1. General Introduction
This manual applies to FUZRR FR15B+ and FR17B+ True RMS digital multimeters. Both models are high-precision, safe, and portable handheld measuring instruments, widely used in electrical engineering maintenance, household circuit detection, electronic repair, industrial equipment inspection, and photovoltaic engineering testing.
The two meters adopt the same body size and safety protection design, with complete full-range overload protection, NCV non-contact voltage detection, data hold, and auto power-off functions. The core difference lies in counting resolution, measurement range, and functional configuration to meet different user needs of professional precision measurement and basic daily detection.
2. Product Overview & Key Features
2.1 Common Features
- True RMS Measurement: Accurately measure non-linear AC waveforms of inverters, motors, and variable-frequency equipment, avoiding data deviation of ordinary average-value multimeters.
- NCV Non-contact Voltage Detection: Safe induction of live wires, zero-fire line distinction, no need to contact the measured circuit to prevent electric shock risks.
- Full Safety Protection: CAT III 1000V / CAT IV 600V safety rating, anti-mis-insertion jack design, built-in fuse overload protection, anti-drop, and anti-skid body.
- Practical Intelligent Functions: Data hold, maximum value lock, backlight display, low battery reminder, auto power-off, buzzer prompt for on-off test.
- Durable Structure: IP54 dustproof and splash-proof grade, wearable body, suitable for complex indoor and outdoor working environments.
2.2 Model Differentiation
The FUZRR FR15B+ and FR17B+ models share many features but differ in specific capabilities:
- FUZRR FR15B+: Features 6000 counts high-definition display, higher measurement accuracy, supports conductivity measurement and VFD voltage detection, with a wider measurement range. Suitable for professional electronic maintenance and precision electrical detection.
- FUZRR FR17B+: Features 4000 counts display, stable basic measurement performance, and is cost-effective. Tailored for household detection, building wiring, and daily basic electrical maintenance.
3. Product Specifications
3.1 Physical Parameters (Both Models Consistent)
- Dimension: 183 mm × 91 mm × 45 mm
- Net Weight: FR15B+ ≈ 430g (with 2×AA batteries); FR17B+ ≈ 425g (with 2×AA batteries)
- Test Lead Length: 950mm
- Probe Length: 82mm
- Power Supply: 2×1.5V AA batteries
- Display: LCD backlight screen, Digital Display
- Operating Temperature: 0 - 50 ℃
- Safety Standard: CAT III 1000V, CAT IV 600V
- Protection Grade: IP54
3.2 Electrical Performance Parameters
| Function / Model | FR15B+ Specification | FR17B+ Specification | Accuracy |
|---|---|---|---|
| Display Counts | 6000 Counts | 4000 Counts | - |
| DC mV | 60.00mV / 600.0mV | 60.00mV / 600.0mV | ±(0.5%+3) |
| DC V | 6V / 60V / 600V / 1000V | 6V / 60V / 600V / 1500V | ±(0.5%+3) |
| AC mV | 60.00mV / 600.0mV | 60.00mV / 600.0mV | ±(0.8%+5) |
| ACV / Bandwidth (Hz) | 6V / 60V / 600V / 1000V / 1KHz | 6V / 60V / 600V / 1000V / 1KHz | ±(0.8%+5) |
| VFD (AC Voltage) Variable Frequency | 100 ~ 600V / 400Hz | 100 ~ 600V / 400Hz | - |
| Duty% | 10% ~ 90% | 10% ~ 90% | ±(2%+5) |
| DC Current (A) | 6mA / 60mA / 600mA / 6.000A / 10A | 6mA / 60mA / 600mA / 6.000A / 10A | ±(0.8%+5) / ±(1.5%+3) |
| AC / DC 600A (Current Clamp) | 0.1A ~ 600.0A (Input 1A = 1mV) | 0.1A ~ 600.0A (Input 1A = 1mV) | ±(3%+5) |
| Frequency (Hz) | 10Hz ~ 20MHz | 10Hz ~ 20MHz | ±(0.5%+5) |
| Resistance (Ω) | 600Ω / 6KΩ / 60KΩ / 600KΩ / 6MΩ / 60MΩ | 600Ω / 6KΩ / 60KΩ / 600KΩ / 6MΩ / 60MΩ | ±(0.8%+5) / ±(2.5%+5) |
| Capacitance (F) | 60nF ~ 600nF ~ 600uF / 60000uF | 60nF ~ 600nF ~ 600uF / 60000uF | ±(4%+5) / ±(8%+5) |
| Temperature (°C) | - | (-50°C ~ 1000°C) | ±(1.5%+4) |
| Temperature (°F) | - | (-58°F ~ 1832°F) | ±(2%+4) |
| VFD Voltage Detection | Support | Not support | - |
| True RMS | Auto | Auto | - |
| Continuity / Diode | ● | ● | - |
| Power | AA1.5V x 3 | AA1.5V x 3 | - |
| Category Ratings | CAT III 600V | CAT II 1000V | - |
Note: Accuracy values are typical and may vary. Refer to the full user manual for detailed specifications.
