Aideepen ZK-DMC03

Rate this product if you’ve used it
Contents

Aideepen ZK-DMC03 BLDC Brushless Sensorless Motor Driver Instruction Manual

Model: ZK-DMC03 | Brand: Aideepen

1. Product Overview

The DMC03 is a sensorless brushless motor control driver, a dedicated control module designed for the operation of three-phase brushless DC motors without Hall sensors. This module features multiple pre-set operating modes, allowing users to quickly select the appropriate motion profile. Settings for speed, delay, and cycle count are retained even after power loss. It can operate as a standalone module or be integrated with other systems. Simply connect the three-phase wires (U, V, W) to enable motor control.

Applications: Drone motors, water pumps, oil pumps, air pumps, power tools, propellers, and other general industrial control applications. Please note, this product is not intended for use in specialized industries such as medical or firefighting, or in life-critical applications.

Aideepen ZK-DMC03 BLDC Brushless Sensorless Motor Driver

Image 1.1: Aideepen ZK-DMC03 BLDC Brushless Sensorless Motor Driver with key features highlighted.

Play video
Watch video online

Video 1.1: An overview of the ZK-DMC03 Brushless Motor Controller's features and functions.

2. Package Contents

  • Motor driver module x 1
  • PH2.0 8-pin terminal cable x 1

3. Specifications

FeatureDescription
ModelZK-DMC03 Sensorless Brushless Motor Control Driver
Compatible MotorsSensorless brushless DC motors
Drive CapacityMaximum RMS 10A
Main System FunctionsAuto, Manual, Settings, Serial Port Control
Operating VoltageDC 10-30V
Continuous Output Power300W
Acceleration/Deceleration ControlYes
Operating Environment-5°C to 60°C (non-condensing)
Cycle Life1-9999 cycles
Reverse Polarity ProtectionYes
Remote Communication ControlTTL Serial Port
Modbus CommunicationYes
EU LVD VoltageLow voltage: Below 50Vac or 75Vdc
Wireless FunctionalityNo
Battery IncludedNo
High-concerned chemicalNone
OriginMainland China
CertificationCE, RoHS
Dimensions78mm (Length) x 42.7mm (Width) x 52.3mm (Height)
Product dimensions of the ZK-DMC03 controller

Image 3.1: Product dimensions of the ZK-DMC03 controller.

4. Setup

4.1 Basic Wiring Diagram

Connect the motor and power supply according to the diagram below. Ensure correct polarity for the power supply.

Product Wiring Diagram for ZK-DMC03

Image 4.1: Basic wiring diagram showing connections for the motor (U, V, W) and power supply (Positive, Negative).

4.2 Expansion Interface

The module features an 8-pin expansion interface for additional control and output signals.

  • Power Expansion Interface: Positive and negative interface for 12V power supply output.
  • Two External Triggering Signals: For Start/Stop and Change Direction functions.
  • Two Limit Positions: (Limit 1, Limit 2) for motor control.
  • Two-channel Output Signal: (Output 1, Output 2) for 0V, using common anode connection for 12V.
Expansion Interface and Communication Interface details

Image 4.2: Diagram detailing the Expansion Interface and Communication Interface connections.

4.3 Communication Interface

The module supports TTL Serial Port communication for remote control and Modbus communication.

  • 5V: 5V power output.
  • TXD: Transmit Data.
  • RXD: Receive Data.
  • GND: Ground.

4.4 Expansion Port Wiring Example

An example wiring for NPN normally-open proximity switches and normally-activated buttons is shown below.

Expansion Port Wiring Diagram with NPN proximity switches

Image 4.3: Expansion Port Wiring Diagram for NPN proximity switches and normally-activated buttons. Brown wire connects to 12V, blue to GND, black to limit interface X1/X2. Y1 and Y2 are for signal processing or signal lights.

5. Operating Instructions

5.1 Control Panel Overview

The front panel features buttons for forward (CW) and reverse (CCW) rotation, a RUN/STOP button, and an encoder setting knob. Indicators show the current rotation direction.

Front panel layout of ZK-DMC03

Image 5.1: Front panel layout with labels for buttons, indicators, and encoder knob.

5.2 Parameter Adjustment

On the operation interface, rotate the encoder to adjust the speed. The CW key is for forward rotation, the CCW key for reverse rotation, and the RUN/STOP key for running, stopping, and exiting. Press and hold the encoder to enter the menu settings.

On the menu settings interface, press the encoder briefly to enter the menu parameter setting state corresponding to F-XX. The parameters flash, then press the shift key briefly again to rotate the encoder to adjust the parameters. Short press the RUN/STOP button to exit the parameter settings and return to the main menu adjustment interface.

