1. Safety Summary
Welcome to use the adjustable program-controlled DC stable voltage power supply (hereinafter referred to as the power supply). Please read this manual carefully, especially the safety information, to prevent personal injury or damage to the power supply and other connected electronic equipment.
This manual contains important safety instructions that must be followed for the operation and storage environment of the adjustable program controlled DC regulator.
Initial Inspection
When you receive a new power supply, perform the following checks:
- Check for any damage caused by transportation.
- Verify that all accessories are complete.
- Before powering on, ensure the product meets your actual input voltage.
- Check if the output voltage and current are normal.
If any problems are found, please contact the dealer immediately.
Safety Symbols
The following safety symbols will appear in the manual or on the machine:
- ⚡ Connect ground signs
- ⚠ High-pressure hazard signs
- ⚠ Note the warning signs
2. Product Overview
The HPS series is a digital display programmable switch DC voltage stabilization supply designed to simultaneously display voltage, current, and power. It is widely used for product aging, R&D testing, school, and production line use. The output voltage and current are continuously adjustable between 0 and nominal values using the encoder knob.
This power supply offers excellent stability and ripple coefficient, along with multiple protection features including short circuit protection, over-pressure protection, over-current protection, and over-temperature protection. It features a beautiful design, convenient operation, and long-term reliability. It is equipped with USB fast charging interfaces and computer PC-terminal software control function, making it popular among users.
Key Features:
- Constant voltage and constant current automatic switching function.
- Preset voltage and current values using a coding switch for convenience.
- Separate power output switch button for easy control.
- Short-circuit protection alarm (OCP) with buzzer sound and OCP indicator.
- Four-digit display for setting voltage, setting current, actual voltage, and actual current.
- Low-noise, temperature-controlled cooling fans for optimal thermal management.

Figure 2.1: Front panel highlighting key features and indicators.

Figure 2.2: Lab-grade accuracy and fast charging capabilities.

Figure 2.3: Multi-layer protection for stable power and smarter safety.
3. Specifications
Product Parameters
- Model Number: HPS series (see product label for details)
- Output voltage: 0-Nominal value voltage is continuously adjustable
- Output current: 0-Nominal value current is continuously adjustable
- Output power: Voltage V * Current A
- Auxiliary function Output: MUTE Settings, OCP short circuit protection, USB fast charging interface, TYPE-C quick charge.
- Input voltage: AC115V±10%, AC230V±10%. The input AC voltage is switched optional.
- Operating temperature: 0°C ~ 40°C; relative humidity: <80%RH
- Storage temperature: -10°C ~ 70°C; relative humidity: <70%RH
Performance Characteristics
- Constant pressure state: Voltage Stability≤0.5% + 3mV, Load Stability≤0.5% + 3mV, Ripple noise≤0.5%A P-P
- Constant current status: Current Stability ≤0.5% + 3mA
- Protection mode: Over-pressure protection, over-current protection, over-temperature protection, short-circuit protection
- Displayed: Four digital tubes for voltage, current, and power
- Display accuracy: 0.5% + 5 words
- Display Resolution: Voltage 0.01V, Current 0.001A (when over 100V: 0.1V, when greater than 10A: 0.01A)
Model List
| Product Model | Output Voltage | Output Current | Output Power |
|---|---|---|---|
| HPS305 | 0-30V | 0-5A | 150W |
| HPS3010 | 0-30V | 0-10A | 300W |
| HPS605 | 0-60V | 0-5A | 300W |
| HPS1203 | 0-120V | 0-3A | 360W |
| HPS3001 | 0-300V | 0-1A | 300W |
Physical Dimensions & Weight
- Product Size: 3.54inch * 5.7inch * 7.48inch
- Package Size: 10.4inch * 5.3inch * 7.67inch
- Product Weight: Net weight: 2.5lb, Gross weight: 3.3lb
4. Panel Description
Front Panel

