1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of the Aninerel 4200W 24V Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
This unit is a hybrid solar inverter/charger designed for 4.2KVA/5.0KVA 230Vac systems. It features dual output for smart load management, lithium battery activation, a colored LCD with RGB lights, and is compatible with LiFePO4 batteries via RS485. It includes a built-in MPPT 120A solar charger, supports up to 500Vdc PV input, and is capable of working without a battery. WiFi remote monitoring is also supported.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
- Fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview
The Aninerel Hybrid Solar Inverter features a comprehensive design with clearly labeled components for easy installation and operation. Below is an overview of the unit's physical features and connections.
- LCD display: Shows operating status and input/output power information.
- Function buttons: Used for navigation and setting adjustments.
- RGB Indicator: Provides visual feedback on the inverter's status.
- Power on/off switch: Controls the main power to the unit.
- Battery input: Connection point for battery bank.
- AC input: Connection for utility grid or generator AC power.
- Main output: Primary AC output for loads.
- Second output: Secondary AC output for loads.
- WiFi antenna port: For connecting the WiFi module for remote monitoring.
- RS485 communication port: For communication with external devices, such as LiFePO4 batteries.
- Grounding: Essential safety connection.
- PV input: Connection for solar PV modules.
4. Setup and Installation
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1 (PDF version available: User manual (PDF))
- PV connector x 2
- WiFi antenna x 1
4.2 Preparation
Before connecting all wirings, please remove the bottom cover by removing three or two screws as shown in the product overview diagram.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces clear as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. It's recommended to use M4 or M5 screws.
4.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. Please refer to the table below for typical amperage as required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.
| Model | Maximum Amperage | Battery Capacity | Wire Size | Cable mm² | Terminal Size (mm) L | Terminal Size (mm) W | Terminal Size (mm) D | Torque Value |
|---|---|---|---|---|---|---|---|---|
| 4.2KVA | 175A | 200AH | 1AWG | 50 | 37 | 15.3 | 6.4 | 4~6 Nm |
| 5.0KVA | 105A | 200AH | 2AWG | 35 | 37 | 15.3 | 6.4 | 4~6 Nm |
Follow these steps to implement battery connection:
- Make positive and negative cables based on recommended terminal size.
- Connect all battery packs as units require. It's suggested to use recommended battery capacity.
- Insert battery cable flatly into the battery connector of the inverter and make sure the bolts are tightened with a torque of 4~6Nm. Ensure polarity at both the battery and the inverter/charger is correctly connected and battery cables are tightly screwed to the battery connector.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal. Otherwise, overheating may occur.
CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
4.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between the inverter and the AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 50A.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Torque Value |
|---|---|---|
| 4.2KVA | 10AWG | 1.4~1.6Nm |
| 5.0KVA | 10AWG | 1.4~1.6Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open the DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- Make sure the wires are securely connected.
CAUTION: Important. Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are operated in parallel.
CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation. Otherwise, the inverter/charger may trigger an overload fault and cut off output, but internal damage to the air conditioner may still occur.
4.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Typical Amperage | Cable Size | Torque |
|---|---|---|---|
| 4.2KVA | 27A | 10 AWG | 1.4~1.6 Nm |
| 5.0KVA | 27A | 10 AWG | 1.4~1.6 Nm |
When selecting proper PV modules, please be sure to consider these parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
PV Module Wire Connection:
Follow these steps to implement PV module connection:
- Remove insulation sleeve 6 mm for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Make sure the wires are securely connected.
4.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws as shown in the product overview diagram.
5. Operation
5.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the side of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel, located on the front of the inverter, includes a LCD display, three indicators, and four function keys. These provide operating status and input/output power information.
RGB Indicator Messages:
| Mode | RGB Indicator | Messages |
|---|---|---|
| Inverter mode | Green Solid On | Output is powered by battery or PV; Battery is fully charged or isn't charged. |
| Green Flashing | Battery is charging with 2s-on and 1s-off. | |
| AC mode | Blue Solid On | Output is powered by AC or PV in AC mode; Battery is fully charged or isn't charged. |
| Blue Flashing | Battery is charging with 2s-on and 1s-off. | |
| Standby mode | Cyan Solid On | Battery is fully charged or isn't charged. |
| Cyan Flashing | Battery is charging with 2s-on and 1s-off. | |
| Fault mode | Red Solid On | Fault occurs in the inverter. |
| Bypass mode | Purple Solid On | Working in AC mode without charging. |
| Charging mode | Yellow Solid On | Battery is fully charged, when switch is off. |
| Yellow Flashing | Battery is charging, when switch is off. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode. |
| UP | To go to previous selection. |
| DOWN | To go to next selection. |
| ENTER | To confirm the selection in setting mode or enter setting mode. |
5.3 LCD Display Description
The LCD display information can be switched by pressing the function keys. All information is shown across five areas of the LCD:
- Area 1: Shows PV data (voltage/current/power).
