TNCE WTDZW-63A

Contents

TNCE Din Rail Adjustable Over Voltage Under Voltage Protection Device

Model: WTDZW-63A

Brand: TNCE

1. Product Overview

This product is a Smart Wi-Fi Recloser Switch (Auto-Reclosing Circuit Breaker), model WTDZW-63A. It integrates intelligent control with circuit protection. Beyond standard overload and short-circuit protection, it features a smart module for remote control and status monitoring via a mobile app. Its key feature is the ability to automatically attempt to restore power according to preset strategies after tripping due to transient faults (e.g., lightning surge, temporary overload), enhancing power management intelligence and continuity.

The device provides adjustable overvoltage, undervoltage, and overcurrent protection, along with an automatic reset function. It features a digital display for real-time voltage and current readings.

TNCE Adjustable Voltage Current Protector with digital display showing 220V and 40.0A, indicating Overvoltage, Undervoltage, Overcurrent Protection, and Automatic Reset.
Figure 1: TNCE Adjustable Voltage Current Protector with key features.

2. Important Safety Warnings

▲ WARNING

This product involves high voltage. Improper use may cause electric shock, fire, equipment damage, serious injury, or death.

Professional Installation & Operation:

  • Installation, wiring, and commissioning MUST be performed ONLY by a qualified electrician in compliance with all local electrical codes and regulations.
  • End-users are STRICTLY PROHIBITED from opening the distribution board or performing any physical operations. User operation should be limited to remote monitoring and control via the mobile APP.

Electrical Safety:

  • DO NOT OVERLOAD! The total current of connected loads must NOT exceed the 63A rating.
  • After a trip, the root cause (e.g., short circuit, overload) MUST be identified and completely eliminated by an electrician before any reset attempt. NEVER attempt to close the switch repeatedly without knowing the fault cause.
  • The auto-reclosing function is designed for transient faults only. For permanent line faults, the switch will lock out and alarm after consecutive failed reclosing attempts, and MUST be inspected on-site by an electrician.

Usage Environment:

  • For INDOOR installation in a standard distribution board/cabinet only.
  • The environment must be dry, well-ventilated, and free of corrosive gases or flammable materials.

3. Package Contents

  • WTDZW-63A Smart Recloser Switch Host × 1
  • User Manual (this booklet) × 1

Note: Please check against the actual packaging. Accessories (e.g., DIN rail clips, screws) may be included.

4. Setup

4.1. Installation Guide (For Qualified Electrician Only)

WARNING: The upstream main power MUST be switched OFF and verified de-energized before any work!

  1. Power Off: Disconnect the main switch of the distribution board, hang a warning sign, and verify the installation point is de-energized.
  2. Mounting: Mount the switch vertically onto the 35mm DIN rail inside the distribution board and lock it securely.
  3. Wiring: The electrician must correctly connect the power input and load output wires strictly according to the terminal markings and local regulations.
  4. Inspection: After wiring, the electrician must double-check all connections for correctness and tightness, clear any debris, before restoring power.
Wiring diagram for the TNCE protector, showing input (L, N) and output (L, N) connections with upstream and downstream circuit breakers.
Figure 2: Product Wiring Method (Upper Line In, Lower Line Out).

4.2. Network Configuration & APP Connection

(This step should be performed by the user after power-on, with safety ensured by an electrician.)

Step Instructions Device Indicator Status
1. Preparation
  1. Connect your phone to a 2.4GHz Wi-Fi network.
  2. Download, install, and log into the "Tuya Smart" APP.
Steady on after power-up.
2. Enter Pairing Mode Press and hold the Pairing Button on the device for about 5 seconds (refer to product label). Rapid Blinking.
3. Add Device in APP
  1. Tap "+" or "Add Device" on the APP homepage.
  2. Select category: "Electrical" -> "Circuit Breaker".
  3. Choose "Wi-Fi" as the connection method.
APP starts searching.
4. Configure Network Follow APP prompts, select your 2.4G Wi-Fi network and enter the password. Slow Blinking (Connecting).
5. Completion Wait for the APP "Add Success" prompt. Steady On (Device Online).

5. Operating the Device

5.1. Product Interface Overview

Diagram showing the front panel of the TNCE protector with labels for Incoming Line (N, L), Overvoltage Indicator, Undervoltage Indicator, Overcurrent Indicator, Power Indicator, Setup Button, Operating Voltage, Operating Current, Confirm Button, and Outlet Terminal (N, L).
Figure 3: Product Interface Overview.
  • Incoming Line (IN): Terminals for connecting the power input (Neutral and Live).
  • Outlet Terminal (OUT): Terminals for connecting the load output (Neutral and Live).
  • Digital Display: Shows real-time operating voltage and current.
  • Indicators: Separate indicators for Overvoltage, Undervoltage, Overcurrent, and Power status.
  • SET Button: Used to enter settings mode.
  • Up/Down Buttons: Used to adjust parameter values.
  • Confirm Button: Used to confirm settings.

5.2. Core APP Functions (Tuya Smart APP)

  • Status Monitoring: Remotely view the real-time switch status (ON, OFF, Tripped, Fault).
  • Remote Control: Remotely execute CLOSE (power on) and OPEN (power off/trip) commands via the APP.
  • Recloser Management: (If supported) Enable/disable auto-reclosing and set attempt counts & delay intervals within the APP.
  • Smart Alarms: Real-time alerts are pushed to the APP for events like tripping or reclosing failure.
  • Energy Statistics: (If supported) View circuit data like voltage, current, power, and energy consumption.