Figure 4.1: Front Panel Layout and Controls.
- Voltage Display: Shows the voltage setting or output value.
- Current Display: Shows the current setting or output value.
- Output Power Display: Shows the output power.
- C.V Constant Voltage Status Indicator: Lights up when the machine is in constant voltage state.
- C.C Constant Current Status Indicator: Lights up when the machine is in constant current state.
- OCP Short Circuit Indicator: Lights up to indicate OCP function is enabled.
- OUT_InputIndicator: (This seems to be a typo in the source, likely refers to Output Indicator)
- Output Switch: Turns the power output on or off.
- OCP Over-current Protection Key: Toggles the over-current protection function.
- Voltage Coarse Regulation Encoder (V-COARSE): Adjusts the first two digits of the set voltage.
- Voltage Fine Tuning Encoder (V-FINE): Adjusts the last two digits of the set voltage.
- Current Coarse Adjustment Encoder (A-COARSE): Adjusts the first two digits of the set current.
- Current Fine-Tuning Encoder (A-FINE): Adjusts the last two digits of the set current.
- Quick Charge USB Interface (USB-A): Supports USB fast charging up to 18W.
- Quick Charge TYPE-C Interface (USB-C): Supports TYPE-C fast charging up to 18W.
- Positive Output Terminal (+): Connects to the positive pole of the load device.
- Negative Output Terminal (-): Connects to the negative pole of the load device.
- Ground Terminal (GND): Used for grounding.
- Power Switch: Turns the power supply on or off.
Rear Panel

Figure 4.2: Rear Panel Layout.
- Fuse Box: Stores the fuse for easy replacement.
- AC Input Power Outlets: AC power input socket.
- AC Input Voltage Selector Switch: Selects between AC115V or AC230V input.
- Cooling Fan: For chassis heat dissipation; activates when temperature requires.
5. Operating Method
5.1 Power On
Press the POWER button to turn on the power supply. The screen will display the voltage and current values that were set when the machine was turned off last time.
5.2 Voltage Setting
Regardless of whether the power supply is in the output state or not, you can use the "V-COARSE/V-FINE" coding switch to set the voltage. When entering the voltage setting state, the currently set "bit" will be prompted by flashing. Turn clockwise to increase the value and counterclockwise to decrease the value. Press the coding switch to shift to the left. 5 seconds after the voltage setting operation is completed, the flashing stops and the current setting value is stored.
5.3 Current Setting
Regardless of whether the power supply is in the output state or not, you can use the "A-COARSE/A-FINE" coding switch to set the current. When entering the current setting state, the currently set "bit" will be prompted by flashing. Turn clockwise to increase the value and counterclockwise to decrease the value. Press the coding switch to shift to the left. 5 seconds after the current setting operation is completed, the flashing stops and the current setting value is stored.
5.4 Output Switch
Short press the "Output" button on the front panel to switch the power output on or off.
5.5 OCP Short Circuit Protection
Press the "OCP" button to turn on (or off) the OCP short circuit protection alarm function. When OCP is enabled and the external load experiences a short circuit or over-current, the machine will stop output and trigger an alarm. To release the alarm and restore output, short press the "Output" key.
5.6 Connecting Load Equipment
- Rotate counterclockwise to loosen the terminal knob.
- Insert the output wire terminals into the terminal screw according to the positive and negative poles.
- Turn clockwise to tighten the terminal knob.
- Firmly connect the other end of the wire to the positive and negative poles of the load device.
Warning:
Incorrect connection may cause damage to the power supply and the connected load. When connecting a battery load, do not connect the '+' and '-' poles reversely, as this may damage the power supply.
5.7 Constant Voltage/Constant Current Characteristics
This power supply operates with constant voltage/constant current automatic conversion. It automatically switches between constant voltage and constant current states based on the load change. The intersection point between constant voltage and constant current is called the conversion point. For example, if the load makes the power supply work in a constant voltage mode, it outputs a constant voltage. As the load increases, the output voltage remains stable and the output current increases. When the current value reaches the set current limit value, the power supply automatically switches to constant current mode. The output current remains stable, and the output voltage decreases proportionally with the further increase of the load. The conversion between constant voltage and constant current is indicated by the LED on the front panel. The CV indicator light is on when the voltage is constant, and the CC indicator light is on when the current is constant.