- Area 2: Shows battery data (voltage/current/power/SOC).
- Area 3: Shows AC-output data (voltage/current/power/percentage/frequency).
- Area 4: Shows AC-input data (voltage/current/power/percentage/frequency).
- Area 5: Shows setting program code/Eco/buzzer/error/warning.
LCD Data Polling Display Mode:
Simultaneously polling data: Press "UP" or "DOWN" button to show all data from area-1 to area-4 simultaneously. All data will be updated with pressing. Press the ESC key to return to the initial data.
Independent polling data: Data of areas 1-4 can be polled independently:
- Press "Enter" key, the circle icon of area 1 will flash. Press "UP" or "DOWN" to display data of area 1.
- Continue to press "Enter" key, the circle icon of area 2 will flash. Press "UP" or "DOWN" to display data of area 2.
- Continue to press "Enter" key, the circle icon of area 3 will flash. Press "UP" or "DOWN" to display data of area 3.
- Continue to press "Enter" key, the circle icon of area 4 will flash. Press "UP" or "DOWN" to display data of area 4.
- Continue to press "Enter" key, the circle icon of area 1 will flash, returning to area 1.
5.4 LCD Setting
After pressing and holding the "Enter" key for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" to select setting programs. Then, press "ENTER" to confirm the selection or "ESC" to exit. In setting mode, the LCD display shows:
- Area 5: Setting program code.
- Area 1: Setting minimum value (if applicable).
- Area 4: Setting maximum value (if applicable).
- Area 2: Setting program item.
- Area 3: Current value which can be set.
A detailed list of setting programs and their selectable options is available in the full PDF manual. Key settings include Output source priority (UTL, SOL, SBU, SUB, SUF), Maximum charging current, AC input voltage range, Battery type (AGM, Flooded, User-Defined, LI2, LI4, LIB), Auto restart options, Output voltage/frequency, Auto bypass, Maximum utility charging current, and various voltage points for battery and utility source switching.
5.5 Wi-Fi Plug Pro Quick Installation Guideline
The inverter supports Wi-Fi remote monitoring via a dedicated app. Follow these steps to set up the Wi-Fi module:
- Install the wireless antenna: Refer to the schematic diagram for proper installation.
- Download the APP: Scan the QR code provided in the manual or search for "SmartESS" in your app store (iPhone App Store; Android phone).
- Register: Open the APP, click "Registration", and select "Mobile phone Registration" or "Email Registration".
- Enable Bluetooth/WiFi: Turn on Bluetooth or WiFi on your smartphone as needed.
- Connect to the digital collector: Click "Toolbox" in the app and select "BLE network" or "Wi-Fi network". If choosing Bluetooth, the app will scan for nearby devices. Find the PN corresponding to your digital collector and click "Connect".
- Add Datalogger: Log in to your account, click the Datalogger button, tap the "+" button on the top-right, and follow prompts to enter information. The PN number is next to the machine appliance label (Initial Password: 12345678).
- Networking Settings: Select the corresponding 2.4G WiFi, fill in the password, and click "Start Connecting to the Network".
6. Maintenance
6.1 Battery Equalization
The equalization function is integrated into the charge controller to reverse the buildup of negative chemical effects like stratification and remove sulfate crystals from battery plates. This helps maintain overall battery capacity and extends lifecycle. It is recommended to equalize batteries periodically.
How to Apply Equalization Function:
You must enable the battery equalization function in monitoring LCD setting program 33 first. Then, you may apply this function by either of the following methods:
- Setting equalization interval in program 37.
- Active equalization immediately in program 39.
When to Equalize:
In the float stage, when the setting equalization interval (battery equalization cycle) is reached, or equalization is activated immediately, the controller will start to enter the Equalize stage.
