SNDWAY SW-DS50

Contents

SNDWAY Laser Distance Meter User Manual

Models: SW-DS50, SW-DS70, SW-DS100, SW-DS120

Brand: SNDWAY

1. Introduction

This manual provides comprehensive instructions for the safe and effective use of your SNDWAY Laser Distance Meter. This digital measuring tool is designed for indoor use, offering various measurement functions with high accuracy.

SNDWAY Laser Rangefinder showing various measurement modes like length, area, Pythagorean, altitude, angle, volume, and wall area.
Figure 1: SNDWAY Laser Distance Meter with various measurement capabilities.

The device features a 2-inch high-definition large screen for easy data observation, even in dark environments, and includes a built-in electronic angle sensor for precise measurements. The series includes models with different measurement ranges, such as 50m, 70m, 100m, and 120m.

Video 1: Demonstration of the SNDWAY Laser Distance Meter's features and measurement functions.

2. Safety Regulations

Please read the safety regulations and operation guide carefully before operating.

  • Improper operations without complying with this manual could cause damage to the device, influence measurement results, or lead to bodily injury.
  • The instrument is not allowed to be disassembled or repaired. Do not make any illegal modifications or performance changes for the laser emitter.
  • Keep the device out of reach of children and avoid use by irrelevant personnel.
  • It is strictly prohibited to aim the laser at eyes or other body parts, or at surfaces with strong reflection.
  • Due to electromagnetic radiation interference, do not use the meter in aircraft or near medical equipment. Avoid use in inflammable or explosive environments.
  • Discarded batteries or the meter device should not be treated as household garbage. Handle them in accordance with relevant laws and regulations.
  • For any quality issues or questions, contact local distributors or the manufacturer for support.

3. Components and Package Contents

3.1. Package Contents

Please check if all accessories are included in the package:

No. Item Unit QTY
1 Laser distance meter pc 1
2 User's manual pc 1
3 Portable bag pc 1
4 Hand strap pc 1
5 Gift box pc 1

Note: Battery 1.5V AAA (x2) are optional and not included in the standard package.

3.2. Device Overview (Display and Keyboard)

Close-up of the SNDWAY Laser Distance Meter's 2-inch high-definition large screen displaying measurement data.
Figure 2: High-definition large screen for clear data display.

The device features a large LCD backlight display and an intuitive keyboard for easy operation.

Display Elements:

  • Power Supply Indicator
  • Record Indicator
  • Length, Area, Volume and Pythagorean Measurement Indicators
  • Laser On Indicator
  • Angle Display
  • Maximum/Minimum Value Display
  • Auxiliary Display Area
  • Major Display Area

Keyboard Functions:

  • READ Button: Turn on/Measure
  • U Button: Unit Switch
  • OFF/CLEAR Button: Turn off/Remove
  • +/- Button: Sound/Addition/Subtraction
  • M Button: Area/Volume/Pythagorean Measurement
  • Reference Point Button: Change Reference Point
  • Record Button: Save/View Records
Diagram showing the dimensions of the SNDWAY Laser Distance Meter: 112mm/4.41 inch length, 50mm/1.98 inch width, 25mm/0.98 inch thickness.
Figure 3: Dimensions of the SNDWAY Laser Distance Meter.

4. Setup

4.1. Battery Installation

  1. Discharge the battery door on the back of device.
  2. Insert two 1.5V AAA alkaline batteries according to the correct polarity.
  3. Cover the battery door.

Important: Only 1.5V AAA alkaline batteries are to be used. If the meter is not used for a long time, remove the batteries to prevent corrosion.

4.2. Turning On/Off the Instrument

  • Turn On: Under off status, press the READ button. The device and laser will start simultaneously and stand by for measurement.
  • Turn Off: Under on status, long press the OFF/CLEAR button for 3 seconds to turn the device off. The device will also shut off automatically if there is no operation for 150 seconds.

4.3. Unit Setting

Long press the U button to reset the current measurement unit. The default unit is: 0.000m. There are 6 units for selection: m, in, ft, 0'00 1/16, 0.00ft, 0.00m.

4.4. Changing Reference Point

Press the Reference Point button to change the reference point. The device reference point by default is rear.

Diagram showing two-stage benchmark options for measurement: Former benchmark and Post-benchmark, with a self-calibration display.
Figure 4: Two-stage benchmark for flexible measurement starting points.

4.5. Backlight On/Off

The backlight is set to turn on and off automatically. It stays on for 15 seconds while operating and will turn off automatically after 15 seconds of no operation.

4.6. Sound On/Off

Long press the +/- button to turn the buzzer sound on or off.