Product Visuals and Diagrams







4. Setup and Pre-operation Check
4.1 Pre-operation Check
- Battery Check: Ensure the battery power is sufficient. A low battery icon will be displayed when power is insufficient.
- Test Lead Inspection: Inspect the test leads for damage, breakage, or poor contact. Do not use damaged accessories.
- Gear Position: Confirm the gear position is correct before measurement to avoid mismatching voltage/current gears.
Unboxing Video
Video demonstrating the unboxing of the FUZRR Digital Multimeter and its included accessories.
5. Operating Instructions
5.1 Basic Measurement Steps
- Voltage Measurement:
- Insert the red test lead into the VΩmA jack and the black test lead into the COM jack.
- Turn the gear to the ACV/DCV position.
- Connect the probes to both ends of the measured load and read the stable data.
- Current Measurement:
- Insert the red lead into the 10A jack and the black lead into the COM jack.
- Series connect the meter into the circuit.
- Select the corresponding AC/DC current gear for measurement.
- Resistance & Continuity Test:
- Select the Ω/continuity gear.
- Power off the tested circuit first.
- Connect probes to both ends of the resistance.
- A buzzer sounds for an on-state circuit, and the resistance value is displayed for resistance measurement.
- NCV Non-contact Detection:
- Turn on the NCV function.
- Hold the meter close to the wire or wall wire slot.
- The meter will alarm and flash to indicate live voltage.
5.2 Common Function Operation
- Data Hold: Press the HOLD key to lock the current measurement data on the screen. Press again to unlock.
- Max Value Lock: Press the MAX key to record and display the maximum measured value in real time.
- Backlight Switch: Short press the backlight key to turn on/off the screen backlight, suitable for dark environment operation.
- Auto Power-off: The meter will automatically shut down after about 15 minutes of no operation to save power.
6. Safety Precautions
- Do not measure voltage higher than the rated range to avoid instrument damage and electric shock accidents.
- Strictly prohibit parallel connection in current measurement gear, which will cause short-circuit burnout of the instrument.
- Please power off the equipment under test before resistance, diode, and capacitance measurement to ensure measurement accuracy and personal safety.
- Do not operate the meter and test leads with wet hands, and avoid using it in rainy and humid environments for a long time.
- Stop using immediately if the instrument is damaged, abnormal display, or abnormal sound occurs, and do not disassemble it privately.
- Keep the instrument away from high temperature, strong magnetic fields, and corrosive substances to avoid affecting measurement accuracy and service life.
7. Maintenance & Storage
- Daily Cleaning: Wipe the body with a dry soft cloth regularly; do not use chemical corrosive cleaning agents.
- Battery Replacement: Replace AA batteries in time when the low battery icon appears. Take out the batteries if not in use for a long time to avoid liquid leakage and corrosion.
- Fuse Replacement: If the internal fuse is blown due to overload, replace it with a fuse of the same specification to ensure safety protection performance.
- Storage Conditions: Store in a dry, ventilated, and dust-free environment. Avoid extrusion and falling impact.
- Regular Calibration: Professional calibration is recommended every 12 months to ensure long-term measurement accuracy.
8. Troubleshooting
For common issues, please refer to the "Safety Precautions" and "Maintenance & Storage" sections. If the multimeter exhibits abnormal behavior not covered in this manual, or if you suspect a malfunction, cease use immediately and contact customer support. Do not attempt to disassemble or repair the device yourself, as this may void the warranty and pose safety risks.
9. User Tips
- Users have praised the excellent build quality and clear display of the multimeter.
- The Non-Contact Voltage (NCV) function is noted for working well and being a useful safety feature.
- Always double-check the model received against your order, as some users have reported receiving the FR15B+ when expecting the FR17B+.
10. Warranty & Support
10.1 Standard Accessories
- 1 × Digital Multimeter (FR15B+ / FR17B+)
- 1 × Pair of Test Leads
- 1 × User Manual
- 1 × Packing Box
10.2 Warranty Statement
We provide a 12-month warranty for quality problems of the product (excluding artificial damage, improper operation, and consumable accessories such as test leads). During the warranty period, free maintenance and replacement services are available for non-human failure under normal use. Please do not disassemble the instrument privately, otherwise, the warranty will be invalid.
For further assistance or to view the complete user manual, please refer to the official PDF document: FUZRR Digital Multimeter User Manual (PDF).