1. Introduction
The BOAYAL G161-LCD is a versatile 3-in-1 measurement tool combining a laser distance meter, a digital angle ruler, and a digital level. Designed for both professionals and DIY enthusiasts, it offers multiple measurement modes, high accuracy, and a durable, portable design. This manual provides detailed instructions for its operation and maintenance.
Video: Product demonstration showcasing the G161-LCD's features and applications.
2. Product Overview
2.1. Appearance Description
Familiarize yourself with the components of your G161-LCD device:

Figure 1: Front and top view of the G161-LCD with labeled parts.
- Liquid Crystal Display (LCD)
- Power On/Off Button
- Function Mode Key (FUNC SET)
- Measurement Key (MEAS)
- Laser Receiving Window
- Laser Emission Hole
- Type-C Charging Port
2.2. Key Features
- 3-in-1 Functionality: Laser Distance Meter, Digital Angle Ruler, Digital Level.
- Clear LCD Display: Backlit for easy reading in various lighting conditions.
- Multiple Measurement Modes: Single, Continuous, Area, Volume, Pythagorean, Angle Ruler, Horizontal Bubble, Tape Pattern.
- Unit Switching: Supports meters (m), feet (ft), inches (in), feet/inches (′″), centimeters (cm), and millimeters (mm).
- Durable Design: Sturdy ABS shell with shockproof and durable silicone keys, dustproof, waterproof, and anti-drop.
- Magnetic Attraction: Magnets on the back and bottom for convenient attachment to metal surfaces.
- Rechargeable Battery: 1000mAh built-in lithium battery with Type-C charging.
- Data Storage: Stores up to 100 groups of measurement data.
- Automatic Shutdown: Laser turns off after 20 seconds, screen after 180 seconds, and device after 3 minutes of inactivity to save power.
3. Setup and Basic Operation
3.1. Power On/Off
- To Power On: Long press the Power On/Off button (
). The power-on screen will display the current battery level, angle, and base setting. - To Power Off: Long press the Power On/Off button (
) again.
3.2. Function Selection
After powering on, press the FUNC SET key to enter the function switch menu. Use the left/right arrow keys or MEAS key to select a function, then press FUNC SET to confirm and enter the corresponding function interface.

Figure 2: Function menu with icons for different measurement modes.
3.3. Unit Switching
To switch measurement units (m, ft, in, ′″, cm, mm), short press the FUNC SET key repeatedly while in the unit selection menu. To exit, short press the Power On/Off button.

Figure 3: Steps for switching measurement units.
3.4. Reference Switching
The device can measure from the front or back base. Short press the FUNC SET key to toggle between front and back reference. To exit, short press the Power On/Off button.
3.5. Sound Switch
To turn the sound on or off, short press the FUNC SET key in the sound setting menu. Short press the Power On/Off button to exit.
3.6. Screen Direction Switching
To enable or disable automatic screen rotation, short press the FUNC SET key in the screen direction setting menu. Short press the Power On/Off button to exit.
3.7. Time Delay Measurement
To set a measurement delay (e.g., 3 or 5 seconds), short press the FUNC SET key in the time delay measurement setting. This allows for stable measurements without pressing the MEAS key during the actual measurement. Short press the Power On/Off button to exit.

Figure 4: Delay function settings and example of measurement after delay.
3.8. Angle Calibration
To calibrate the angle, place the instrument as shown in the figure (refer to the manual's page 20 for visual guidance). After a "drop" sound, the screen will display "1", indicating successful calibration. Press FUNC SET to continue to the next angle calibration. The calibration will automatically exit after completing all 4 surfaces. Short press the Power On/Off button to exit calibration at any time.
4. Operating Modes
4.1. Single Measurement (Length)
Short press the MEAS key to turn on the laser point. Aim the laser at the target to be measured, then press MEAS again to trigger a single measurement. The result will be immediately displayed.

Figure 5: Single measurement operation.
4.2. Continuous Measurement (Length Scan)
Long press the MEAS key to enter continuous measurement mode. Move the instrument to measure. The screen will display MAX (maximum value) and MIN (minimum value) readings. Short press any button to stop. A 30-second countdown is active; measurement stops automatically when it ends.

Figure 6: Continuous measurement in progress.
4.3. Area Measurement
In Area Measurement mode, short press MEAS to activate the laser. Aim at the first point, press MEAS. Aim at the second point, press MEAS. The device will measure length and width, then automatically calculate and display the area.

Figure 7: Area measurement process.
4.4. Volume Measurement
In Volume Measurement mode, short press MEAS to activate the laser. Aim at three different points (length, width, height), pressing MEAS after each. The device will automatically calculate and display the volume.

Figure 8: Volume measurement process.
4.5. Pythagorean Theorem Measurement
In Pythagorean mode, short press MEAS to activate the laser. Measure the required sides (hypotenuse and one leg) by aiming and pressing MEAS. The device will automatically calculate and display the unknown side.

Figure 9: Pythagorean theorem measurement example.
4.6. Angle Ruler Mode
Switch to Angle Ruler mode. Stand the instrument on the surface to be measured. It will directly display the tilt angle value.

