1. Introduction
The MASTECH MS6818 is a professional, portable advanced cable locator designed for tracing wires, detecting faults, and locating metal pipes. It features dual-mode detection (manual and automatic), adjustable sensitivity, AC/DC voltage testing up to 400V, Non-Contact Voltage (NCV) testing, and a built-in flashlight for convenience in various working environments.

This manual provides detailed instructions for the safe and effective use of your MS6818 device.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure proper insulation when working with live circuits.
- Do not use the device if it appears damaged or is not operating correctly.
- Avoid exposing the device to extreme temperatures, direct sunlight, or high humidity.
- Ensure batteries are correctly installed and replaced when low.
- Do not attempt to repair or modify the device yourself. Refer to qualified service personnel.
- Always wear appropriate personal protective equipment (PPE) when working with electrical systems.
3. Package Contents
Carefully unpack the device and check for any damage. If any items are missing or damaged, contact your supplier immediately.

- Transmitter (MS6818-T) x1
- Receiver (MS6818-R) x1
- Storage Bag x1
- Grounding Stake x1
- Test Line (Red/Black) x1
- Test Clip (Red/Black) x1
- Testing Pen (Red/Black) x1
- Instruction Manual x1
- Color Box x1
4. Setup
4.1 Battery Installation
The MASTECH MS6818 requires batteries for operation (not included).
- Transmitter: Requires one 9V (IEC 6LR61) battery.
- Receiver: Requires six 1.5V AAA (IEC LR03) batteries.
- Locate the battery compartment on the back of both the Transmitter and Receiver.
- Open the battery compartment cover.
- Insert the batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
5. Operating Instructions
5.1 Controls Overview

Receiver (Handheld Unit):
- Probe Head: For sensing signals.
- Flashlight: Illuminates the work area.
- LCD Display Screen: Shows signal strength, mode, voltage, and other information.
- Power On/Off Button: Turns the device on or off.
- Backlight/Mute Composite Key: Controls backlight and mute function.
- Flashlight Button: Activates the flashlight.
- UAC (NCV) Button: Activates Non-Contact Voltage detection.
- Level Up/Down Buttons: Adjust sensitivity.
- MANUAL Button: Switches between automatic and manual detection modes.
- Speaker: Emits audible alerts.
Transmitter (Base Unit):
- Grounding Socket: For connecting the grounding stake.
- Flashlight: Illuminates the work area.
- "+" Socket: For connecting test leads.
- LCD Display Screen: Shows signal level, code, voltage, and transmission status.
- Power On/Off Button: Turns the device on or off.
- Set Button: For various settings.
- Launch/Start Stop Button: Initiates or stops signal transmission.
- Mute Button: Mutes audible alerts.
- Flashlight Button: Activates the flashlight.
- Up/Down Buttons: For navigation and adjustments.
5.2 Power On/Off
Press the Power On/Off button on both the Transmitter and Receiver to turn them on. Press again to turn them off. The device features an auto power-off function to conserve battery life.
5.3 Dual-Mode Detection (Manual/Automatic)

The Receiver offers both Manual and Automatic detection modes. Press the MANUAL button on the Receiver to switch between these modes. Sensitivity can be adjusted in either mode using the Level Up/Down buttons.
5.4 Tracing Wires and Cables
The MS6818 can trace wires and cables in various scenarios:
- Connect the Transmitter: Connect the Transmitter to the circuit or cable you wish to trace using the test leads and clips/pens. Ensure a good connection. For non-energized circuits, a grounding stake may be used.
- Activate Transmitter: Press the 'Launch' or 'Start Stop' button on the Transmitter to begin signal transmission.
- Use the Receiver: Turn on the Receiver and move its probe head along the suspected path of the cable.
- Interpret Readings: The LCD display and audible buzzer on the Receiver will indicate the presence and strength of the signal, helping you pinpoint the cable's location. Adjust sensitivity as needed.
5.4.1 Underground Cables and Pipes

The MS6818 can detect buried underground cables and electrical circuit faults. In single return line mode, it can achieve a detection depth of up to 2.5 meters (approximately 98.4 inches).
5.4.2 Wall Wiring Fault Detection

Detect the route, breaks, and short circuits of lines buried in walls. The Receiver's probe head is designed to pick up signals through wall materials.
5.4.3 Floor Heating and Water Pipes

