1. Introduction

Thank you for choosing the ZHURUI PR10 Power Recorder. This device is designed to accurately measure and record the power consumption of various electrical appliances. To ensure optimal performance and durability, please read this manual carefully and keep it for future reference.

Product Overview

The PR10 Power Recorder features a 2.4-inch TFT color LCD screen, which can measure and display real-time parameters such as power, power factor, voltage, current, and frequency. It also records total power consumption, total power consumption time, electricity cost, single power consumption, single power consumption time, and electricity cost for various electrical appliances. Daily power consumption and electricity cost are recorded in real-time, and historical data can be viewed in charts or lists. The device is suitable for detecting and recording the operation and power consumption of electrical equipment in households, factories, offices, and other places. It can also turn electrical equipment on and off at scheduled times.

Main Features

  • Fully digital operation and control.
  • 2.4-inch TFT color LCD display.
  • 0.5-class measurement accuracy.
  • User interface in 9 languages (Chinese, English, Spanish, German, French, Italian, Russian, Japanese, Korean).
  • 23 types of currency units available for free setting.
  • Four operation buttons for easy navigation.
  • Date display and time can be set, supporting 5 date formats.
  • Adjustable power-on state: automatic power-on, no power-on, or maintain last state.
  • Power consumption statistics: total and current power consumption. Current power consumption can be cleared for specific measurements.
  • Three main display pages: overview, current power consumption, and real-time electrical parameters.
  • Automatic historical power consumption data recording for up to 30 years, viewable in lists or charts.
  • Electricity rate supports up to 4 decimal places, adjustable, and 8-time-period stepped pricing for peak-valley occasions.
  • 9 groups of timers (2 advanced, 7 general) for scheduled power on/off.
  • Alarm function for voltage, current, power, or temperature exceeding set values.
  • Output protection function with automatic power cut-off for over-limit conditions, including start-up overload mode and automatic recovery.
  • Energy-saving screen settings: auto-off after 1, 5, or 10 minutes of inactivity, or always on.
  • Functions for clearing total power consumption, historical records, and restoring factory settings.
  • Automatic power measurement resolution switching (0.01W for <100W, 0.1W for >=100W, 1W for >=1000W).
  • Over-range prompt.
  • Multiple plug types available: New National Standard 10A five-hole, National Standard 16A three-hole, European Standard 16A, French Standard 16A, American Standard 15A, and British Standard 13A.
  • Compact size, exquisite appearance, easy to carry.

2. Packing List

The product package includes the following items:

  • PR10 Power Recorder: 1 piece
  • User Manual: 1 copy
  • Warranty Card: 1 copy
  • Product Certificate: 1 piece

3. Safety Information

⚠ DANGER

Do not open the device or replace parts by yourself if a malfunction occurs, to avoid electric shock. There are no replaceable parts inside the device. In case of malfunction, please contact the manufacturer or authorized distributor.

Precautions:

  • The recorder cannot work in high-temperature and high-humidity environments. Please use it within the normal temperature and humidity range.
  • The working voltage range of the recorder should be kept between AC 85V and AC 265V.
  • The working current cannot exceed the maximum working current.
  • Do not expose the recorder to environments with excessive dust, corrosive gases, and other harmful substances during storage and use.
  • Do not touch the conductor parts of the socket plug of the instrument during the use of the recorder to avoid electric shock.

4. Product Models

The ZHURUI PR10 Power Recorder is available in several models to accommodate different plug types:

PR10 Power Recorder with various plug types: AU, EU, FR, US, UK
PR10 Power Recorder with different plug types
PR10-A AU Plug model
PR10-A AU Plug
PR10-C German Plug model
PR10-C German Plug
PR10-E US Plug model
PR10-E US Plug
PR10-F UK Plug model
PR10-F UK Plug

Please choose the appropriate model according to the plug type used in your country.

5. Setup

The PR10 Power Recorder features four operation buttons: "Set/Confirm" (≡/←), "Up/Switch" (▲/▲), "Down/Switch" (▼/▼), and "Return/Clear" (⤾/O).