5. Operating Instructions

5.1. Length Measurement

Single Distance Measuring:

  1. Under measuring mode, short press the READ button to turn on the laser beam.
  2. Press the READ button again for a single measurement of length.
  3. The measured result will be displayed in the major display area.
Diagram showing single measurement and continuous measurement modes. For single, a person measures a straight line 'A'. For continuous, the laser continuously emits, showing minimum, maximum, and current values.
Figure 5: Single and Continuous Measurement modes.

Continuous Measuring:

  1. Under measuring mode, long press the READ button to enter continuous measuring mode.
  2. Maximum measuring result displays in auxiliary display area, present result displays in major display area.
  3. Short press the READ button or OFF/CLEAR to exit continuous measuring mode.

5.2. Area Measurement

  1. Press the M button once. The screen will show the area measurement icon with one side of the rectangle blinking.
  2. Press READ once for length.
  3. Press READ again for width.
  4. The device will calculate and display the result in the major display area.
  5. Press OFF/CLEAR to clear the result and measure again if necessary.
  6. Press M again to exit the mode.
Diagram showing area measurement and volume measurement. For area, a person measures length 'A' and width 'B'. For volume, length 'A', width 'B', and height 'C' are measured.
Figure 6: Area and Volume Measurement modes.

5.3. Volume Measurement

  1. Press the M button twice to enter volume measurement mode. The screen will show the volume measurement icon.
  2. Press READ for length.
  3. Press READ again for width.
  4. Press READ a third time for height.
  5. The device will calculate and display the result in the major display area.
  6. Press OFF/CLEAR to clear the result and measure again if necessary.
  7. Press M again to exit the mode.

5.4. Pythagorean Measurement

The device offers four Pythagorean modes for situations where direct measurement is difficult.

Diagram illustrating Pythagorean measurement for calculating vertical distance (C) using hypotenuse (A) and horizontal distance (B).
Figure 7: Pythagorean measurement for indirect height calculation.

Mode 1: Calculate length of two legs (Hypotenuse and Angle)

  1. Short press the M button four times until the hypotenuse icon is blinking.
  2. Press READ to measure the length of the hypotenuse (A). The device will calculate the angle and display the horizontal distance (B) and vertical height (C).

Mode 2: Calculate hypotenuse (Two Legs)

  1. Short press the M button five times until one leg icon is blinking.
  2. Press READ to measure the length of one leg (A).
  3. Press READ again to measure the length of the other leg (B).
  4. The device will calculate and display the length of the hypotenuse (X).

Mode 3: Calculate a leg (Three Measurements)

  1. Short press the M button six times until one side icon is blinking.
  2. Press READ to measure the length of one side (A).
  3. Press READ again to measure the length of the median line (B).
  4. Press READ a third time to measure the length of another side (C).
  5. The device will calculate and display the length of the leg in full line (X).

Mode 4: Calculate a leg (Hypotenuse and Two Legs)

  1. Short press the M button seven times until the hypotenuse icon is blinking.
  2. Press READ to measure the length of one hypotenuse (A).
  3. Press READ again to measure the length of another hypotenuse (B).
  4. Press READ a third time to measure the length of one leg (C).
  5. The device will calculate and display the length of the leg in full line (X).

Note: Legs must be shorter than the hypotenuse, otherwise "Err" will be displayed. Ensure all measurements start from the same point for accuracy.

Diagram showing how to measure angle and heightness with one key. The instrument calculates horizontal distance and vertical height based on the measured straight-line distance and angle.
Figure 8: One-key angle and height measurement.

5.5. Angle Measurement

The angle information is displayed at the top of the screen. The angle measurement range is -90.0° to 90.0°.

SNDWAY Laser Distance Meter tilted at 60 degrees, demonstrating its electronic level and built-in angle sensor.
Figure 9: Electronic level with built-in angle sensor.

5.6. Delay Measurement

  1. Long press the READ button. A second number will show on the screen.
  2. Use the +/- buttons to adjust the delay time.
  3. Press READ to start the countdown. The measurement will begin when the time reaches 0.

5.7. Addition / Subtraction

This function can be used for length, area, and volume calculations.

  1. After obtaining a length measurement result, press the +/- button to select the function.
  2. Short press +/-: "+" appears in the major display area, entering cumulation mode. The value of the last measurement and the cumulative result will be shown.
  3. Press +/- again: "-" appears in the major display area, entering regressive mode. The value of the last measurement and the result of subtraction will be shown.
  4. You can switch between continuous addition and continuous subtraction by pressing the +/- button.

Example for Area Cumulative Function:

  1. Measure the first area (e.g., 0.598).
  2. Press +/-, then measure the second area (e.g., 0.398). A "+" will appear at the bottom left.
  3. Press +/- again to get the summation result (e.g., 0.756).

5.8. Painter Function (Wall Area)

When the meter is in area mode, you can use the add/subtract function to total up the area of several surfaces (e.g., walls).

