Myoslim Portable 2 IN 1 Diode Pico Laser Machine

Contents

Professional 5000W Soprano Diode Laser Hair Removal and Picosecond Laser Device

Model: Portable 2 IN 1 Diode Pico Laser Machine

Brand: Myoslim

1. Introduction

This 2-in-1 multifunctional beauty device integrates 808nm diode laser hair removal, picosecond laser, DPL precise light therapy, and RF radiofrequency anti-aging in one machine. It provides an all-around solution for various beauty treatments, including hair removal, freckle reduction, tattoo removal, skin rejuvenation, and skin tightening. This device is designed to offer diverse treatment options for clients, saving space and lowering equipment investment for beauty salons and clinics.

The device features advanced freezing painless technology for hair removal, eliminating burning and stinging sensations. It supports treatment on multiple body areas, including hands, legs, underarms, face, and bikini line. The picosecond laser technology utilizes a photoacoustic effect to shatter pigment clusters, allowing for safe and precise removal of tattoos, moles, freckles, sun spots, and acne scars without scarring.

Professional 5000W Soprano Diode Laser Hair Removal and Picosecond Laser Device with 10 bars and 60 million shots warranty.

Figure 1.1: Professional 5000W Soprano Diode Laser Hair Removal and Picosecond Laser Device.

2. Safety Information

2.1. Contraindications

Treatment with this device is not recommended for individuals with the following conditions:

  • Cancer, especially skin cancer.
  • Pregnancy (including IVF).
  • Use of photosensitive drugs and traditional Chinese medicine.
  • Conditions susceptible to irritation at 808 nm wavelength.
  • Exposure to the sun or sunbathing for 3 to 4 weeks prior to treatment.
  • Active inflammation or herpes simplex infection in the treatment area.
  • History of keloids.
  • Diabetes (relying on insulin injections).
  • Dry and Sensitive Skin.
  • Endocrine disorders (stimulation from bright light).
  • Anticoagulant use.
  • Epilepsy.
  • History of blood clotting.

2.2. Possible Side Effects of Treatment

The 808 Freezing Point Hair Removal System, like other laser technology products, may cause some side effects. These are generally manageable but require attention:

  • Discomfort: Some patients may experience a sensation similar to being bitten, a rubber band snapping, or a burning sensation during treatment. Topical anesthesia may be required for some individuals.
  • Damage to skin texture: In some cases, induration or blisters may develop on the skin surface, requiring wound protection.
  • Pigmentation Changes: Skin pigmentation in the treated area may change (hyperpigmentation or hypopigmentation), especially for skin types IV-VI or with sun exposure before/after treatment. These changes usually fade within three to six months.
  • Scarring: Scarring is rare, but hypertrophic scars or keloids can occur. Following pre- and post-operative guidelines reduces this risk.
  • Excessive Edema: Temporary swelling may occur, typically subsiding within hours to days.
  • Fragile Skin: The treated skin may become fragile after surgery. Avoid makeup and rubbing.
  • Bruises: Purple bruises may appear, lasting from a few days to a few weeks.

2.3. Vision Safety

  • All personnel in the treatment room, including patients and operators, must wear protective eyewear (optical density at 5 (OD>5)).
  • Patients should keep their eyes closed during treatment, even with glasses.
  • If the patient cannot wear glasses, an eye patch should be used to completely block light.
  • If treating an area close to the eye (e.g., eyelid), protect the eye with a corneal plate.
  • Avoid looking directly at the laser light or reflective surfaces from the handpiece, even with eye protection.
  • Set the system to standby mode during pauses to prevent inadvertent laser firing.
  • Press the foot switch and handpiece trigger only when the beam is aimed at the treated skin area.

2.4. Fire Safety

  • Remove hair from the treated area. Place sterile water-soaked gauze near the treated area if necessary.
  • Ensure a fire extinguisher is readily accessible.
  • Avoid using flammable paper products or ensure they evaporate before laser/light exposure.
  • Do not use the system in the presence of flammable materials or anesthetics.
  • Oxygen tubing must be laser safe.