Figure 10: Angle ruler mode measuring a slope.
4.7. Horizontal Bubble Mode (Digital Level)
Switch to Electron Bubble mode. Lay the instrument flat on a surface. It will function as an electronic horizontal bubble, displaying X and Y axis angles for precise leveling.

Figure 11: Horizontal bubble mode for leveling.
4.8. Tape Pattern Mode
In Tape Pattern mode, the laser is automatically turned on. Point the laser at the measured surface, move the instrument, and the screen will display the measurement value in real-time (default post-baseline).

Figure 12: Tape pattern mode for continuous measurement.
4.9. Backlight Mode
Switch to Backlight mode to adjust the screen backlight for indoor or outdoor use. The indoor light setting is strong, while the outdoor setting provides a brighter field of view.
5. Data Management
5.1. Data Storage
The device can store up to 100 groups of measurement data, allowing for easy review at any time.

Figure 13: Data storage display.
5.2. Storage Function (Review/Delete)
Short press FUNC SET to enter storage mode. Use FUNC SET and MEAS to navigate through pages. Short press the Power On/Off button to delete the current page. Long press the Power On/Off button to exit storage mode.
6. Specifications
| Parameter | Value |
|---|---|
| Product Name | Angle Ruler + Laser Distance Meter |
| Product Model | G161 |
| Angle Range | -90° ~ 90° |
| Angle Measurement Accuracy (Inclinometer Mode) | ±0.4° |
| Angle Resolution (Inclinometer Mode) | 0.01° |
| Ranging Measurement Range | 0.05 ~ 40 meters |
| Ranging Measurement Accuracy | ±3mm |
| Distance Unit | m, ft, in, cm, mm |
| Area Unit | m², ft², in², cm², mm² |
| Volume Unit | m³, ft³, in³, cm³ |
| Laser Type | 630 ~ 670nm |
| Laser Hazard Level | Class 2 (<1mW) |
| Data Storage | 100 groups |
| Working Temperature | 0 ~ 40℃ |
| Storage Temperature | -10 ~ 60℃ |
| Screen | TFT 2.4 Color screen |
| Automatic Shutdown Time | 3 min |
| Battery | Type-C interface 1000mAh built-in lithium battery |
| Frame Material | PC plastic + aluminum alloy |
| Size | 69.9*67.9*25.1mm |
| Weight | 101g |
| Certification | CE, FCC, WEEE, KC, RoHS |

Figure 14: Back of the device with printed specifications and certifications.
7. Maintenance and Safety
7.1. General Maintenance
- Do not use organic solvents to clean this precision equipment.
- Keep it away from water and corrosive substances.
- Do not damage the working surface of the machine.
- Clean any dirt with a soft cloth to maintain its accuracy.
- The device features automatic shutdown after 3 minutes of inactivity to save battery.
7.2. Battery Charging
The G161-LCD is equipped with a 1000mAh built-in lithium battery. Charge it using the provided Type-C cable via the Type-C charging port.

Figure 15: Type-C charging port and battery information.
7.3. Laser Safety
This product uses a Class 2 laser (<1mW). Avoid direct eye exposure to the laser beam. Do not disassemble the laser module.
8. Troubleshooting (Screen Error Codes)
If an error code appears on the screen, refer to the table below for possible causes and solutions:
| Error Code | Cause of Error | Solution |
|---|---|---|
| Err10 | Low charge | Timely charging |
| Err08 | Measurement does not conform to logic, or data is wrong | Measure according to measurement logic |
| Err26 | Data exceeds display range | Switch to a larger unit |
| Err02 | Out of range | Please range the target within the range |
| Err16 | Instrument wobbles, signal error | Reduce body shaking, or change the measurement target |
| Err01 | Weak signal | Use a reflector with high reflectivity or select a high inverse target |
9. User Tips
- For outdoor measurements or in bright conditions, ensure the backlight is adjusted for optimal visibility.
- Utilize the magnetic base for hands-free operation on metal surfaces, especially when precise angle measurements are needed.
- Regularly check the battery level to avoid interruptions during critical tasks. The Type-C charging allows for convenient power-ups.
- When measuring long distances or in challenging environments, consider using the delay measurement function to ensure stability and accuracy.
- Keep the laser emission and receiving windows clean to maintain measurement accuracy.
10. Warranty and Support
10.1. Warranty Information
All products sold are guaranteed for one year. The warranty period starts from the date of purchase. Please adhere to the following warranty regulations:
- During the warranty period, faulty instruments will be judged, and repair or replacement will be provided.
- The warranty card must be provided with the instrument for warranty claims, along with the invoice if necessary.
- For repairs or replacements, please contact your local dealer.
10.2. Warranty Exclusions
No warranty is provided for instruments under the following conditions:
- Disassembly of the instrument without authorization.
- Incorrect operation or manual damage to the instrument.
- Damage caused by not using original accessories.
- Instrument given to an unauthorized person or unit for repair.
- Instrument whose serial number has been deleted.