1. Product Overview
The DMC03 is a sensorless brushless motor control driver, a dedicated control module designed for the operation of three-phase brushless DC motors without Hall sensors. This module features multiple pre-set operating modes, allowing users to quickly select the appropriate motion profile. Settings for speed, delay, and cycle count are retained even after power loss. It can operate as a standalone module or be integrated with other systems. Simply connect the three-phase wires (U, V, W) to enable motor control.
Applications: Drone motors, water pumps, oil pumps, air pumps, power tools, propellers, and other general industrial control applications. Please note, this product is not intended for use in specialized industries such as medical or firefighting, or in life-critical applications.

Image 1.1: Aideepen ZK-DMC03 BLDC Brushless Sensorless Motor Driver with key features highlighted.
Video 1.1: An overview of the ZK-DMC03 Brushless Motor Controller's features and functions.
2. Package Contents
- Motor driver module x 1
- PH2.0 8-pin terminal cable x 1
3. Specifications
| Feature | Description |
|---|---|
| Model | ZK-DMC03 Sensorless Brushless Motor Control Driver |
| Compatible Motors | Sensorless brushless DC motors |
| Drive Capacity | Maximum RMS 10A |
| Main System Functions | Auto, Manual, Settings, Serial Port Control |
| Operating Voltage | DC 10-30V |
| Continuous Output Power | 300W |
| Acceleration/Deceleration Control | Yes |
| Operating Environment | -5°C to 60°C (non-condensing) |
| Cycle Life | 1-9999 cycles |
| Reverse Polarity Protection | Yes |
| Remote Communication Control | TTL Serial Port |
| Modbus Communication | Yes |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Wireless Functionality | No |
| Battery Included | No |
| High-concerned chemical | None |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Dimensions | 78mm (Length) x 42.7mm (Width) x 52.3mm (Height) |

Image 3.1: Product dimensions of the ZK-DMC03 controller.
4. Setup
4.1 Basic Wiring Diagram
Connect the motor and power supply according to the diagram below. Ensure correct polarity for the power supply.

Image 4.1: Basic wiring diagram showing connections for the motor (U, V, W) and power supply (Positive, Negative).
4.2 Expansion Interface
The module features an 8-pin expansion interface for additional control and output signals.
- Power Expansion Interface: Positive and negative interface for 12V power supply output.
- Two External Triggering Signals: For Start/Stop and Change Direction functions.
- Two Limit Positions: (Limit 1, Limit 2) for motor control.
- Two-channel Output Signal: (Output 1, Output 2) for 0V, using common anode connection for 12V.

Image 4.2: Diagram detailing the Expansion Interface and Communication Interface connections.
4.3 Communication Interface
The module supports TTL Serial Port communication for remote control and Modbus communication.
- 5V: 5V power output.
- TXD: Transmit Data.
- RXD: Receive Data.
- GND: Ground.
4.4 Expansion Port Wiring Example
An example wiring for NPN normally-open proximity switches and normally-activated buttons is shown below.

Image 4.3: Expansion Port Wiring Diagram for NPN proximity switches and normally-activated buttons. Brown wire connects to 12V, blue to GND, black to limit interface X1/X2. Y1 and Y2 are for signal processing or signal lights.
5. Operating Instructions
5.1 Control Panel Overview
The front panel features buttons for forward (CW) and reverse (CCW) rotation, a RUN/STOP button, and an encoder setting knob. Indicators show the current rotation direction.

Image 5.1: Front panel layout with labels for buttons, indicators, and encoder knob.
5.2 Parameter Adjustment
On the operation interface, rotate the encoder to adjust the speed. The CW key is for forward rotation, the CCW key for reverse rotation, and the RUN/STOP key for running, stopping, and exiting. Press and hold the encoder to enter the menu settings.
On the menu settings interface, press the encoder briefly to enter the menu parameter setting state corresponding to F-XX. The parameters flash, then press the shift key briefly again to rotate the encoder to adjust the parameters. Short press the RUN/STOP button to exit the parameter settings and return to the main menu adjustment interface.