3. Product Overview

3.1. Components and Accessories

The device comes with the following main components and accessories:

  • Main Device Unit with Touch Screen Interface
  • Diode Laser Handle (10-bar, 4 wavelengths: 755nm, 808nm, 940nm, 1064nm)
  • Picosecond Laser Handle
  • Magnetic Spot Size Attachments for Diode Laser Handle (for large, small, and nose areas)
  • Picosecond Laser Treatment Heads (532nm, Non-invasive 532nm, 1064nm, Non-invasive 1064nm, 1320nm)
  • Power Cables
  • Protective Eyewear
  • Foot Switch
  • Water Funnel and Tube
Packaging list showing the main device, diode laser handle, picosecond laser handle, various treatment heads, power cables, and accessories.

Figure 3.1: Packaging List.

2-in-1 laser device with diode laser handle, picosecond laser handle, and various treatment heads.

Figure 3.2: Device with Handles and Accessories.

Picosecond laser handle with five interchangeable treatment heads for different wavelengths.

Figure 3.3: Picosecond Laser Handle with Treatment Heads.

Diode laser handle with three magnetic spot size attachments for different treatment areas.

Figure 3.4: Diode Laser Handle with Magnetic Spot Size Attachments.

3.2. Key Features

  • 2-in-1 Multifunctional Design: Combines diode laser and picosecond laser for comprehensive treatments.
  • Quadruple Wavelength Diode Laser: 755nm, 808nm, 940nm, 1064nm for effective hair removal on all skin types.
  • Picosecond Laser Technology: Targets various skin pigments and conditions, including tattoos, moles, freckles, acne scars, and stretch marks.
  • Painless & Comfortable: Advanced freezing technology minimizes discomfort and ensures a comfortable treatment experience with minimal skin damage and no downtime.
  • High Energy & Fast: Powerful energy output ensures fast and long-lasting results. The 10-bar diode laser handle provides higher output and more stable energy delivery compared to 6-bar handles, leading to faster treatment speeds and better coverage.
  • Easy Operation: Intuitive touch screen interface and LCD screen on the diode laser handle for convenient control.
  • Intelligent Safety System: Built-in safety mechanisms prevent abnormal energy output and protect users.
  • Versatile Use: Suitable for facial, body, and intimate area treatments, ideal for beauty salons and skin clinics.

4. Setup

4.1. Initial Preparation

  1. Add Water: The 808nm freezing point hair removal instrument requires specific water quality. It is recommended to use deionized water or pure water. Tap water or mineral water cannot be used.
  2. Connect Power Cord: Check the input voltage (110V or 220V) and connect the power cord correctly. Incorrect connection can damage the device.
  3. Turn on Air Switch: Locate and turn on the air switch on the device.
  4. Turn on Key Switch: After three seconds, the machine will enter the boot interface. Turn on the key switch to proceed.
Rear view of the 2-in-1 laser hair removal and picosecond laser device showing cooling fans and power input.

Figure 4.1: Rear View with Power Input and Air Switch.

5. Operating Instructions

5.1. Hair Removal Principles

808 Freezing Point Hair Removal operates on the principle of selective photothermodynamics. By adjusting laser wavelength, energy, and pulse width, light energy penetrates the skin to reach hair follicles, where it is absorbed and converted into heat. This heat destroys the hair follicle tissue, preventing regeneration. The unique freezing protection cools the epidermis to 5°C, ensuring a painless and comfortable experience while overcoming the shortcomings of traditional IPL methods.

Diagram illustrating the diode laser working principle: laser energy targeting hair follicles.

Figure 5.1: Diode Laser Hair Removal Principle.

Hair removal is most effective during the hair's growth phase (anagen). The hair growth cycle has three phases: growth phase, catagen phase, and resting phase. Only during the growth phase can the hair follicle pigment fully absorb heat energy, making the follicle most fragile and treatment most effective.

5.2. Picosecond Laser Principles

The picosecond laser uses a photoacoustic effect. High-intensity laser light penetrates the epidermis to reach pigment clusters in the dermis. Due to its short action time and extremely high energy, pigment clusters rapidly expand and explode upon absorbing the high energy. These shattered pigment particles are then swallowed by macrophages, excreted, and the pigment gradually fades and disappears.