Figure 5.1: Constant Voltage/Current Characteristics.
5.8 Demonstration Video
Video 5.1: Demonstration of voltage and current adjustment, and OCP alarm functionality.
6. System Settings
Press and hold the "Output" button for 5 seconds to enter the system setting function. The machine can be set by default according to your needs.
The system default setting items include:
- Power supply output status.
- Screen brightness.
- Buzzer Switch.
After entering the system settings, turn the voltage encoding switch to change the default parameters of the current project. Press the voltage encoding switch to switch to the next item. If you have switched to the last item, click the voltage encoding switch again, and the machine will save the parameters and exit the setting state. If any other key is pressed during the parameter setting process, the setting state will be exited, and the parameter setting will not be saved.
Setting Items and Parameters
| Serial number | Item | Parameter | Meaning | Default Settings |
|---|---|---|---|---|
| 1 | Output default state | 0 | When the power is turned on, the OUT output is turned off by default | 0 |
| 1 | When the power is turned on, the OUT output is turned on by default | |||
| 2 | Screen brightness | 0 | Low brightness | 0 |
| 1 | High brightness | |||
| 3 | Buzzer Switch | 0 | No beeps | 1 |
| 1 | Buzzer Sound |
7. Product Maintenance
General Maintenance
- When the machine is not in use, please disconnect the power supply.
- Unplug the power plug before cleaning the machine.
- Do not use solvents containing hydrocarbons, chlorides, or similar substances, nor detergents containing abrasive ingredients.
Fuse Replacement
If the fuse blows, the machine will stop working. It is necessary to find out and correct the cause of the blown fuse and then replace it with a fuse of the same specification.
High Voltage Danger:
For effective safety protection, only replace the fuse with one of the specific specification. Before replacing the fuse, you must turn off the power and unplug the power cord from the power socket.

Figure 7.1: Fuse replacement procedure.
8. Troubleshooting (Common Problems)
The power supply cannot be turned on
- Check and verify whether the power wire has AC power and whether the fuse is intact.
There is no power output
- Check whether the output button is on.
- Verify that the wire is in good condition.
- Ensure that the voltage or current is adjusted to output.
What is constant voltage mode (C.V)?
The power supply constantly outputs at a voltage set by the user, and the current will be output and supplied according to the actual needs of the load.
What is constant current mode (C.C)?
When the current required by the load exceeds the limit current value set by the user, the power supply will automatically switch to the constant current mode for operation. At this time, the current will remain unchanged, and the voltage will be output and supplied according to the demand of the load.
The power supply cannot be output according to the current value set by the user
The current value set by the user refers to the maximum limit current value allowed to be output by the power supply. The current value of actual output is supplied according to the actual demand of the load, but will not exceed the current limit value set by the user.
The voltage cannot reach the maximum value of this machine
Please determine the input voltage required by the machine: 230V±10% or 115V±10%. There is a voltage switch on the back of the power supply. If you use 110V, you need to turn it to 115V.
Scratches on power supply display
The LED digital display has a protective film to protect it from scratches during transportation. If you feel that the screen is not clear, you can remove the protective film on it.
The fan of the power supply does not work
The exhaust fan is located behind the power supply. In the process of use, when the power supply reaches a certain temperature, it will automatically turn on, instead of always turning on.
9. User Tips
- Always ensure proper grounding to prevent leakage and reduce ripple interference.
- When connecting batteries, double-check polarity to avoid damage.
- For precise voltage and current adjustments, use both coarse and fine tuning knobs.
- Utilize the OCP function to protect your load equipment from short circuits and over-currents.
- Remember to check the input voltage selector switch on the rear panel to match your local power supply (115V or 230V).
10. Warranty & Support
Warranty Service
We provide warranty service for our products within one year from the date of purchase. This warranty does not cover:
- Faults caused by abnormal use, such as improper manual operation, improper repair, modification, or adjustment of devices.
- Consumable materials.
- Damage from natural and irresistible disasters, such as floods, fires, earthquakes, etc.
Additional Resources
For a detailed user manual in PDF format, please refer to the official document: Hangell Adjustable DC Power Supply User Manual (PDF)