Adjustment parameters and exit parameter settings

Image 5.2: Visual guide for adjusting parameters and exiting the settings menu.

5.3 Menu Setting Functions (F-XX)

The module offers various configurable parameters:

Serial NumberFunctionAdjustable RangeDefault Value
F-01Action flow mode selection1-201
F-02Positive rotation time A (Unit: seconds)0 - 43200.0 (12 hours)60.0
F-03Positive rotation end delay B (Unit: seconds)0.1-99910
F-04Reversal time C (Unit: seconds)0 - 43200.0 (12 hours)1600
F-05Reverse end delay D (Unit: seconds)0.1-99910
F-06Number of cycle operations (Unit: times)0-9999 or countless times1
F-07Forward rotation speed (0 - 100%) (Unit: seconds, Accuracy: ±0.2 seconds)100%0.0
F-08Reversal speed (0 - 100%) (Unit: seconds, Accuracy: ±0.2 seconds)100%0.0
F-09Protection current setting (Stop operation when exceeding the set threshold)0.00-12.00A10.00
F-10Main interface display content (00: Motor speed, Number of cycles; 01: Motor speed, Delay time)0-100
F-11Actions when pressing the pause button (0: Motor slows down and stops gradually; 1: Motor stops immediately)0-10
F-12Acceleration/deceleration levels (1: slowest, 100: fastest)1-10020
F-13Backlight brightness level0-54
F-14Postal Address1-2551
Table of Menu Setting Functions F-01 to F-09

Image 5.3: Table detailing menu setting functions F-01 to F-09, including adjustable ranges and default values.

Table of Menu Setting Functions F-10 to F-14

Image 5.4: Table detailing menu setting functions F-10 to F-14, including adjustable ranges and default values.

5.4 Action Flow Mode Selection (F-01)

The F-01 parameter allows selection of various pre-programmed action flow modes. Below is an overview of some common modes:

Serial NumberAction Description
[F01]→P01Press the button to start in the forward direction, then press the stop button. Operation: Press the [CW] button for forward rotation, and then press the stop button once. Press the [CCW] button for reverse rotation, and then press the stop button once. [run/stop] Start/Stop.
[F01]→P02Press the button to start rotating clockwise or counter-clockwise, and release it to stop. Abbreviation: Press and hold [CW] continuously to rotate clockwise, press and hold [CCW] continuously to rotate counterclockwise.
[F01]→P03After pressing the button, it will rotate forward for the set time - with a stop delay or rotate backward for a stop delay. This cycle can be repeated F-6 times. After completion, port O1 will send an activation pulse. Press [RUN/STOP] (triggered by the EN input port) to stop the movement and end the cycle. Operation: Click [CW] for forward rotation - with delay (F-07), click [CCW] for reverse rotation - with delay (F-08).
[F01]→P04After pressing the button, it will rotate forward for the set time - then stop for a delay - then reverse - and stop for another delay. Operation: Click on [CW] for forward rotation - delay (F-07) - reverse - delay.
[F01]→P05After the module is powered on, it keeps rotating in the forward direction. [ON/OFF] indicates turning on/off.
[F01]→P06After the module is powered on, it keeps reversing. [ON/OFF] indicates turning on/off.
[F01]→P07After the module is powered on, it will rotate forward for time A and then stop for delay time B. This cycle will repeat F times.
[F01]→P08After the module is powered on, press the time C to reverse - stop delay time D, Repeat F for 06 times.
[F01]→P09After the module is powered on, it will perform the following operations according to the set times: A - forward rotation - stop delay time; B - reverse rotation time C - stop delay time D - cycle; F - repeat 6 times.
[F01]→P10After the module is powered on, follow the set time: C for reverse-stop delay time, D for forward rotation time, A for stop delay time, B for cycle, and F for 06 times.
[F01]→P11After the module is powered on, it starts to rotate in the forward direction after a delay time B - the stop delay cycle begins.
[F01]→P12After the module is powered on, it starts to reverse after a delay time D - stops the delay and enters a cycle.
[F01]→P13After the module is powered on, it starts the forward rotation time A after a delay time B - stops for a delay time B - reverses for a time C - stops for a delay time D, and this cycle repeats.
[F01]→P14After the module is powered on, it starts to reverse after a delay time D - stops for a delay time D - then starts to rotate forward for a time A - stops for a delay time B - and this cycle repeats.
[F01]→P15After the module is powered on, when it encounters limit 1, it stops for a delay. Then, when it encounters limit 2, it stops for a delay and resumes normal forward rotation in a cycle.
[F01]→P16IN sends a signal. The motor rotates forward. Once the signal is disconnected, the motor stops.
[F01]→P17IN sends a signal, and after the delay time, it starts to rotate forward - stops the delay and enters a loop.
[F01]→P18IN sends a signal, and the forward rotation time A begins after a delay of time B - stop delay time B, then reverse time C - stop delay time D, and this cycle repeats.
[F01]→P19IN sends a signal. When it encounters limit 1, it stops - with a delay. It then automatically reverses upon encountering another limit. After 2 seconds, it stops again - with a delay. It then resumes rotating in the forward direction and this cycle repeats.
[F01]→P20IN sends a signal. The motor rotates forward for A seconds and then stops for a delay. Then it sends another signal, causing the motor to rotate in reverse. The delay time is C seconds. The stopping time is given by the signal, and the direction remains unchanged.
[F01]→P21When IN gives a signal, the motor rotates in the forward direction for a period of time A. Once the signal disappears, the motor reverses. At time C, the rotation stops when the signal disappears.
[F01]→P22There is a signal, no action occurs, the signal disappears, the motor rotates forward for time A, then stops for time B, and this cycle repeats.
[F01]→P23The IN signal is present. The motor is rotating clockwise for A seconds and then stops. Or it stops when it encounters a limit switch. The stopping time is B. The motor rotates counterclockwise and stops after C seconds or when it encounters another limit switch. During the stopping time B, if the signal one is triggered, the countdown will be reset. After the motor rotates counterclockwise for C seconds or stops after D seconds, if there is an IN signal immediately, it will rotate clockwise for A seconds and then stop or stop when it encounters the first limit switch. Then the stopping time B will be executed. The motor will stop for C seconds after rotating counterclockwise and then stop after delaying for D seconds or when it encounters the second limit switch (This is for an automatic door. When a person is detected, it opens. After the person leaves, it delays closing. When someone comes, it immediately opens until no one is present and then it closes). Note: When the motor is in operation, the O2 output port is open; when it stops, the O2 output port is closed.
Table of Action Flow Mode Selection F01-P01 to F01-P04

