1. Introduction
This manual provides detailed instructions for the APWIKOGER Mini Power Standing Wave Meter. This device is a digital display shortwave power meter designed for measuring power and standing wave ratio (SWR) in the 1.6-50MHz frequency range, with a power measurement capability of 0.5W to 150W. It features high accuracy, multiple display options, and an audible alarm for high SWR conditions.
2. Key Features
- Accurate and Efficient: Utilizes a fitting algorithm based on detection diode characteristics and dual-baseline segmentation for accurate power and SWR measurements (better than ±5% accuracy). High-speed averaging detection provides real-time efficiency display.
- Multiple Display Options: Offers five different interface display options, selectable with a single click, allowing for user customization.
- Audible Alert: Triggers a beep alarm when the standing wave ratio exceeds 2.0, indicating potential issues.
- Open-Source Software Compatibility: Supports G8GYW open-source software code, enabling modification and addition of features. USB firmware upgrade is supported without the need for a special burner.
- Long Battery Life and Multi-Functional Keypad: Built-in rechargeable lithium battery provides over 50 hours of use per charge. The multi-functional keypad offers interactive functionality.
3. Specifications
| Parameter | Value |
|---|---|
| Certification | NONE |
| Origin | Mainland China |
| DIY Supplies | ELECTRICAL |
| Model Number | Display Power Standing Wave Meter |
| Color | Black |
| Frequency Range | 1.6-50MHz |
| Power Measurement Range | 0.5W-150W |
| Standing Wave Measurement Range | 1.0-99.9 |
| Insertion Loss | <0.12dB |
| Insert Standing Wave (1.6-30MHz) | ≤1.02 |
| Insert Standing Wave (30-50MHz) | ≤1.05 |
| Measurement Accuracy | Better than ±5% |
| Impedance | 50Ω |
| Standing Wave Alarm | ≥2.0 (with shutdown function) |
| RF Interface Type | SL16-M or N (default M) |
| Display Content | Forward power, standing wave, antenna end power, efficiency |
| Power Supply | Built-in 3.7V/1000mAh rechargeable lithium battery or USB Type-C |
| Shutdown Power Consumption | <0.1uA |
| Screen Size | 0.96 inches |
| Screen Type | OLED |
| Data Communication | USB Type-C |
| Firmware Upgrade | Support |
| Machine Size (L×W×H) | 88mm × 64mm × 38mm (3.46 × 2.51 × 1.49 inches, excluding protruding parts) |
| Battery Included | No (internal rechargeable battery) |
4. Setup
4.1. Charging the Device
The device comes with a built-in 3.7V/1000mAh rechargeable lithium battery. To charge, connect a USB Type-C cable to the USB 5V port on the front panel. A red light indicates charging, and the light turns off when fully charged.
4.2. Connecting to RF Equipment
The meter uses SL16-M or N type RF interfaces (default is M type). Connect your antenna or RF load to one connector and your radio or transmitter to the other. Ensure connections are secure.
5. Operation
5.1. Power On/Off
- To Power On: Long press the power/function button (labeled ⏻/FN) on the front panel.
- To Power Off: Long press the power/function button.
5.2. Display Interfaces
The device has a total of 5 display interfaces. These interfaces are automatically saved and recalled at the next startup.
- Switching Interfaces: Short press the power/function button to cycle through the different display interfaces.
- Display Content: The OLED screen can show forward power (PWR), standing wave ratio (SWR), antenna end power (ANT), and efficiency (EFF).
5.3. Standing Wave Alarm
The meter features an audible alarm that triggers when the standing wave ratio (SWR) exceeds 2.0. This alarm serves as a warning for potential impedance mismatch issues. Double-click the power/function button to switch the standing wave alarm on or off.
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using harsh chemicals or abrasive materials.
- Power Handling: To prevent damage to the detection components, it is recommended not to exceed 110W for continuous transmission in FM or AM modes. For SSB or CW modes, the device can operate under 200W for extended periods. Exceeding 500W will damage the detection components.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
7. Troubleshooting
- No Display/Device Not Turning On: Ensure the device is fully charged. Connect it to a USB Type-C power source and check the charging indicator.
- Inaccurate Readings: Verify that all RF connections are secure and that the correct RF interface type (SL16-M or N) is being used. Ensure the power input is within the specified range (0.5W-150W).
- Audible Alarm Triggering: If the SWR alarm sounds, it indicates an SWR of 2.0 or higher. Check your antenna system for impedance mismatches or faults. Reduce transmit power if necessary.
- Device Damage: Continuous transmission exceeding 110W in FM/AM, or exceeding 200W in SSB/CW, and especially exceeding 500W, can damage the internal detection components. Always operate within specified power limits.
8. User Tips
- Open-Source Customization: For advanced users, the GM328A's compatibility with G8GYW open-source software allows for modifying the code and adding custom features. This can enhance the device's functionality beyond its default settings.
- Firmware Upgrades: Utilize the USB Type-C port for convenient firmware upgrades, eliminating the need for specialized programming tools. Regularly check for available firmware updates to improve performance or add new features.
9. Warranty and Support
For any technical assistance or support, please contact Universalmall Store, the seller of this product. You may also refer to the official user manual PDF for additional guidance and detailed diagrams. The PDF can be accessed here.