1. Introduction
This manual provides detailed instructions for the safe and effective use of your Hti Handheld Thermal Imager. The HT series integrates surface temperature measurement with real-time thermal imaging, offering a professional, precise, and efficient tool for various applications.
Key Features:
- Integrates surface temperature measurement and real-time thermal imaging.
- Central point measurement cursor for quick and accurate temperature measurement of target objects.
- Ideal for electricians, maintenance personnel, and technicians to quickly identify problem areas.
- Applicable in diverse fields including fire fighting, archaeology, traffic, agriculture, geology, energy, smelting, and electronic manufacturing.
Video: Overview of the Handheld Thermal Imager's capabilities and applications.
2. Setup
2.1 Unpacking and Initial Inspection
Carefully unpack your thermal imager and check for any signs of damage. Ensure all components listed in the package contents are present.
2.2 Battery Installation and Charging
For HT-02/HT-02D Models:
These models typically use 4 x AA batteries. It is crucial to use alkaline batteries (1.5V each) as rechargeable (1.2V each) or carbon-zinc batteries may not provide sufficient voltage (4.8V total) for proper operation, leading to "low charge" warnings and device shutdown.
For HT-175 Model:
This model features built-in chargeable 18650 batteries. Connect the device to a power source using the provided USB cable and charger to charge the internal battery.
For HT-18/HT-19 Models:
These models also use built-in chargeable batteries. Use the provided USB cable and charger for recharging.
2.3 Powering On/Off
Locate the On/Off key on the device. Press and hold the key to power the device on or off.
2.4 Language Settings
Upon first use or after a reset, you may need to set the language. Navigate through the menu using the arrow keys and select your preferred language (e.g., English, Chinese, Italian, German).
3. Operating Instructions
3.1 Basic Operation
- Power On: Press and hold the On/Off key.
- Navigation: Use the Up, Down, Left, and Right navigation keys to move through menus and adjust settings.
- Selection: Press the 'SELECT' key to confirm a selection or enter a submenu.
- Menu Access: Press the 'MENU' key to access the main menu.
- Image Capture: Press the 'IMAGE' or 'Image capture key' to take a thermal image.
3.2 Temperature Measurement
The device uses a central point measurement cursor to quickly and accurately measure the temperature of the target object. Point the imager at the area of interest, and the temperature reading will be displayed on the screen.
3.3 Vision Options (for HT-18/HT-19)
The HT-18 model offers full infrared and full vision visible images with 25% steplength blending. The HT-19 model provides 5 kinds of blending from full infrared to full visual, allowing for mixing visible and infrared images to enhance detail and context.
3.4 Palette Selection
Choose from various color palettes to visualize temperature differences. Common palettes include Iron Red, Rainbow, Rainbow High Contrast, Gray Scale (white glow), and Gray Scale (black glow).
3.5 Image Storage
- HT-18: Features built-in 4G storage for captured images.
- HT-19, HT-02/HT-02D: Utilize an SD card (4G included) for image storage. Images are typically saved in JPG or BMP format.
3.6 Auto Power-off
The device can be configured to automatically power off after a period of inactivity (e.g., 5 minutes, 20 minutes, or disabled). Adjust this setting in the device menu to conserve battery life.
4. Product Applications
The Hti Thermal Imager is a versatile tool suitable for a wide range of applications:
- Building Inspection: Detecting floor heating, hot water pipe leaks, and insulation issues.
- Electrical Inspection: Identifying faults in distribution boxes, electrical equipment, and power systems.
- Automotive: Diagnosing automobile faults.
- Industrial Maintenance: Motor fault detection and general equipment inspection.
- Other Fields: Fire fighting, archaeology, traffic management, agriculture, geology, energy audits, smelting processes, and electronic manufacturing.
5. Maintenance
5.1 Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the lens and screen are kept clean for optimal performance.
5.2 Battery Care
- For models using AA batteries (HT-02/HT-02D), remove batteries if the device will not be used for an extended period.
- For models with built-in rechargeable batteries (HT-175, HT-18, HT-19), ensure regular charging to maintain battery health. Avoid fully discharging the battery frequently.
5.3 Storage
Store the thermal imager in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -20°C to 50°C (-4°F to 122°F) and relative humidity of 10%RH to 80%RH.
6. Troubleshooting
6.1 "Low Charge" Warning / Device Turns Off (HT-02/HT-02D)
Problem: The device displays a "low charge" warning and turns off, even after inserting seemingly charged batteries.
Solution: Ensure you are using alkaline AA batteries (1.5V each). Rechargeable AA batteries (1.2V each) or carbon-zinc batteries may not provide the necessary 6V total voltage for the device to operate correctly, leading to this issue. Replace with fresh alkaline batteries.
