1. Introduction
The eletechsup R4IVB02 is a low-cost, stable, and reliable 2-channel analog acquisition module designed for industrial applications. It supports the RS485 Modbus RTU protocol and is based on a highly integrated chip featuring a 12-bit ADC, operational amplifier, and voltage reference. This module is suitable for use with PLCs, HMIs, and other systems requiring analog data collection, offering both voltage and current input versions.
2. Safety and Warnings
Please read all instructions carefully before using this device. Failure to follow these instructions may result in product damage or personal injury.
- Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Do not expose the device to water or moisture.
- Handle with care to avoid cuts or injuries, especially when working with wiring.
3. Specifications
| Feature | Description |
|---|---|
| Type | DC/DC Converters |
| Working Voltage | 4-5.5V or 6-25V (two versions) |
| Working Current | 10-13mA |
| Output Current | 0-21mA |
| Output Frequency | <120Hz |
| Output Type | DUAL |
| MODBUS RTU Command | Write 06/16, Read 04/03 |
| Channels | 2 (IN1/IN2) |
| Voltage Measuring Range | 0-11V |
| Current Measuring Range | 0-21mA |
| Accuracy | 0.5% (calibratable if error > 1%) |
| Resolution (Voltage) | 0.01V (12Bit ADC) |
| Resolution (Current) | 0.01mA (12Bit ADC) |
| Terminal Block | 3.96MM (requires 2.0-2.5MM slotted screwdriver) |
| Dimensions | 41.5 x 20 x 6 mm |
| Weight | 6.5 grams |
| Certification | CE |
| Origin | Mainland China |
4. Setup and Installation
4.1. Before First Use
- Remove all protective films from the device.
4.2. Interface Definition
The module features the following terminal connections:
- VIN: Power input +
- GND: Power input -
- A+: RS485 signal A+
- B-: RS485 signal B-
- GND: Signal common -
- IN1: Signal 1+ (Analog Input Channel 1)
- IN2: Signal 2+ (Analog Input Channel 2)
4.3. Wiring Diagrams
Refer to the diagrams below for proper connection of voltage and current sensors, as well as RS485 bus configurations.
The module is available in different versions based on power input and signal input type:
- Power supply 6-25V, 0-5V/10V input
- Power supply 4-5.5V, 0-5V/10V input
- Power supply 6-25V, 0/4-20mA input
- Power supply 4-5.5V, 0/4-20mA input
5. Operation
The R4IVB02 module communicates using the MODBUS RTU protocol over RS485.
5.1. MODBUS RTU Commands
- Write Commands: Function codes 06/16
- Read Commands: Function codes 04/03
These commands can be input via a PLC or a computer serial port using a super terminal. In MODBUS RTU command mode, up to 247 devices can be supported in parallel on the same bus, provided each device is configured with a unique RS485 address.
5.2. Product Demonstration
6. Maintenance
- After use, turn off the device and store it in a dry place.
- Regularly inspect the module for any signs of physical damage or corrosion.
- Keep the device clean and free from dust and debris.
- Avoid exposing the module to extreme temperatures or humidity.
7. Troubleshooting
If you encounter issues with your R4IVB02 module, consider the following:
- No Power: Verify that the power input (VIN and GND) is correctly connected and within the specified voltage range (4-5.5V or 6-25V, depending on version).
- Communication Issues:
- Check RS485 A+ and B- connections for correct polarity.
- Ensure all devices on the RS485 bus have unique addresses.
- Confirm the baud rate and communication parameters match between the module and the master device (PLC/PC).
- Verify the RS485 converter (e.g., USB to RS485) is functioning correctly.
- Inaccurate Readings:
- Ensure the sensor is correctly wired to IN1/IN2 and GND.
- Confirm the module version (voltage or current input) matches the sensor type.
- Check for electrical noise or interference in the environment.
- If the measurement accuracy error is greater than 1%, the module can be calibrated. Refer to advanced documentation or contact support for calibration procedures.
- Module Not Responding: Disconnect power, wait a few seconds, and reconnect. If the issue persists, inspect for physical damage.
8. Applications
The R4IVB02 module is versatile and can be used in various applications, including:
- PLC Output expansion boards
- Smart Home, Home Automation, Wiser Home systems
- PTZ CCTV Camera control
- Security Monitoring systems
- Interfacing with Displacement/Hall sensors
- Interfacing with PT100, K, P, J Thermocouple Sensors
- Automatic curtain control systems
- Reading 0-20mA/4-20mA Current Sensors
- Reading 0-10V/0-5V Voltage Sensors
- Motion detector integration
- General industrial field measurement and sensing
9. Warranty and Support
For technical support, warranty inquiries, or further information, please contact the manufacturer or their authorized representative.
Manufacturer Information:
- Company: Guangzhou Keshen Electronic Technology Co., Ltd
- Address: CN-Room 301, No.8-1 Beixin Street, Kemulang Aotou, Tianhe District, Guangzhou City
- Email: eletechsup@163.com
EU Authorized Representative:
- Company: TOCYA TRADING
- Address: 79 rue de patay, 75013, Paris
- Email: TOCYATRADING75013@outlook.com
Additional item guides and documents, including a user manual in PDF format, may be available. Please refer to the product listing or contact support for access. The PDF user manual can be found at: User manual (PDF).
10. User Tips
- When connecting multiple modules on an RS485 bus, ensure each module has a unique address to prevent communication conflicts.
- For optimal accuracy, consider using shielded cables for analog signal inputs, especially in noisy industrial environments.
- Always double-check wiring connections before applying power to avoid damage to the module or connected devices.