Initial Setup and Navigation

  1. Entering the Setting Page:
    • Press the "Set/Confirm" (≡/←) button in the working state to pop up the system menu.
    • Use the "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) buttons to select the desired menu item. The selected item will be displayed with a blue background and white text.
    • If the selected item has a sub-menu, press the "Set/Confirm" (≡/←) button to enter the sub-menu. Otherwise, pressing "Set/Confirm" (≡/←) will enter the setting page directly.
    • Press the "Return/Clear" (⤾/O) button to exit the system menu.
  2. Button Functions in Setting Page:
    • Set/Confirm (≡/←): Confirms a number, checks/unchecks a box, selects a radio button, or confirms a setting.
    • Up/Switch (▲/▲): Decreases a number value, or jumps to the previous setting item.
    • Down/Switch (▼/▼): Increases a number value, or jumps to the next setting item.
    • Return/Clear (⤾/O): Exits the setting page without saving changes.
  3. Language Setting:
    • Navigate to the Language setting page.
    • Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to move the cursor to your desired language (e.g., English).
    • Press "Set/Confirm" (≡/←) to set the selected language.
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  4. Currency Setting:
    • Navigate to the Currency Unit setting page.
    • Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to select the desired currency unit.
    • Press "Set/Confirm" (≡/←) to set the selected currency unit.
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  5. Date Format Setting:
    • Navigate to the Date Format setting page.
    • Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to select the desired date format.
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  6. Time Setting:
    • Navigate to the Time Setting page.
    • Press "Set/Confirm" (≡/←) to start setting the time. The tens digit of the year will be highlighted.
    • Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to adjust the value, then "Set/Confirm" (≡/←) to move to the next digit.
    • Repeat until all digits are set.
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  7. Electricity Cost Setting (Charge Rate):
    • Navigate to the "General Settings" sub-menu and then to the Electricity Cost setting page.
    • To enable time-of-use pricing (stepped pricing), check the "Enable segment charge" box using "Set/Confirm" (≡/←). Otherwise, leave it unchecked for a single rate.
    • Adjust the number of decimal places for the electricity cost using "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼).
    • If time-of-use pricing is enabled, you will set up to 8 time periods with their respective charge rates. Use "Up/Switch" (▲/▲) and "Down/Switch" (▼/▼) to adjust the time segments and charge rates, and "Set/Confirm" (≡/←) to confirm.
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  8. Outlet Setting:
    • Navigate to the "Outlet Setting" page.
    • Select the desired outlet state after power on: "On" (always on), "Off" (always off), or "Same as last time" (retains the state before power-off).
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.
  9. Screen Setting:
    • Navigate to the "Screen Setting" page.
    • Select the desired screen turn-off time: "Turn off screen after 1 minute", "Turn off screen after 5 minutes", "Turn off screen after 10 minutes", or "Screen never turn off".
    • Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.

6. Operating Instructions

Main Display Pages

In working mode, the PR10 Power Recorder displays three main pages:

  1. Main Page 1 (Overview): Shows Voltage, Current, Power, Power Factor, Total kWh, OneShot kWh, and their respective costs.
  2. Main Page 2 (Current Power Consumption): Similar to Main Page 1, focusing on current consumption.
  3. Main Page 3 (Real-Time Parameter): Displays Power, Voltage, Current, Power Factor, and Frequency.

The overview page is displayed by default. Users can press the "Down/Switch" (▼/▼) button to switch between different main display pages.

PR10 Power Recorder showing Main Page 1, Main Page 2, and Main Page 3 displays
Main Display Pages (Page 1, Page 2, Page 3)

Status Bar Icons

  • Alarm Icon: Flashes when an alarm event occurs.
  • Timer Icon: Displayed when the timer is turned on.
  • Output Off Icon: Displayed when the socket output is off.
  • Output On Icon: Displayed when the socket output is on.
  • Main Page 1 Icon: Displayed when in Main Page 1.
  • Main Page 2 Icon: Displayed when in Main Page 2.
  • Main Page 3 Icon: Displayed when in Main Page 3.

Viewing Historical Records

  1. Press the "Set/Confirm" (≡/←) button in the working state to open the system menu.
  2. Use the "Down/Switch" (▼/▼) button to select the "Historical Records" menu item.
  3. Press the "Set/Confirm" (≡/←) button to open the historical records sub-menu.
  4. Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to select "Monthly Chart", "Monthly List", "Annual Chart", or "Annual List".
  5. Press "Set/Confirm" (≡/←) again to enter the historical record viewing page.
Historical Records - Monthly Chart and List
Example of Monthly Chart and List

Timer Settings

The PR10 has 9 sets of timers. Timers 1 and 2 are advanced timers, while Timers 3-9 are general timers.

Advanced Timers (Timer 1, Timer 2)

These timers allow you to set specific dates and times for power on/off actions, with options for "No Repeat", "Every Day", "Working Days", or "Weekends".

  1. Navigate to the "Timer Setting" page and select "Timer 1" or "Timer 2".
  2. Press "Set/Confirm" (≡/←) to start setting. The "Enable" checkbox will be highlighted.
  3. Select whether to enable the timer.
  4. Set the timer start date and time using "Up/Switch" (▲/▲), "Down/Switch" (▼/▼), and "Set/Confirm" (≡/←).
  5. Select the time option: "No Repeat", "Every Day", "Working Days", or "Weekends".
  6. Select the switch action: "Turn on Power" or "Turn off Power".
  7. Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.

