KKMOON TT-E22028

Contents

KKMOON Smoke and Carbon Monoxide Alarm

Model: TT-E22028

Introduction

This device is a combination smoke and carbon monoxide alarm designed to detect both smoke and carbon monoxide (CO) in residential and commercial environments. It features a photoelectric smoke sensor and an electrochemical carbon monoxide sensor for reliable detection. The integrated LCD screen displays carbon monoxide concentration, and an 85 dB voice alert provides clear, loud warnings upon detection of hazards.

Front view of the KKMOON Smoke and Carbon Monoxide Alarm with LCD display
Front view of the KKMOON Smoke and Carbon Monoxide Alarm, showing the LCD display and test buttons.

Safety Information

  • WARNING: To avoid danger of suffocation, keep this plastic bag away from babies and children.
  • This product should not be installed in an environment that is extremely cold, extremely hot, has extremely high wind speed, or often has a lot of smoke and dust. Such conditions can affect the detector's performance and reliability.

Product Features

  • Dual Detection: Combines a photoelectric smoke sensor and an electrochemical carbon monoxide sensor to detect both hazards simultaneously.
  • LCD Display: Features an LCD screen that clearly displays carbon monoxide concentration in parts per million (ppm).
  • Voice Alert: Provides a loud 85 dB voice warning upon detection of smoke or carbon monoxide.
  • Infrared Photoelectric Sensor: Utilizes the principle of infrared light refraction by smoke particles for fire detection. Designed with an optical maze to shield external stray light interference while allowing smoke entry.
  • Robust Design: Unique structural design and photoelectric signal processing technology ensure dust-proof, insect-proof, and anti-interference capabilities, enhancing product stability.
  • Wide Application: Suitable for smoke monitoring in various environments including hotels, office buildings, teaching buildings, banks, libraries, and computer rooms.

Specifications

Attribute Value
ColorWhite
Shell MaterialABS
Installation MethodWall-mounted (or Ceiling)
Detection GasCarbon Monoxide & Smoke
Carbon Monoxide Sensor TypeElectrochemical
Smoke Sensor TypeOptical Maze
Operating Voltage9V Battery (Battery Not Included)
Quiescent Current≤15uA
Alarm Current<75mA
Battery Low Voltage7V ± 0.5V
Operating Temperature0℃~55℃
Relative Humidity≤95%
CO Detection Range0-999ppm
CO Display Error± 30 ppm
Smoke Detection Area20 ㎡
Alarm Volume≥80dB
CO Alarm Value30ppm display, >100ppm alarm
Manual TestingYES
Automatic ResetYES
Sensor Fault DetectionYES
Item Size (L*W*H)11.6*11.6*4.2cm / 4.57*4.57*1.65in
Net Weight187g / 6.6oz
Gross Weight230g / 8.1oz
CertificationCE
Dimensions of the KKMOON Smoke and Carbon Monoxide Alarm
Product dimensions: 11.6cm diameter, 4.2cm height.

Setup and Installation

  1. Unpack: Carefully remove the alarm and all accessories from the packaging. The package includes: 1 * CO & Smoke Alarm (Battery Not Included), 1 * Installation Kit, 1 * Instructions (English).
  2. Battery Installation: Open the battery compartment and insert a new 9V battery (not included), ensuring correct polarity.
  3. Choose Location: Select a central location on a wall or ceiling, away from air vents, windows, doors, and areas prone to high humidity, extreme temperatures, or excessive dust/smoke (e.g., kitchens, bathrooms, garages). Ensure the alarm is within 20 square meters of the area to be monitored.
  4. Mounting: Use the provided installation kit (screws and wall anchors) to securely mount the alarm. Mark the desired drilling spots, drill holes, insert anchors, and then fasten the mounting bracket. Attach the alarm to the bracket.
KKMOON Smoke and Carbon Monoxide Alarm with installation kit
The alarm comes with an installation kit including screws and wall anchors for mounting.

Operating Instructions

  1. Power On: Once the 9V battery is correctly installed, the alarm will power on automatically.
  2. LCD Display: The LCD screen will display the current carbon monoxide concentration in ppm.
  3. Testing: Press the 'TEST' buttons (one for Smoke, one for CO) on the front panel to perform a manual test. The alarm should sound, and the corresponding indicator lights should flash. It is recommended to test the product once a month.
  4. Alarm Conditions:
    • Smoke Alarm: If smoke is detected, the alarm will sound with an 85 dB voice alert.
    • Carbon Monoxide Alarm: If CO concentration reaches or exceeds 100ppm, the alarm will sound with an 85 dB voice alert. The LCD will display the concentration.
    • Alarm Priority: If both smoke and carbon monoxide are sensed simultaneously and both reach their alarm values, the carbon monoxide alarm state takes priority.
  5. Automatic Reset: The alarm features an automatic reset function after an alarm event, provided the detected hazard has cleared.
Close-up of the alarm's front panel with TEST buttons and indicator lights
The front panel features dedicated 'TEST' buttons for Smoke and CO, along with Power, Alarm, and Fault indicator lights.

Maintenance

  • Battery Replacement: The alarm operates on a 9V battery. When the battery voltage drops to 7V ± 0.5V, the device will indicate a low battery warning. Replace the battery immediately with a new 9V battery.
  • Cleaning: To ensure optimal smoke sensitivity, the surface of the detector needs to be cleaned with a soft brush every six months. Always disconnect the power (remove the battery) before cleaning.

Troubleshooting

  • No Alarm During Test: If the alarm does not sound during a manual test, check if the 9V battery is properly installed and has sufficient charge. Replace the battery if necessary.
  • False Alarms: False alarms can occur if the detector is installed in an unsuitable environment (e.g., near cooking fumes, high humidity, or excessive dust). Review the 'Setup and Installation' section for optimal placement.
  • Sensor Fault: The device includes sensor fault detection. If a fault is indicated (e.g., by a specific fault light or sound pattern, refer to the full PDF manual for details), ensure the battery is good and the sensor area is clean. If the fault persists, contact customer support.

User Tips

  • Perform a manual test of your alarm at least once a month to ensure it is functioning correctly.
  • Regularly clean the detector's surface with a soft brush every six months to maintain smoke sensitivity. Remember to remove the battery before cleaning.
  • Be aware that if both smoke and carbon monoxide are detected at alarming levels, the carbon monoxide alarm will take priority.

Manufacturer Information

Manufacturer:

Company Name: shanghai huang shi mao yi Co., Ltd.
Address: Room 3389, Building 2, No.88, Changxu Road, Juyuan New District, Jiading District, Shanghai
Email: b162sumaitn2822@163.com
Telephone: 86-13876659222

EU Authorized Representative:

AR Company Name: SolID AUTHORITY LIMITED
Address: IE-51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Ireland
Email: phoebe8706@gmail.com
Telephone: 33-761441379

Compliance Information

This product is CE certified, indicating compliance with European health, safety, and environmental protection standards.

For a complete and detailed user manual, including additional diagrams and specific fault codes, please refer to the official PDF document: User manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.