6.2 Image Quality Issues
Problem: Thermal images appear blurry or unclear.
Solution: Check if the lens is clean. Gently wipe it with a soft, lint-free cloth. Ensure the focus mode (if adjustable on your model) is set correctly, or that you are within the optimal focal distance for fixed-focus models.
6.3 Device Not Responding
Problem: The device is unresponsive to button presses.
Solution: Try performing a soft reset by removing and reinserting the batteries (for AA models) or holding the power button for an extended period (for built-in battery models). If the issue persists, ensure the battery is adequately charged.
7. Specifications
General Specifications (Applicable to most models):
- Display Size: 2.0 - 3.9 Inches (e.g., 3.2'' full-color screen for HT-18/HT-19, 2.0'' color screen for HT-02/HT-02D/HT-175)
- Thermal Sensitivity: 0.07°C (HT-18/HT-19), 0.15°C (HT-02/HT-02D), 0.5℃ (HT-175)
- Temperature Range: -20℃ to 300℃ (-4℉ to 572℉)
- Measuring Accuracy: ±2.5℃ or ±2.5% (HT-18/HT-19), ±2% or ±2℃ (HT-02/HT-02D/HT-175)
- Emissivity: 0.1-1.0 Adjustable
- Focus Mode: Fixed
- Wavelength Range: 8-14μm (HT-18/HT-19), 8-11.5μm (HT-02/HT-02D/HT-175)
- Palette: Iron red, Rainbow, Rainbow High Contrast, Gray Scale (white glow), Gray Scale (black glow)
- Authentication: CE, FCC, RoHS
- Operating Temperature: 0 to 50°C (32°F to 104°F)
- Storage Temperature: -40 to 80°C (HT-18/HT-19), -20 to 50°C (HT-02/HT-02D/HT-175)
- Relative Humidity: <85RH (HT-18), 10%RH to 80%RH (HT-19, HT-02/HT-02D/HT-175)
Model-Specific Specifications:
| Feature | HT-18 | HT-19 | HT-02/HT-02D/HT-175 |
|---|---|---|---|
| Infrared Image Resolution | 220x160 pixels | 320x240 pixels | HT-02: 60x60 pixels HT-02D/HT-175: 32x32 pixels |
| Total Pixel | 35,200 pixels | 76,800 pixels | HT-02: 3600 pixels HT-02D/HT-175: 1024 pixels |
| Visible Image Resolution | 0.3 million pixels | 0.3 mega pixels | |
| Image Frequency | 8Hz | 9Hz | 6Hz |
| Vision Option | Full infrared and full vision Visible image with 25% steplength | 5 kinds of full infrared to full visual, mixing visible and infrared | 5 kinds of full infrared to full visual, mixing visible and infrared |
| Image Storage | Built-in 4G | SD card (4G) | Mini SD card (4G) |
| USB | Micro USB2.0 | N/A (uses USB Charging Cable) | |
| Power Supply | Built-in chargeable 18650 batteries | 4 x AA batteries (HT-02/HT-02D), Built-in chargeable 18650 batteries (HT-175) | |
| Auto Power-off Time | 5 minutes/20 minutes/not power off automatically | 12 Minutes | |
| FOV/Shortest Focal Length | N/A | 27°×35°/0.5m | 20×20/0.5m (HT-02/HT-02D) |
| Dimensions (L*W*H) | 223*105*90mm | 21.2 * 9.5 * 6.2cm (HT-02/HT-02D) 165mm×69mm×60mm (HT-175) |
|
| Weight | 289g | 320g (HT-02/HT-02D) 135g (HT-175) |
|
8. Warranty and Support
8.1 Warranty Information
The HT-02/HT-02D models come with a 2-year warranty period. Please refer to the full user manual for specific warranty terms and conditions for all models.
8.2 Additional Resources
For more detailed instructions, diagrams, and troubleshooting, please refer to the comprehensive user manual available in PDF format:
9. User Tips
- Always use fresh alkaline AA batteries for HT-02/HT-02D models to avoid "low charge" issues.
- Utilize the blending modes (visible and infrared) on HT-19 and HT-02/HT-02D/HT-175 models to get a clearer understanding of the thermal patterns in context with the visible environment.
- Regularly clean the lens and screen to ensure accurate readings and clear images.
- When inspecting electrical systems, remember that the thermal imager helps identify hot spots, which can indicate overloaded circuits, loose connections, or component failures.
- For building inspections, look for sudden temperature changes on surfaces to pinpoint areas of poor insulation, drafts, or moisture.