Diagram illustrating the picosecond laser working principle: melanin granules absorbing laser energy and being blasted.

Figure 5.2: Picosecond Laser Working Principle.

5.3. General Operation Process

  1. Consultation: Conduct a one-on-one consultation to discuss hair problems and formulate a personalized treatment plan.
  2. Skin Confirmation: The beautician will confirm skin condition, hair texture, and hair volume to determine the treatment plan.
  3. Apply Cold Gel: Cleanse the treatment area and apply a cold gel with hair-controlling ingredients.
  4. Irradiation: Customers wear goggles. The operator irradiates the area painlessly for approximately 3 minutes.
  5. Cool Down: Wipe off the cold gel and apply a cooling pack to the skin.
  6. Calming: Apply calming and moisturizing beauty essence to gently care for the skin after treatment.

5.4. Interface Navigation and Settings

The device features a user-friendly touch screen interface. The diode laser handle also has a small LCD touch screen for direct control.

Diode laser handle with a small LCD touch screen for direct control.

Figure 5.3: Diode Laser Handle LCD Screen.

From the main screen, you can select different body areas and skin colors (Fitzpatrick I-VI) to adjust treatment parameters. The device offers three modes for the diode laser handle and allows adjustment of pulse width, frequency, and energy. For the picosecond laser, you can choose from different wavelengths (532nm, 755nm, 1064nm) and adjust energy and frequency.

Video 5.1: Product demonstration video. This video provides a visual guide to the device's operation, including navigating the touch screen interface, selecting treatment modes, and demonstrating the effectiveness of both the diode laser and picosecond laser handles on various materials.

6. Treatment Parameters

The 808 Freezing Point Hair Removal System presets are based on conclusions obtained by experienced users. Users can also choose and set parameter values themselves. Key parameters include skin color type, laser energy density, and repetition frequency.

During treatment, frequency and pulse width are adjusted according to the client's sensitivity and skin color. For fairer skin, a higher frequency and lower pulse width are used. For darker skin, a lower frequency and higher pulse width are used. The energy density should be kept between 60 J/cm² and 80 J/cm², then adjusted according to skin sensitivity.

6.2. Cumulative Total Energy (KJ) per Square Centimeter

Body Part Treatment Area (grid) Cumulative Energy (J)
Upper Arm8-1050000-80000
Forearm6-840000-60000
Thigh11-13650000-100000
Calf0-1260000-90000
Chest and Abdomen12-1475000-110000
Bikini Line16000-8000
Armpit16000-8000
The Back12-1475000-110000

Table 6.1: Recommended Cumulative Energy per Body Part.

7. Maintenance

7.1. Cooling Technology

The device incorporates cooling technology before, during, and after treatment to protect the epidermis and lower skin temperature, reducing patient discomfort. Cooling is crucial for maximizing healing energy without increasing side effects.

7.2. Post-operative Care

  • Immediately after treatment, use cold (but not frozen) ice packs to cool the treated area and reduce edema and discomfort. Cooled 10x10cm soaked gauze can also be used.
  • Prevent trauma within 4-5 days post-operation: avoid hot baths, strenuous exercise, and massage.
  • Sun Exposure: Apply high-index sunscreen (SPF>30) and avoid direct sunlight on the treated area for at least one month after surgery to prevent melanin regeneration and hyperpigmentation.
  • Makeup: Makeup can be worn after surgery unless blisters or scabs develop. Be gentle when removing makeup to avoid skin damage and infection.
  • Contact with Dirt: If the treated area comes into contact with dirt, apply topical treatment for 10 days. Avoid strenuous activities until normal.

7.3. Follow-up

  • Patients should be checked and receive further treatment within 6-8 weeks after surgery. This period may vary based on treatment outcome and individual hair growth cycle.
  • If no further treatment is required, re-examine the patient after 3-4 months or if hair regrowth occurs.
  • If partial hair removal occurs, re-examine the patient.

