LILYTECH ZL-7816A

Contents

ZL-7816A Temperature and Humidity Controller

Brand: LILYTECH | Model: ZL-7816A

1. Introduction

The LILYTECH ZL-7816A is a microcomputer-controlled temperature and humidity controller designed for precise environmental management. It features easy operation with slight key presses and a clear digital display for both temperature and humidity. This device is capable of controlling temperature and humidity independently and includes an auto-restart function, retaining all settings after a power cycle. The sensor can be extended up to 50 meters for stable and reliable data collection, making it suitable for various applications such as incubators, greenhouses, and industrial settings.

ZL-7816A controller with sensor, showing temperature and humidity display
Figure 1: ZL-7816A Temperature and Humidity Controller with its sensor.

2. Specifications

Feature Specification
Power Supply 12Vac or 12Vdc
Sensor Input One humidity and temperature sensor (1.5m wire, stable up to 50m)
Sensor Precision (25°C) Humidity ±3% RH; Temperature ±1%
Setting Range (Humidity) 0.0 ~ 99.9% RH
Setting Range (Temperature) 0.0 ~ 80.0°C
Output Load ≤ 7A (250Vac pure resistance) per output
Working Environment -10 ~ 45°C; ≤ 90% RH (without dew)
Power Consumption < 2W
Compatible Sensors ZL-SHR04 or ZL-SHR05
Dimensions 118 x 75 x 32 mm

3. Safety Warnings

Failure to follow these warnings may result in damage to the device, property, or personal injury.

  1. Do not connect wiring when power is supplied to the device.
  2. Electrical wiring must be performed by a certified electrician.
  3. Read this manual carefully and connect according to the electrical wiring diagram. Incorrect connections will damage the device.
  4. Do not route the sensor cable bundle together with power supply cables to avoid interference.
  5. Avoid operating the device in erosive, wet, or strong electrical-magnetic field environments, as these conditions can affect its correct functioning.
  6. This device is checked before shipment. The warranty is one year; however, damage due to wrong usage, such as incorrect wiring, is not covered.

4. Installation

The ZL-7816A controller is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Refer to the diagram below for precise installation dimensions.

Installation dimensions diagram for the ZL-7816A controller
Figure 2: Installation dimensions (in mm) for panel mounting.

5. Wiring Diagram

Always ensure power is disconnected before performing any wiring.

The ZL-7816A requires a 12V AC/DC power supply. It provides separate outputs for temperature and humidity loads. Connect the sensor to the designated T/H Sensor terminals. The load outputs (TempLoad and HumiLoad) are relay contacts that can switch AC220V for your heating/cooling and humidifying/dehumidifying devices.

Wiring diagram for ZL-7816A, showing connections for power, sensor, humidity load, and temperature load
Figure 3: Electrical wiring diagram for ZL-7816A. Connect 12V AC/DC to power, sensor to T/H Sensor, and loads to HumiLoad/TempLoad.

For detailed sensor information, refer to the ZL-SHR04J sensor diagram:

ZL-SHR04J sensor with pinout diagram
Figure 4: ZL-SHR04J Sensor with VCC, GND, and SDA connections.

6. Operating Instructions

6.1 Display Indicators

  • If the sensor is not connected correctly or fails, the display will show "---".
  • When the temperature output is energized, the upper LED labeled "OUT" illuminates.
  • When the humidity output is energized, the lower LED labeled "OUT" illuminates.

6.2 Setting Operation

  1. To enter the setting status, press and hold the S button for 2 seconds.
  2. The upper display window will show the parameter code, and the lower window will show its current value.
  3. Press the S button to cycle through the parameter codes.
  4. Use the ▲ or ▼ buttons to adjust the value of the selected parameter. Hold the button for faster adjustment.
  5. To exit the setting status and save all changes, press and hold the S button for 2 seconds.
  6. Note: The device will automatically exit the setting status and save changes if no key is operated for 30 seconds.

6.3 Parameter Settings

Code Function Set Range Remark Factory Set
TCTemperature control modeCO/HECO: Cool, HE: HeatHE
TSPTemperature Setting0.0 ~ 99.9°C37.5
TdTemperature hysteresis0.0 ~ 30.0°C0.1
TCATemperature calibration-5.0 ~ 5.0°C0.0
THAHigh temperature alarm hysteresis0.0 ~ 30.0°C0: Disable0.5
TLALow temperature alarm hysteresis0.0 ~ 30.0°C0: Disable1.5
HCHumidity control modeH/PH: Humidify P: DehumidifyH
HSPHumidity Setting0.0 ~ 99.9% RH52.0
HdHumidity hysteresis0.0 ~ 30.0% RH0.2
HCAHumidity calibration-5.0 ~ 5.0% RH0.0
HHAHigh humidity alarm hysteresis0.0 ~ 30.0% RH0: Disable10.0
HLALow humidity alarm hysteresis0.0 ~ 30.0% RH0: Disable5.0
SHrSelect Sensor4~54:ZL-SHR04 5:ZL-SHR055
BABuzzer alarm0~10: Disable 1: Enable1

6.4 Control Function Logic

Temperature Control

  • Cool Mode (TC = CO):
    • When room temperature ≥ TSP + Td, the temperature load turns ON.
    • When room temperature ≤ TSP, the temperature load turns OFF.
  • Heat Mode (TC = HE):
    • When room temperature ≤ TSP - Td, the temperature load turns ON.
    • When room temperature ≥ TSP, the temperature load turns OFF.