General Timers (Timer 3-9)

These timers allow you to set specific times for power on/off actions, with an option to repeat daily.

  1. Navigate to the "Timer Setting" page and select a timer from "Timer 3" to "Timer 9".
  2. Press "Set/Confirm" (≡/←) to start setting. The "Enable" checkbox will be highlighted.
  3. Select whether to enable the timer.
  4. Set the timer start time using "Up/Switch" (▲/▲), "Down/Switch" (▼/▼), and "Set/Confirm" (≡/←).
  5. Check the "Repeat Every Day" box if you want the timer to execute daily. If unchecked, the timer will only execute once.
  6. Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.

Alarm Settings

The PR10 Power Recorder can be configured to trigger an alarm when certain parameters exceed predefined limits.

  1. Navigate to the "Alarm Setting" page.
  2. Press "Set/Confirm" (≡/←) to start setting the alarm function. The voltage alarm setting will be highlighted.
  3. Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to adjust the alarm voltage value, and "Set/Confirm" (≡/←) to move to the enable checkbox.
  4. Check or uncheck the "Enabled" box for the voltage alarm.
  5. Repeat steps 3 and 4 for Current, Power, and Temperature alarm settings.
  6. Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.

Output Protection Settings

This function automatically cuts off power when voltage, current, power, or temperature exceeds set values, ensuring safe operation.

  1. Set the output protection parameters for voltage, current, power, and temperature, similar to alarm settings.
  2. Launch Overload: Check this box if the measured equipment's start-up current might exceed the set output protection current (e.g., motors). This allows a 15-second grace period during start-up where current/voltage limits are not strictly enforced. This only takes effect if the load current exceeds 2A.
  3. Auto Recovery: Check this box to enable automatic power recovery. If the device cuts off power due to protection, it will automatically turn power back on after one minute if the parameters are within safe limits. If limits are exceeded again, it will cut off power again.
  4. Move the cursor to "OK" and press "Set/Confirm" (≡/←) to save and exit, or "Return/Clear" (⤾/O) to exit without saving.

7. Maintenance

System Settings (Clear Data, Factory Reset)

The PR10 Power Recorder allows you to clear recorded data and restore factory settings.

  1. Navigate to the "System Setting" page from the main menu.
  2. You will see options for "Clear total Energy", "Clear History", and "Factory Reset".
  3. Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to select the desired option.
  4. Press "Set/Confirm" (≡/←) to confirm the operation. A confirmation dialog will appear.
  5. Use "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) to select "OK" to proceed, or "Return/Clear" (⤾/O) to cancel.
  6. Caution: "Factory Reset" will clear all power consumption record data. Use this function with caution.

8. Troubleshooting

Problem PhenomenonSolution
After power-on, the device is not powered on, and the icon is displayed in the lower right corner of the screen.Long-press the "Up/Switch" (▲/▲) button for three seconds to turn on the power, or enter the "Outlet Setting" page, set the switch state to "Power on", and the recorder will automatically turn on the power to supply power to the device when it is powered on next time.
During the working process, the device power is cut off, the icon is displayed, or the icon flashes.The recorder has entered the output protection state. Check whether the voltage, current, power, and temperature exceed the set output protection values. If necessary, change the corresponding output protection setting values, cancel the corresponding output protection settings, or check the "Allow Start-up Overload" check box.
During the working process, the recorder beeps, and the icon in the lower right corner of the screen flashes.The recorder has entered the alarm state. Check whether the voltage, current, power, and temperature exceed the set alarm values. If necessary, you can change the corresponding alarm setting values or cancel the corresponding alarm settings.
The time and total power consumption are not saved after power-off.The built-in button battery is dead and needs to be replaced. The model of the button battery is: CR2032.

*During the setting process, long-pressing the "Up/Switch" (▲/▲) or "Down/Switch" (▼/▼) buttons can realize quick adjustment.