Image 5.2: Visual guide for adjusting parameters and exiting the settings menu.
5.3 Menu Setting Functions (F-XX)
The module offers various configurable parameters:
| Serial Number | Function | Adjustable Range | Default Value |
|---|---|---|---|
| F-01 | Action flow mode selection | 1-20 | 1 |
| F-02 | Positive rotation time A (Unit: seconds) | 0 - 43200.0 (12 hours) | 60.0 |
| F-03 | Positive rotation end delay B (Unit: seconds) | 0.1-999 | 10 |
| F-04 | Reversal time C (Unit: seconds) | 0 - 43200.0 (12 hours) | 1600 |
| F-05 | Reverse end delay D (Unit: seconds) | 0.1-999 | 10 |
| F-06 | Number of cycle operations (Unit: times) | 0-9999 or countless times | 1 |
| F-07 | Forward rotation speed (0 - 100%) (Unit: seconds, Accuracy: ±0.2 seconds) | 100% | 0.0 |
| F-08 | Reversal speed (0 - 100%) (Unit: seconds, Accuracy: ±0.2 seconds) | 100% | 0.0 |
| F-09 | Protection current setting (Stop operation when exceeding the set threshold) | 0.00-12.00A | 10.00 |
| F-10 | Main interface display content (00: Motor speed, Number of cycles; 01: Motor speed, Delay time) | 0-1 | 00 |
| F-11 | Actions when pressing the pause button (0: Motor slows down and stops gradually; 1: Motor stops immediately) | 0-1 | 0 |
| F-12 | Acceleration/deceleration levels (1: slowest, 100: fastest) | 1-100 | 20 |
| F-13 | Backlight brightness level | 0-5 | 4 |
| F-14 | Postal Address | 1-255 | 1 |

Image 5.3: Table detailing menu setting functions F-01 to F-09, including adjustable ranges and default values.

Image 5.4: Table detailing menu setting functions F-10 to F-14, including adjustable ranges and default values.
5.4 Action Flow Mode Selection (F-01)
The F-01 parameter allows selection of various pre-programmed action flow modes. Below is an overview of some common modes:
| Serial Number | Action Description |
|---|---|
| [F01]→P01 | Press the button to start in the forward direction, then press the stop button. Operation: Press the [CW] button for forward rotation, and then press the stop button once. Press the [CCW] button for reverse rotation, and then press the stop button once. [run/stop] Start/Stop. |
| [F01]→P02 | Press the button to start rotating clockwise or counter-clockwise, and release it to stop. Abbreviation: Press and hold [CW] continuously to rotate clockwise, press and hold [CCW] continuously to rotate counterclockwise. |
| [F01]→P03 | After pressing the button, it will rotate forward for the set time - with a stop delay or rotate backward for a stop delay. This cycle can be repeated F-6 times. After completion, port O1 will send an activation pulse. Press [RUN/STOP] (triggered by the EN input port) to stop the movement and end the cycle. Operation: Click [CW] for forward rotation - with delay (F-07), click [CCW] for reverse rotation - with delay (F-08). |
| [F01]→P04 | After pressing the button, it will rotate forward for the set time - then stop for a delay - then reverse - and stop for another delay. Operation: Click on [CW] for forward rotation - delay (F-07) - reverse - delay. |
| [F01]→P05 | After the module is powered on, it keeps rotating in the forward direction. [ON/OFF] indicates turning on/off. |
| [F01]→P06 | After the module is powered on, it keeps reversing. [ON/OFF] indicates turning on/off. |
| [F01]→P07 | After the module is powered on, it will rotate forward for time A and then stop for delay time B. This cycle will repeat F times. |
| [F01]→P08 | After the module is powered on, press the time C to reverse - stop delay time D, Repeat F for 06 times. |
| [F01]→P09 | After the module is powered on, it will perform the following operations according to the set times: A - forward rotation - stop delay time; B - reverse rotation time C - stop delay time D - cycle; F - repeat 6 times. |
| [F01]→P10 | After the module is powered on, follow the set time: C for reverse-stop delay time, D for forward rotation time, A for stop delay time, B for cycle, and F for 06 times. |
| [F01]→P11 | After the module is powered on, it starts to rotate in the forward direction after a delay time B - the stop delay cycle begins. |
| [F01]→P12 | After the module is powered on, it starts to reverse after a delay time D - stops the delay and enters a cycle. |
| [F01]→P13 | After the module is powered on, it starts the forward rotation time A after a delay time B - stops for a delay time B - reverses for a time C - stops for a delay time D, and this cycle repeats. |
| [F01]→P14 | After the module is powered on, it starts to reverse after a delay time D - stops for a delay time D - then starts to rotate forward for a time A - stops for a delay time B - and this cycle repeats. |
| [F01]→P15 | After the module is powered on, when it encounters limit 1, it stops for a delay. Then, when it encounters limit 2, it stops for a delay and resumes normal forward rotation in a cycle. |
| [F01]→P16 | IN sends a signal. The motor rotates forward. Once the signal is disconnected, the motor stops. |
| [F01]→P17 | IN sends a signal, and after the delay time, it starts to rotate forward - stops the delay and enters a loop. |
| [F01]→P18 | IN sends a signal, and the forward rotation time A begins after a delay of time B - stop delay time B, then reverse time C - stop delay time D, and this cycle repeats. |
| [F01]→P19 | IN sends a signal. When it encounters limit 1, it stops - with a delay. It then automatically reverses upon encountering another limit. After 2 seconds, it stops again - with a delay. It then resumes rotating in the forward direction and this cycle repeats. |
| [F01]→P20 | IN sends a signal. The motor rotates forward for A seconds and then stops for a delay. Then it sends another signal, causing the motor to rotate in reverse. The delay time is C seconds. The stopping time is given by the signal, and the direction remains unchanged. |
| [F01]→P21 | When IN gives a signal, the motor rotates in the forward direction for a period of time A. Once the signal disappears, the motor reverses. At time C, the rotation stops when the signal disappears. |
| [F01]→P22 | There is a signal, no action occurs, the signal disappears, the motor rotates forward for time A, then stops for time B, and this cycle repeats. |
| [F01]→P23 | The IN signal is present. The motor is rotating clockwise for A seconds and then stops. Or it stops when it encounters a limit switch. The stopping time is B. The motor rotates counterclockwise and stops after C seconds or when it encounters another limit switch. During the stopping time B, if the signal one is triggered, the countdown will be reset. After the motor rotates counterclockwise for C seconds or stops after D seconds, if there is an IN signal immediately, it will rotate clockwise for A seconds and then stop or stop when it encounters the first limit switch. Then the stopping time B will be executed. The motor will stop for C seconds after rotating counterclockwise and then stop after delaying for D seconds or when it encounters the second limit switch (This is for an automatic door. When a person is detected, it opens. After the person leaves, it delays closing. When someone comes, it immediately opens until no one is present and then it closes). Note: When the motor is in operation, the O2 output port is open; when it stops, the O2 output port is closed. |