Equalize Charging Time and Timeout:
In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage raises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is reached.
However, if the battery equalized time expires and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
6.2 Setting for Lithium Battery
If using a lithium battery with the inverter, ensure it is a compatible model. There are two connectors on the lithium battery: the RS485 port of the BMS and the power cable.
Lithium Battery Connection:
- Assemble battery terminals based on recommended battery cable and terminal size (same as Lead acid, see section Battery Connection for details).
- Connect the end of the RS485 port of the battery to the BMS (RS485) communication port of the inverter.
Lithium Battery Communication and Setting:
If choosing a lithium battery, make sure to connect the BMS communication cable between the battery and the inverter. This cable delivers information and signals between the lithium battery and the inverter, allowing for:
- Re-configuring charging voltage, charging current, and battery discharge cut-off voltage according to the lithium battery parameters.
- The inverter to start or stop charging according to the status of the lithium battery.
Make sure the lithium battery RS485 port connects to the inverter is Pin to Pin. The communication cable is typically included in the package. The inverter RS485 port pin assignment is as follows:
| Pin Number | RS485 Port |
|---|---|
| PIN1 | RS485-B |
| PIN2 | RS485-A |
| PIN7 | RS485-A |
| PIN8 | RS485-B |
LCD Setting for Lithium Battery:
After connecting, you need to finish and confirm some settings:
- Select program 05 as lithium battery type.
If communication between the inverter and battery is successful, information from the BMS will be shown on the LCD:
- Communication successful icon: 'Li' will be flashing.
- Max lithium battery charging voltage.
- Max lithium battery charging current.
- Lithium battery discharging is forbidden: 'Li' will flash once every 1 second.
- Lithium battery charging is forbidden: 'Li' will flash once every 2 seconds.
- Lithium battery SOC (%).
Setting for Lithium Battery Without Communication:
This suggestion is for lithium battery applications without communication to avoid BMS protection. Follow these settings:
Recommended method 1: Set battery type as "LIB" in program 05.
Recommended method 2: Setting as follows:
- Before starting setting, obtain the battery BMS specification (Max charging voltage, Max charging current, Discharging protection voltage).
- Set battery type as "LIB" in program 05.
- Set C.V voltage as Max charging voltage of BMS-0.5V in program 26.
- Set floating charging voltage as C.V voltage in program 27.
- Set Low DC cut-off voltage (discharging protection voltage) in program 29.
- Set Max charging current in program 02, which must be less than the Max charging current of BMS.
- Set voltage point back to utility source when selecting "SBU priority" in program 12.
The setting value must be ≥ Low DC cut-off voltage + 2V, or else the inverter will show a warning for low battery voltage.
Remark:
- It is recommended to finish setting without turning on the inverter (just let the LCD show, no output).
- When you finish setting, please restart the inverter.
7. Troubleshooting
This section provides guidance for common issues and their solutions. If problems persist, contact qualified service personnel.
7.1 Fault Reference Code
| Fault Code | Fault Event |
|---|---|
| 01 | Over temperature of inverter module |
| 02 | Over temperature of DCDC module |
| 03 | Battery voltage is too high |
| 04 | Over temperature of PV module |
| 05 | Output short circuited. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 10 | PV over current |
| 11 | PV over voltage |
| 12 | DCDC over current |
| 13 | Over current or surge |
| 14 | Bus voltage is too low |
| 15 | Inverter failed (Self-checking) |
| 18 | Op current offset is too high |
| 19 | Inverter current offset is too high |
| 20 | DC/DC current offset is too high |
| 21 | PV current offset is too high |
| 22 | Output voltage is too low |
| 23 | Inverter negative power |
| 24 | Op2 current offset is too high |
7.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 02 | Temperature is too High | Beep three times every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 14 | Fan blocked | None |
| 15 | PV energy is low | Beep twice every 3 seconds |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second |
| 21 | Lithium Battery over current | None |
| 22 | The load exceeds the set value of program 47 | None |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
7.3 General Troubleshooting Steps