8. Troubleshooting

Error # Protection Possible Causes and Troubleshooting Methods
Temp error Control board temperature alarm 1. Temperature too high; 2. Control board fan not working; 3. Temperature sensor or wire broken.
Temp2 error Room temperature alarm 1. Room temperature too high (above 28°C); 2. Temperature sensor or wire broken.
Flow error Water flow alarm 1. Insufficient water flow (low pump pressure, thin water pipe); 2. Water pipe resistance too high.
Level error Water tank level alarm 1. Water tank not filled enough; 2. Water level switch stuck.
Handle does not shine Macro channel/Non channel 1. Visually inspect laser for light emission; 2. Handle button not popping up; 3. Control board wiring stuck; 4. Pedal connection issue.
Blue screen Display screen 1. Screen flooded; 2. Heavy object crushes screen; 3. Screen problems.
TEC not cooling TEC 1. TEC refrigeration chip broken; 2. Check relays in the case.
Machine trip Line 1. Air switch lines do not correspond; 2. Positive/negative lines.

9. Specifications

Attribute Value
Voltage110V/220V (50/60Hz)
Lamp Head TypeMetal
Efficacy Principle of EpilatorLaser/IPL/Radio Frequency
Number of Lamp Heads1 (Diode Laser Handle)
MaterialMetal + ABS
Power TypeElectric
UseBODY, Underarm, Bikini, Whole Face
Skin-Friendly FeatureEpidermal cooling protection minimizes thermal damage risk, with no significant post-treatment redness
Versatile UseSuitable for facial, body, and intimate area treatments, ideal for beauty salons and skin clinics
Smart Safety SystemBuilt-in safety mechanisms prevent abnormal energy output to protect users
Efficient Hair RemovalStable 808 laser energy with a large treatment spot for faster sessions
Ice-Cool & PainlessThe hair removal handpiece has built-in cooling technology for pain-free treatment
Form FactorDesktop/portable integrated design
Host ControlsEquipped with emergency stop button, power switch, and adjustment knobs for safe and convenient operation
Feature2 IN 1, Painless, Portable, High Energy, No Skin Damage
ApplicationFor Beauty Salon, Home Use, Spa
Suitable Skin TypeAll Skin Types (Fitzpatrick I-VI)
Cooling SystemSapphire Contact Cooling
Screen TypeTouch Screen
Plug TypeUS / UK / EU / AU / KR / JP
Wavelength808nm (Optional 755+808+1064nm)
FunctionHair Removal, Tattoo Removal, Pigment Removal, Skin Rejuvenation, Mole Removal, Freckle Removal, Acne Scar Removal, Stretch Mark Removal
Laser TypeDiode Laser + Picosecond Laser
CertificationCE ROHS, RoHs, CE, RoHS
Item TypeLaser Beauty Machine, Epilator

10. Warranty and Support

The device comes with a 1-year warranty. Myoslim provides lifetime technical support and 24-hour online service, including instructional operation video training. Our dedicated team is always available to address any issues promptly.

10.1. Quality Assurance

Every machine undergoes rigorous pre-shipment quality inspections to ensure it meets stringent standards. We are committed to delivering excellence on a global scale.

10.2. Custom Solutions & Expert Support

As a direct factory supplier, we offer flexible ODM/OEM services, including custom logos and multilingual configurations. Comprehensive user manuals and video training materials are provided. Our responsive online support team is available to guide you through setup and operation, making it easy to master your new tools quickly.

11. User Tips

  • For professional use in a beauty salon, the 2-in-1 functionality is highly beneficial, allowing for a wide range of treatments (hair removal, tattoo removal, skin rejuvenation) with a single device.
  • The picosecond laser handle with its five different treatment heads offers versatility for various pigment and skin repair needs, including precise nose hair trimming.
  • The 10-bar diode laser handle provides superior performance, efficiency, and durability compared to 6-bar alternatives, making it ideal for high-volume professional environments.
  • Always ensure the water tank is filled with pure or deionized water and changed monthly to maintain optimal device performance and cooling.
  • Regularly check the TEC cooling system and ensure proper room temperature (5°C to 28°C) to prevent overheating or freezing, which can impact treatment effectiveness and device longevity.
  • The device supports both 110V and 220V power, ensuring compatibility with different electrical systems.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.