  1. Press the M button three times until the wall area icon is showing.
  2. Press READ to measure the height of the wall first.
  3. Press READ to measure the bottom edge of the first wall. The first area will be displayed.
  4. Press READ to measure the bottom edge of another wall. The sum of these two walls will be displayed.
  5. Repeat for more walls.
  6. Press OFF/CLEAR to clear the previous measuring result and start a new measurement.
  7. When there is no data in the Auxiliary Display area, press the M button to exit the mode.

5.9. Record Function

Long press the Record button for 3 seconds to record your measuring result under any measuring mode (Length, Area, Volume, Pythagoras). The device can store up to 99 records.

SNDWAY Laser Distance Meter display showing 30 sets of data storage, indicating important data will not be lost.
Figure 10: Data storage capability (up to 99 sets).

Read / Delete Records:

  • Short press the Record button to read the records.
  • Press the +/- button to delete the most recent record.
  • Long press the +/- button to clear all records.
  • Press the READ or OFF/CLEAR button to exit record mode.

6. Self-Calibration

This function allows you to maintain the precision of the device.

  1. Power off the device.
  2. Long press the READ button, then release it.
  3. Press the +/- button, then release it until "CAL" and a figure appear on the screen.
  4. Adjust the figure using the +/- buttons according to the meter's accuracy. The adjustable range is -9 to 9mm.
  5. Long press the READ button to save the calibration result.
Diagram showing the self-calibration feature with a display of 'CAL 9' and adjustable tolerance within ±9mm/0.354 inch.
Figure 11: Self-calibration function for improved accuracy.

7. Troubleshooting (Error Messages)

The device may display error messages to indicate issues. Refer to the table below for common errors and their solutions:

Info Message Cause Solution
Err Out of distance measurement range Use the device within the specified range.
Err1 Signal is too weak Choose a surface with stronger reflectance. Use a reflecting plate if necessary.
Err2 Signal is too strong Choose a surface with weaker reflectance. Use a reflecting plate if necessary.
Err3 Low battery voltage Change the power supply (batteries).
Err4 Working temperature is out of range Use the device within the specified temperature range.
Err5 Pythagorean measuring error Re-measure and ensure that the hypotenuse is larger than the cathetus.
Err6 Angle sensor error Depot Repair (contact support).

8. Specifications

The following table details the technical specifications of the SNDWAY Laser Distance Meter:

Item Specifications
Working Range 0.05-50m/70m/100m/120m (depending on model)
Distance measurement precision ±2mm
Measurement unit options m/in/ft
Continuous measurement function Yes
Outdoor target reflection board No
Area measurement function Yes
Volume measurement function Yes
Pythagorean proposition measurement function Full mode
Add and subtract measurement function Yes
Delay Measurement Yes
Min/Max value Yes
Max storage 99 units
Automatic backlight Yes
Buttons/Keys sound Yes
Laser level II
Laser type 635nm, <1mW
Automatically cut off laser 20s
Automatic shutdown 150s
Storage temperature -20°C to 60°C
Working temperature 0°C to 40°C
Storage humidity 20%-80%RH
Battery 1.5V AAA x2
Battery life 8000 times for single measurement
Angle Range ±90°
Dimension 112x50x25mm

Note: This rangefinder is for indoor use. It cannot be used outdoors. If there is an outdoor range finding requirement, please consult customer service to purchase an indoor and outdoor universal model.

Typical Tolerance: ±2mm, when reflectivity is 100% (white surface) and ambient light is <2000 LUX at 25°C. Tolerance is usually affected by distance, reflectivity, and ambient light. It probably gets tolerance around ± (2mm + 0.2mm/m).

9. Maintenance

  • The meter should not be stored in high temperature and strong humidity environments for long periods.
  • If not used often, remove the batteries and store the meter in the allocated portable bag in a cool and dry place.
  • Keep the device surface clean. Use a wet soft cloth to clean dust. Do not use erosion liquids for maintenance.
  • The laser output window and its focus lens should be maintained according to maintenance procedures for optical devices.

10. User Tips

  • For best accuracy, ensure the device is held steady during measurement.
  • When measuring long distances or in bright conditions, using a reflective target plate can improve accuracy and range.
  • Regularly check battery levels to avoid interruptions during important measurements.
  • Utilize the data storage function to keep track of multiple measurements for later reference.

11. Warranty and Support

For warranty information or technical support, please contact the manufacturer or your local distributor.

Manufacturer Contact:

Dongguan Sndway Electronic Co.,Ltd.
Add: 4th floor, Building A2, Ludipu No. 37, Huaide, Humen
523926, Dongguan, Guangdong, China
Tel: 0769-85265688
Fax: 0769-85116652

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.