Image 5.5: Overview of Action Flow Mode Selection [F01]->P01 to [F01]->P04.

Table of Action Flow Mode Selection F01-P05 to F01-P12

Image 5.6: Overview of Action Flow Mode Selection [F01]->P05 to [F01]->P12.

Table of Action Flow Mode Selection F01-P13 to F01-P19

Image 5.7: Overview of Action Flow Mode Selection [F01]->P13 to [F01]->P19.

Table of Action Flow Mode Selection F01-P20 to F01-P23

Image 5.8: Overview of Action Flow Mode Selection [F01]->P20 to [F01]->P23.

6. User Tips

  • Always ensure the power supply voltage is within the specified range (DC 10-30V) to prevent damage.
  • When connecting the motor, double-check the wiring to avoid incorrect rotation direction or motor issues.
  • For applications requiring precise control, familiarize yourself with the various action flow modes (F-01 settings) and parameter adjustments.
  • Utilize the Modbus/TTL serial port communication for advanced integration and remote control.

7. Troubleshooting

Refer to the table below for common issues and their solutions:

PhenomenonPossible ProblemSolutions
The screen is not illuminatedThe power supply circuit is connected incorrectly or not receiving normal power.Check the power supply circuit to ensure correct connection and normal power supply.
The motor is not rotatingThe pulse signal is weak.Increase the voltage or raise the speed slightly.
Overcurrent protection.Check if the motor load exceeds the controller's protection current.
The motor is not rotating and it keeps vibrating.Check the wiring of the motor to see if there are any problems.
Motor rotation direction ErrorThe motor wires are connected incorrectly.Exchange the positions of the motor wiring.
Motor locked rotation / VibrationAccelerate time is short.Increase the acceleration time.
The motor torque is low.Choose a high-torque motor.
Low voltage or too small current.Appropriately increase the voltage or current.
Troubleshooting table for ZK-DMC03

Image 7.1: Troubleshooting guide for common issues with the ZK-DMC03 controller.

8. Maintenance

To ensure the longevity and optimal performance of your ZK-DMC03 motor driver, please follow these maintenance guidelines:

  • Keep Clean: Regularly clean the module to prevent dust and debris accumulation, especially around the heat sink, which can affect heat dissipation. Use a soft, dry cloth.
  • Avoid Extreme Conditions: Operate the module within the specified temperature range (-5°C to 60°C) and avoid high humidity or condensing environments.
  • Check Connections: Periodically inspect all wiring connections for looseness or corrosion. Secure any loose connections to prevent intermittent operation or damage.
  • Power Off Before Adjustments: Always disconnect power before making any wiring changes or physical adjustments to the module or connected components.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Ensure you have your product model number (ZK-DMC03) and purchase details available when seeking support.

A PDF version of this user manual is available for download. Download User Manual (PDF)