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts Down automatically during startup process. | LCD/LEDs and buzzer active for 3 seconds then off. | The battery voltage is too low. | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. Battery voltage is far too low. 2. Battery polarity is connected reversed. |
1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Input voltage displayed as 0 on LCD, green LED flashing. | Input protector is tripped. | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power (Shore or Generator). | Check if AC wires are too thin and/or too long. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS / Appliance). |
| Green LED is flashing. | Set "Solar First" as priority of output source. | Change output source priority to Utility first. | |
| When unit is turned on, internal relay switches on and off repeatedly. | LCD display and LEDs are flashing. | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. Inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. | Return to repair center. |
| The battery voltage is too high. | Check if spec and quantity of batteries meet requirements. | ||
| Fault code 06/22 | Output abnormal (Inverter voltage below 190Vac or higher than 260Vac). | 1. Reduce the connected load. 2. Return to repair center. |
|
| Fault code 08/09/15 | Internal components failed. | Return to repair center. | |
| Fault code 13 | Over current or surge. | Restart the unit. If error happens again, return to repair center. | |
| Fault code 14 | Bus voltage is too low. | If wires are connected well, return to repair center. | |
| Another fault code | If the wires are connected well, please return to repair center. |
8. Specifications
8.1 Table 1 Line Mode Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
8.2 Table 2 Inverter Mode Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Rated Output Power | 4.2KVA / 4.2KW | 5.0KVA / 5.0KW |
| Dual output function | Yes | Yes |
| Max. main output power | 4.2KVA | 5.0KVA |
| Max. second output power | 4.2KW | 5.0KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz or 60Hz | |
| Peak Efficiency | 94% | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| Low DC Warning Voltage (Just for AGM and Flooded @ load < 20%) | 22.0Vdc | 44.0Vdc |
| Low DC Warning Voltage (Just for AGM and Flooded @ 20% ≤ load < 50%) | 21.4Vdc | 42.8Vdc |
| Low DC Warning Voltage (Just for AGM and Flooded @ load ≥ 50%) | 20.2Vdc | 40.4Vdc |
| Low DC Warning Return Voltage (Just for AGM and Flooded @ load < 20%) | 23.0Vdc | 46.0Vdc |
| Low DC Warning Return Voltage (Just for AGM and Flooded @ 20% ≤ load < 50%) | 22.4Vdc | 44.8Vdc |
| Low DC Warning Return Voltage (Just for AGM and Flooded @ load ≥ 50%) | 21.2Vdc | 42.4Vdc |
| Low DC Cut-off Voltage (Just for AGM and Flooded @ load < 20%) | 21.0Vdc | 42.0Vdc |
| Low DC Cut-off Voltage (Just for AGM and Flooded @ 20% ≤ load < 50%) | 20.4Vdc | 40.8Vdc |
| Low DC Cut-off Voltage (Just for AGM and Flooded @ load ≥ 50%) | 19.2Vdc | 38.4Vdc |
8.3 Table 3 Charge Mode Specifications
| Utility Charging Mode | 4.2KVA | 5.0KVA |
|---|---|---|
| Max Charging Current (PV+AC) (@ VI/P=230Vac) | 100Amp | 100Amp |
| Max Charging Current (AC) (@ VI/P=230Vac) | 80Amp | 60Amp |
| Bulk Charging Voltage (Flooded Battery) | 29.2Vdc | 58.4Vdc |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2Vdc | 56.4Vdc |
| Floating Charging Voltage | 27Vdc | 54Vdc |
| Overcharge Protection | 32Vdc | 63Vdc |
| Battery reverse connection protection | No | No |
| Charging Algorithm | 3-Step | |
8.4 Table 4 General Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Operating Temperature Range | -10°C to 55°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 368x312x105 | |
| Net Weight, kg | 6.7 | 9.3 |
9. User Tips
- Always ensure proper ventilation around the inverter to prevent overheating, especially during high load operation.
- Regularly check battery connections for tightness and corrosion to maintain optimal performance and safety.
- Utilize the Wi-Fi monitoring feature to keep track of your system's performance and battery status remotely.
- For optimal battery health, consider implementing the battery equalization function periodically, especially for lead-acid batteries.
- When configuring settings, double-check all parameters, particularly for battery type and voltage cut-offs, to match your specific battery bank.
10. Warranty and Support
For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your authorized Aninerel dealer. Keep your purchase receipt as proof of purchase.
If you encounter any issues not covered in the troubleshooting section or require technical assistance, please contact Aninerel Official Store customer support or a qualified service center.
For further details, you may also refer to the official user manual PDF: Aninerel Hybrid Solar Inverter User Manual (PDF).