Image 5.5: Overview of Action Flow Mode Selection [F01]->P01 to [F01]->P04.

Image 5.6: Overview of Action Flow Mode Selection [F01]->P05 to [F01]->P12.

Image 5.7: Overview of Action Flow Mode Selection [F01]->P13 to [F01]->P19.

Image 5.8: Overview of Action Flow Mode Selection [F01]->P20 to [F01]->P23.
6. User Tips
- Always ensure the power supply voltage is within the specified range (DC 10-30V) to prevent damage.
- When connecting the motor, double-check the wiring to avoid incorrect rotation direction or motor issues.
- For applications requiring precise control, familiarize yourself with the various action flow modes (F-01 settings) and parameter adjustments.
- Utilize the Modbus/TTL serial port communication for advanced integration and remote control.
7. Troubleshooting
Refer to the table below for common issues and their solutions:
| Phenomenon | Possible Problem | Solutions |
|---|---|---|
| The screen is not illuminated | The power supply circuit is connected incorrectly or not receiving normal power. | Check the power supply circuit to ensure correct connection and normal power supply. |
| The motor is not rotating | The pulse signal is weak. | Increase the voltage or raise the speed slightly. |
| Overcurrent protection. | Check if the motor load exceeds the controller's protection current. | |
| The motor is not rotating and it keeps vibrating. | Check the wiring of the motor to see if there are any problems. | |
| Motor rotation direction Error | The motor wires are connected incorrectly. | Exchange the positions of the motor wiring. |
| Motor locked rotation / Vibration | Accelerate time is short. | Increase the acceleration time. |
| The motor torque is low. | Choose a high-torque motor. | |
| Low voltage or too small current. | Appropriately increase the voltage or current. |

Image 7.1: Troubleshooting guide for common issues with the ZK-DMC03 controller.
8. Maintenance
To ensure the longevity and optimal performance of your ZK-DMC03 motor driver, please follow these maintenance guidelines:
- Keep Clean: Regularly clean the module to prevent dust and debris accumulation, especially around the heat sink, which can affect heat dissipation. Use a soft, dry cloth.
- Avoid Extreme Conditions: Operate the module within the specified temperature range (-5°C to 60°C) and avoid high humidity or condensing environments.
- Check Connections: Periodically inspect all wiring connections for looseness or corrosion. Secure any loose connections to prevent intermittent operation or damage.
- Power Off Before Adjustments: Always disconnect power before making any wiring changes or physical adjustments to the module or connected components.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Ensure you have your product model number (ZK-DMC03) and purchase details available when seeking support.
A PDF version of this user manual is available for download. Download User Manual (PDF)