Search for water pipes, floor heating pipes, and broken wires or short circuits in electric heating lines beneath the floor.
5.4.4 Fuses, Sockets, and Distribution Boxes

The MS6818 can be used to search for fuses, insurance circuits, concealed sockets, and distribution boxes.
5.5 Fault Detection
The device is capable of detecting short circuits and breakpoints in electrical lines.
5.6 AC/DC Voltage Test (12V~400V)

The Transmitter can measure AC/DC voltage from 12V to 400V. Connect the test leads to the appropriate points in the circuit, and the voltage reading will be displayed on the Transmitter's LCD screen.
5.7 NCV (Non-Contact Voltage) Test

Press the UAC (NCV) button on the Receiver to activate the non-contact voltage sensing function. This allows for safer high-voltage electrical testing without direct contact.
5.8 Silent Mode

In situations where audible alerts might be disruptive (e.g., hospitals), activate the silent mode using the Mute button on either unit. Signal strength can still be determined visually via the simulation bars on the LCD.
5.9 Flashlight
Both the Transmitter and Receiver are equipped with flashlights to illuminate dark work areas. Press the dedicated Flashlight button on each unit to activate it.
6. Maintenance
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the LCD to ensure accurate readings and prevent damage from battery leakage.
- Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
- No Signal Detected:
- Ensure both Transmitter and Receiver are powered on.
- Check battery levels in both units.
- Verify that the Transmitter is properly connected to the circuit/cable.
- Adjust the Receiver's sensitivity.
- Inaccurate Detection:
- Environmental interference (e.g., strong electromagnetic fields) can affect accuracy. Try to minimize such interference.
- Ensure proper grounding if applicable.
- Adjust sensitivity.
- LCD Display Not Working/Indicator Light Not Illuminated:
- Check battery status and replace if necessary.
- Ensure the device is powered on.
8. Specifications
8.1 Transmitter Technical Parameters

| Parameter | Value |
|---|---|
| Output Signal | 125KHz |
| Voltage Test | DC 12 - 400 V ± 2.5%; AC 12 - 400V (50 - 60Hz) ± 2.5% |
| Display Screen | LCD, with function display and bar graph |
| Maximum Voltage Test | Maximum 400 V AC/DC |
| Overvoltage Category | CAT III 300 V |
| Pollution Level | 2 |
| Power Supply | 1x9V, IEC 6LR61 |
| Minimum Current | Approximately 31 mA |
| Maximum Current | Approximately 115 mA |
| Fuse | F 0.5 A 500 V, 6.3x32 mm |
| Work Temperature Range | 0°C to 40°C, maximum 80% relative humidity (non-condensing) |
| Storage Temperature Range | -20°C to 60°C, maximum 80% relative humidity (non-condensing) |
| Altitude | Maximum 2000 m |
| Size | 190 mm x 89 mm x 42.5 mm |
| Weight (Without Battery) | Approximately 360 g |
| Weight (With Batteries) | Approximately 420 g |
8.2 Receiver Technical Parameters

| Parameter | Value |
|---|---|
| Tracking Depth (Monopolar Application) | Approximately 0 to 2 m |
| Tracking Depth (Bipolar Application) | Approximately 0 to 0.5 m |
| Tracking Depth (Single Return Line) | Up to 2.5 m |
| Power Grid Voltage Identification | Approximately 0 to 0.4 m |
| Display Screen | LCD, with function display and bar graph |
| Power Supply | 6x1.5 V AAA, IEC LR03 |
| Minimum Current | Approximately 32 mA |
| Maximum Current | Approximately 89 mA |
| Work Temperature Range | 0°C to 40°C, maximum 80% relative humidity (non-condensing) |
| Storage Temperature Range | -20°C to 60°C, maximum 80% relative humidity (non-condensing) |
| Altitude | Maximum 2000 m |
| Size | 241.5 mm x 78 mm x 38.5 mm |
| Weight (Without Battery) | Approximately 280 g |
| Weight (With Batteries) | Approximately 350 g |
8.3 Overall Dimensions

9. User Tips
- For best results when tracing, ensure the Transmitter is connected securely and the Receiver's probe is moved slowly and steadily along the suspected path.
- When working in noisy environments, utilize the visual signal strength indicator on the LCD in conjunction with or instead of the audible buzzer.
- Always test the device on a known circuit first to familiarize yourself with its operation and signal interpretation.
- When tracing live wires, always prioritize safety and use the NCV function for initial detection before making direct contact.