5.3. Multiple Setting Functions (Device Interface)

The device offers 19 configuration methods for various protection parameters. To access settings, press the 'SET' button. Use the Up/Down buttons to navigate and adjust values, and the Confirm button to save.

Detailed diagram of setting parameters P-1 to P-12 on the TNCE protector's display. Includes Power-on delay (1s-999s), Recovery Delay (1s-999s), Overvoltage Setting (130V-300V), Overvoltage recovery (125V-295V), Undervoltage Setting (80V-210V), Undervoltage recovery (85V-215V), Overvoltage Action Delay (0.1s-10s), Voltage correction (-10% - +10%V), Overcurrent Setting (1-40A/63A), Overcurrent Action Delay (0.1s-10s), Overcurrent Count (0-20 times), Current correction (-10% - +10%V).
Figure 4: Detailed Setting Parameters P-1 to P-12.
Detailed diagram of setting parameters P-13 to P-19 on the TNCE protector's display. Includes Frequency correction (-2.5% - +2.5%Hz), Rapid Power Down Protection (on/off), Display Mode (Standard, Manual, Auto Switch), Automatic Reset (on/off), Action/Gate Mode (on/off), Energy-saving mode (on/off), Set lock password (000-999).
Figure 5: Detailed Setting Parameters P-13 to P-19.

Important Notes on Settings:

  • When the overvoltage setting is lower than the undervoltage setting, the protector will remain in the protective state.
  • To reset all parameters to factory defaults, press and hold the power button for over 5 seconds while the device is powered off.

6. Maintenance

The TNCE WTDZW-63A is designed for reliable operation with minimal maintenance. Regular checks can help ensure its longevity and proper function:

  • Visual Inspection: Periodically inspect the device and its wiring for any signs of damage, loose connections, or overheating.
  • Environment: Ensure the installation environment remains dry, well-ventilated, and free from corrosive gases or flammable materials.
  • Cleaning: If necessary, gently clean the exterior of the device with a dry, soft cloth. Do not use liquids or abrasive cleaners.
  • Firmware Updates: Check the Tuya Smart APP periodically for any available firmware updates for the device to ensure optimal performance and security.

7. Troubleshooting

Symptom Possible Cause Solution (For Electrician)
APP Cannot Add Device
  • Phone not on 2.4G Wi-Fi.
  • Not in pairing mode.
  • Weak signal.
  • Switch phone network.
  • Re-enter pairing mode (rapid blink).
  • Check signal or reposition device.
APP Shows "Offline"
  • Device lost power.
  • Router/network issue.
  • Wi-Fi password changed.
  • Check power supply.
  • Check home network.
  • Re-configure Wi-Fi in APP.
Auto-Reclosing Unsuccessful
  • Permanent fault on the line.
  • Function disabled.
  • Device fault.
DO NOT force reset! Electrician MUST locate and repair the line fault. Check APP settings.
Remote Control No Response
  • Device offline.
  • Control module fault.
  • Check online status, try re-pairing.
  • Contact technical support.

8. Specifications

Attribute Value
Model WTDZW-63A
Rated Current 63A (Also available in 40A variant)
Rated Operational Voltage AC 230V (Voltage Range Display: 80-300V)
Wireless Connection Wi-Fi 2.4G
Operating Temperature -5°C ~ +40°C
Mounting 35mm DIN Rail Mount
Control Platform Tuya Smart APP
EU LVD Voltage High voltage: Above 50Vac or 75Vdc
Certification CE, RoHS
Dimensions (Approx.) 37.0mm (width) x 90mm (height) x 65.5mm (depth)
Diagram showing the dimensions of the TNCE protector: 37.0mm (1.46in) width, 90mm (3.54in) height, 65.5mm (2.58in) depth, with internal component measurements of 46mm (1.81in) and 36.5mm (1.44in).
Figure 6: Product Parameters and Dimensions.

9. User Tips

To maximize the benefits and ensure safe operation of your TNCE WTDZW-63A protector, consider the following tips:

  • Professional Installation: Always ensure installation is carried out by a qualified electrician to prevent hazards and ensure compliance with local codes.
  • App Familiarization: Spend some time exploring the Tuya Smart APP features. Understanding remote control, status monitoring, and alarm functions will enhance your experience.
  • Parameter Customization: Adjust the overvoltage, undervoltage, and overcurrent settings to match the specific requirements and sensitivities of your connected appliances and electrical system.
  • Regular Monitoring: Utilize the APP's status monitoring and energy statistics features to keep an eye on your electrical system's health and identify potential issues early.
  • Safety First: In case of a trip, always investigate the cause thoroughly before attempting to reset the device, especially if the auto-reclosing function is enabled.

10. Compliance

This product is designed to comply with the following harmonized standards and technical specifications:

Standard Type Standard Number & Date
Electrical Safety EN IEC 62368-1:2020+A11:2020
Human Exposure (EMF) EN IEC 62311:2020
EMC & Radio
  • ETSI EN 301 489-1 V2.2.3
  • ETSI EN 301 489-17 V3.2.4
  • ETSI EN 300 328 V2.2.2
Substance Restrictions
  • IEC 62321-1:2013, IEC 62321-2:2021,
  • IEC 62321-3-1:2013, IEC 62321-5:2013,
  • IEC 62321-4:2013+AMD1:2017 CSV,
  • IEC 62321-6:2015, IEC 62321-7-1:2015,
  • IEC 62321-7-2:2017, IEC 62321-8:2017
Electricity Metering Equipment EN 50470-1:2006+A1:2018

For a detailed user manual in PDF format, please refer to the official document: User manual (PDF)

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.