9. Specifications

Electrical Measurement Specifications

ParameterMeasurement RangeResolutionMeasurement Accuracy
VoltageAC85~265V0.1V±(0.5%FS+0.1V)
PR10-A (New National Standard 10A)
    Power0.1~2500W0.01W±(0.5%FS+0.01W)
    Current0.005~10A0.001A±(0.5%FS+0.001A)
PR10-B (National Standard 16A)
    Power0.1~4000W0.01W±(0.5%FS+0.01W)
    Current0.005~16A0.001A±(0.5%FS+0.001A)
PR10-C (European Standard 16A)
    Power0.1~4000W0.01W±(0.5%FS+0.01W)
    Current0.005~16A0.001A±(0.5%FS+0.001A)
PR10-D (French Standard 16A)
    Power0.1~4000W0.01W±(0.5%FS+0.01W)
    Current0.005~16A0.001A±(0.5%FS+0.001A)
PR10-E (American Standard 15A)
    Power0.1~3750W0.01W±(0.5%FS+0.01W)
    Current0.005~15A0.001A±(0.5%FS+0.001A)
PR10-F (British Standard 13A)
    Power0.1~3250W0.01W±(0.5%FS+0.01W)
    Current0.005~13A0.001A±(0.5%FS+0.001A)
Power factor0~1.0000.001±(0.5%FS+0.001)
Frequency45~65Hz0.1Hz±(0.5%FS+0.1Hz)
Electricity Cost0~9999990.01±(0.5%FS+0.01)
Power Consumption0~999999kWh0.00001kWh±(0.5%FS+0.00001kWh)

Notes on Electrical Measurement:

  • The measured values of voltage and current are true RMS values.
  • The measured power value is active power.
  • Power resolution: When power is less than 100W, resolution is 0.01W; when power is 100W or more, resolution is 0.1W; when power is 1000W or more, resolution is 1W.
  • Electricity cost resolution: When cost is less than 10000, resolution is 0.01; when cost is 10000 or more, resolution is 0.1; when cost is 100000 or more, resolution is 1.
  • Power consumption resolution is adjusted according to the measurement result, up to 0.00001 kWh.

Timing Specifications

  • Timing Range: 999 Days 23 Hours 59 Minutes
  • Timing Resolution: 1 Minute

Supported Currency Units

The device supports 23 currency units, including:

Currency NameCurrency Symbol
RMB (Simple)元
RMB (Tradition)圆
USD$
EUR€
GBP£
JPY¥
Roubleруб
RupeeRs.
Won원
Lire₤
Thai Baht฿
Peso₱
IDRRp
RMRM
RandR
Common Currency(various symbols)

Other Specifications

  • Operating Voltage: AC85~265V
  • Operating Frequency: 45~65Hz
  • Operating Temperature: 0~40°C
  • Humidity: ≤90%RH
  • Overall Dimensions (PR10-A, PR10-B, PR10-E, PR10-F): 125mm × 79mm × 38.5mm (height excluding plug)
  • Overall Dimensions (PR10-C, PR10-D): 125mm × 79mm × 56.5mm (height excluding plug)
  • Weight (PR10-A, PR10-B, PR10-E, PR10-F): 180g
  • Weight (PR10-C, PR10-D): 205g

10. User Tips

  • The internal battery is primarily for saving settings and data, not for powering the display when unplugged.
  • The device supports multi-tariff zones (e.g., day/night rates) with up to 4 configurable tariff zones.
  • All measurements are stored internally. Data cannot be directly extracted to a PC.
  • The device supports 9 languages, including English, Spanish, German, French, Italian, Russian, Japanese, Korean, and Chinese.
  • The screen has an auto-off feature after a set period of inactivity (1, 5, or 10 minutes) to save power, or it can be set to remain always on.
  • The device measures active power and displays the power factor (PF).
  • The device has a timer function that allows scheduling power on/off.
  • The device operates on both 127V and 220V within its AC85-265V range.
  • The device supports 50Hz and 60Hz frequencies.
  • To reset "OneShot" data, long-press the "Return/Clear" (⤾/O) button for more than 3 seconds.

11. Warranty and Support

Copyright © 2016 Shenzhen Zhurui Technology Co., Ltd. All rights reserved.

Without the written permission of Shenzhen Zhurui Technology Co., Ltd., no unit or individual shall arbitrarily extract or copy part or all of this manual, and shall not disseminate it in any form. The products described in this manual may contain hardware and software with copyrights owned by Shenzhen Zhurui Technology Co., Ltd. and its possible licensors. Unless otherwise permitted in writing by the relevant right holders, no one may copy, distribute, lease, transfer the aforementioned hardware and software in any form or commit other infringing acts.

Within the scope permitted by relevant laws, Shenzhen Zhurui Technology Co., Ltd. may modify the content of this manual under any circumstances.

For More Information

A PDF version of the user manual is available for download from the manufacturer's website.

12. Video Demonstration

This video demonstrates the PR10 Power Recorder's 2.4-inch color screen, its ability to measure power, power factor, voltage, current, and frequency, and its functions for recording total electricity consumption, time, and electricity bills for up to 30 years. It also shows the daily electricity consumption, time, and real-time electricity bill, along with its 0.5% measurement accuracy, 9-language user interface, 23 currency units, 5 date/time formats, alarm function, 9 timer sets, and various plug models (US, British, German, French, Australian).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.