):

  1. Connect the positive (V+) and negative (V-) terminals of the battery holder to the corresponding screw terminals on the load tester. Ensure correct polarity.
  2. Insert the 18650 battery into the holder.
Connection diagram for 18650 battery holder

Figure 4.1: Connecting an 18650 Battery Holder

4.2. Connecting a USB Power Source

To test a USB power source:

  1. Plug the USB-A male connector of the load tester directly into the USB output port of the power source (e.g., power bank, charger).
  2. Alternatively, use the Mini USB, Type-C USB, Micro USB, or iPhone USB input ports with appropriate cables.

4.3. Powering the Device

The device can be powered in two ways:

  • Independent Power Supply: Connect a 4-25V DC power source to the independent power supply Micro USB interface. This is recommended when testing low voltage inputs or when the input being tested might not provide stable power to the tester itself.
  • Test Input Power Supply: If the system power supply switch is directed to the load inside, the device can draw power directly from the test input (4-25V range). This mode is suitable for testing power sources within this voltage range.

5. Operating Instructions

Once the device is connected and powered, the LCD display will show real-time measurement data.

Close-up of the display showing voltage, current, capacity, energy, temperature, and time

Figure 5.1: Example Display Screen 1

Close-up of the display showing detailed voltage, current, resistance, D+/D- voltages, temperature, and time

Figure 5.2: Example Display Screen 2

5.1. Adjusting the Load Current

Use the two adjustable knobs to set the desired discharge current:

  • Rotate the Coarse Adjustment Knob to set the main current value (0.1-4.5A).
  • Rotate the Fine Adjustment Knob for precise adjustments in smaller increments (+/-0.2A).

The display will show the real-time current draw.

5.2. Display Information

The 0.96" 128x64 LCD display shows various parameters:

  • Vol: Voltage (V)
  • Cur: Current (A)
  • Cap: Cumulative Capacity (mAh)
  • Ene: Cumulative Energy (Wh)
  • Time: Elapsed time (HH:MM:SS)
  • Temp: Operating Temperature (°C)
  • Ω: Resistance (Ohms)
  • D+/D-: Data line voltages (for USB testing)

5.3. Multifunction Button Operations

The multifunction button controls data reset and interface switching:

  • Long Press (Main Interface): Resets and clears cumulative capacity (mAh), energy (Wh), and time (00:00:00) to zero.
  • Double Click: Resets and clears cumulative capacity (mAh) to zero.
  • Triple Click: Resets and clears cumulative energy (Wh) to zero.
  • Quadruple Click: Resets and clears elapsed time (00:00:00) to zero.
  • Five Clicks: Sets up automatic standby mode and current long standby mode.
  • Six Clicks: Switches the display interface language between Chinese and English.

5.4. Setting Cut-off Voltage (for Li-Ion Batteries)

The device supports setting a cut-off voltage for battery discharge tests. For Li-Ion batteries, you can set a limit (e.g., 2.7V). When the battery voltage drops to this set value, the device will beep and automatically stop the discharge, preventing over-discharge.

5.5. Temperature Control Fan

The integrated fan automatically activates to cool the device when the internal temperature rises, ensuring stable operation and preventing overheating.

6. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Do not use abrasive cleaners or solvents.
  • Ensure the cooling fan is not obstructed by dust or debris.
  • Store the device in a cool, dry place when not in use.

7. Troubleshooting

7.1. Common Issues and Solutions

Problem Possible Cause Solution
Device does not power on / Display is blank. No power input or incorrect connection. Ensure a power source is connected correctly to either the USB input or the independent Micro USB port. Check cable connections.
High temperature / Fan constantly running or device feels hot. Operating at high power, insufficient ventilation. Ensure the fan is not obstructed. Reduce the load current if possible. Operate in a well-ventilated area.
Current meter jumps around / Unstable readings. Poor connection, unstable power source, or internal interference. Check all connections for tightness. Ensure the power source is stable. Try using the independent power supply for the tester.
Device makes whistling/hissing noises. Normal operation noise from components under load, or fan noise. Some noise is normal for electronic loads. If excessive, ensure the fan is clean and not obstructed.

7.2. Calibration Note

Please note that the device's calibration is primarily based on voltage. Current calibration may not be as precise. For applications requiring extremely high current accuracy, external calibration or verification with a high-precision ammeter is recommended.

8. Specifications

Parameter Value
Model Number A-35WFZW+DCJ
Brand Name ATORCH
DIY Supplies Electrical
Power Supply DC
Display Type Digital Only (0.96" 128x64 LCD)
Load Capacity 35W Constant Current
Voltage Measuring Range USB Input: 1V~25V; Independent/Test Input: 4V~25V
Current Measuring Range 0.1A~4.50A
Accuracy Class 1.0
Cumulative Capacity Range 0~99999mAh
Power Cumulative Range 0~999999 MWH
Power Metering Range 0~299.999 W (Measurement only, not load capacity)
Timing Maximum Time 999 H 59 M 59 S
Maximum Over Temperature Range 0~80 °C
Operating Temperature -10 degrees to +60 degrees
Working Humidity 10 ~ 80%
Pressure of Work 80 ~ 106 KPa
Measurement Rate 0.5 times/s
Battery Included No
Certification CE, RoHS
Origin Mainland China

9. User Tips

  • Setting Discharge Limits: Utilize the cut-off voltage feature for Li-Ion batteries to prevent over-discharge and prolong battery life. A common safe lower limit for Li-Ion is 2.7V.
  • Stable Readings: If you experience fluctuating current readings, double-check all connections and ensure your power source is stable. Using the independent Micro USB power input for the tester itself can sometimes help stabilize readings.
  • Cooling: The device can get warm during high-power discharge. Always ensure the fan is unobstructed and the device is in a well-ventilated area to maintain optimal performance and longevity.
  • Versatile Use: This tester is not just for 18650 batteries; its multiple input options (USB-A, Micro USB, Type-C, iPhone, screw terminals) make it suitable for testing various DC power sources and USB chargers.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.