Humidity Control

  • Humidify Mode (HC = H):
    • When room humidity < HSP - Hd, the humidity load turns ON.
    • When room humidity ≥ HSP, the humidity load turns OFF.
  • Dehumidify Mode (HC = P):
    • When room humidity ≥ HSP + Hd, the humidity load turns ON.
    • When room humidity ≤ HSP, the humidity load turns OFF.

Over Temperature/Humidity Warning

  • Over Temperature Warning:
    • When room temperature ≥ TSP + THA, a high temperature warning occurs (LED display THi).
    • When room temperature ≤ TSP - TLA, a low temperature warning occurs (LED display TLo).
  • Over Humidity Warning:
    • When room humidity ≥ HSP + HHA, a high humidity warning occurs (LED display HHi).
    • When room humidity ≤ HSP - HLA, a low humidity warning occurs (LED display HLo).

7. Calibration

The measured room temperature can be calibrated using the TCA parameter.

The measured room humidity can be calibrated using the HCA parameter.

8. Restore to Factory Default Settings

To restore all parameters to factory default settings:

  1. Press and hold the ▲ and ▼ buttons simultaneously for 2 seconds.
  2. The device will display "UnL" + "0".
  3. Press the ▼ button three times. The controller will reset all parameters.

9. Troubleshooting

  • Display shows "---": The temperature and humidity sensor is either not connected properly or is faulty. Check the sensor connection and its condition.
  • Incorrect Temperature/Humidity Readings: Check the calibration parameters (TCA for temperature, HCA for humidity) and adjust if necessary. Ensure the sensor is in a representative location.
  • Device Not Powering On: Verify that the 12V AC/DC power supply is correctly connected and providing the specified voltage.
  • Load Not Activating: Check the wiring of the load (heater, cooler, humidifier, dehumidifier) to the controller's output terminals. Ensure the load's power consumption does not exceed the 7A output capacity. Verify that the control mode (TC, HC) and set points (TSP, HSP) are configured correctly.
  • Sensor Contacts Oxidized: If the sensor has been exposed to high humidity or water, its contacts may oxidize, leading to inaccurate readings or failure. Inspect the sensor and replace if necessary.

10. User Tips

  • Sensor Cable Extension: The sensor cable can be reliably extended up to 50 meters if needed for your application.
  • Incubator Use: This controller is highly effective for managing temperature and humidity in egg incubators, allowing for stable conditions without constant manual adjustment.
  • Sauna Applications: The ZL-7816A can be used for temperature and humidity control in saunas, provided the main controller unit is installed outside the hot, humid environment, and only the sensor is exposed to the sauna conditions.
  • Controlling Humidifiers/Dehumidifiers: The device can effectively control ultrasonic mist generators or other humidifiers/dehumidifiers by connecting them to the output relays and setting the appropriate humidity control mode.
  • Power Supply: The controller operates on 12V AC or DC. Ensure you have a compatible 12V power adapter.
  • Video Guides: For visual setup and operation instructions, searching for 'ZL-7816A setup' on video platforms like YouTube may provide helpful tutorials.

11. Warranty and Support

The LILYTECH ZL-7816A controller comes with a one-year warranty from the date of purchase. Please note that this warranty does not cover damage resulting from improper usage, incorrect wiring, or exposure to unsuitable environmental conditions as outlined in the safety warnings.

For further detailed instructions, technical support, or warranty claims, please refer to the official user manual PDF available at: ZL-7816A User Manual (PDF).

12. Frequently Asked Questions (FAQ)

Q: Can the device be connected to both AC and DC 12V? Is polarity important?
A: Yes, it can be connected to both AC and DC 12V. Polarity is not important for the power input terminals.
Q: Can this be used for an egg incubator?
A: Yes, it is suitable for controlling temperature and humidity in egg incubators.
Q: Can the sensor wire be extended?
A: Yes, the sensor wire can be extended up to 50 meters for stable operation.
Q: What is the maximum load current?
A: The output load current is ≤ 7A (250Vac pure resistance) per output.
Q: Can it control a humidifier or dehumidifier?
A: Yes, it can be configured to control both humidifiers (humidify mode) and dehumidifiers (dehumidify mode) based on set humidity levels.
Q: Does it show negative temperatures?
A: The temperature setting range is 0.0°C to 80.0°C. It does not show negative temperatures.
Q: What type of power supply is needed?
A: A 12V AC/DC power supply is required.
Q: Does it have an auto-restart function after power loss?
A: Yes, it has an auto-restart function and retains settings after power is restored.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.