Aninerel ANL-4.2KW-LV-W

Contents

Aninerel 4200W 24V 120A MPPT Solar Inverter User Manual

Model: ANL-4.2KW-LV-W

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of your Aninerel 120VAC MPPT Solar Inverter. This inverter is designed for off-grid hybrid PV systems, featuring a pure sine wave output, a 120A MPPT solar charger, and a 4200W power output. It supports 120Vac low voltage operation and includes a built-in LCD display and optional WiFi remote monitoring.

Product Features:

  • Low Voltage Input: 24V 120A MPPT design, 4200W high power output, supports 120Vac low voltage operation.
  • Pure Sine Wave Output: Compatible with various household appliances, protecting sensitive electronic devices.
  • LCD Smart Display: Built-in LCD display shows real-time voltage, current, power, and working status.
  • WIFI Remote Monitoring: Optional mobile remote monitoring allows checking inverter status anytime, anywhere.
  • Stability in Unstable Grids: Designed for weak and unstable power grids with multi-level protection for stable, long-term operation.
  • PV Input: Up to 500Vdc Max.
  • Built-in MPPT: 120A.
  • Operation Modes: Capable of working without a battery.
  • Load Management: Single output for smart load management.
  • Environment Adaptability: Detachable dust cover for harsh environments.
  • Battery Compatibility: Compatible with LiFePo4 batteries via RS485.
  • Battery Activation: Lithium battery activation function by PV or Utility.
  • Output Priority: Supports multiple output priorities: UTL, SOL, SBU, SUB.
  • Battery Optimization: EQ function to optimize battery performance and extend lifecycle.
Product features overview with icons
Overview of product features and capabilities.

2. Safety Instructions

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • All wiring must be performed by qualified personnel.
  • Do not attempt to disassemble or repair the unit yourself.
  • Ensure proper grounding of the inverter.
  • Keep the inverter away from flammable materials and moisture.
  • Do not place anything between the flat part of the inverter terminal; overheating may occur.
  • Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
  • Before making final DC connections or closing DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
  • Install a separate DC over-current protector or disconnect device between the battery and inverter.
  • Install a separate AC breaker between the inverter and AC input power source.

3. Setup and Installation

3.1. Unpacking and Inspection

Before installation, inspect the unit for any damage. Ensure all items are present in the package:

  • Inverter Unit x 1
  • User Manual x 1
  • AC terminal (red x 2 / black x 2)
  • PV terminal (red x 1 / black x 1)
  • Ground terminal (black x 1)

3.2. Preparation

Before connecting any wiring, remove the bottom cover by unscrewing the three screws.

3.3. Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level for easy reading of the LCD display.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • Adhere to vertical wall mounting.
  • Ensure sufficient space around the unit for heat dissipation and wiring access (refer to diagram for clearances).

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Product overview with labeled ports and display
Product Overview: Front and rear panel connections and display.

3.4. Battery Connection

It is recommended to install a separate DC over-current protector or disconnect device between the battery and inverter. Use appropriate cable sizes for battery connection to reduce risk of injury.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Do not place anything between the flat part of the inverter terminal. Overheating may occur.

CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.

CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

Recommended Battery Cable & Terminal Size:

Model Maximum Amperage Battery Capacity Wire Size Cable mm² Terminal Size Torque Value
L(mm) W(mm) D(mm)
4.2KVA 175A 200AH 1AWG 50 37 15.3 6.4 4~6 Nm

Steps for Battery Connection:

  1. Prepare battery positive and negative cables according to recommended specifications.
  2. Connect all battery packs as required, using recommended battery capacity.
  3. Insert battery cables flatly into the inverter's battery connector and tighten bolts with a torque of 4~6 Nm. Ensure correct polarity.
Battery connection diagram for 24V system
Diagram for connecting two 12V batteries in series for a 24V system.

3.5. AC Input/Output Connection

CAUTION!! Before connecting to AC input power source, install a separate AC breaker between the inverter and AC input source. This ensures safe disconnection during maintenance and protection from overcurrent. Recommended AC breaker spec is 50A.

CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel.

WARNING! Use appropriate cable for AC input connection to reduce risk of injury.

Suggested Cable Requirement for AC Wires:

Model Gauge Torque Value
4.2KVA 8AWG 1.4~1.6 Nm

Steps for AC Input/Output Connection:

  1. Before making AC input/output connection, open the DC protector or disconnector.
  2. Remove 10mm insulation sleeve for six conductors. Shorten phase L and neutral conductor by 3mm.
  3. Insert AC input wires according to polarities on the terminal block and tighten screws. Connect PE protective conductor (yellow-green) first. L=LINE (brown or black), N=Neutral (blue).
  4. Ensure AC power source is disconnected before hardwiring.
  5. Insert AC output wires according to polarities and tighten screws. Connect PE protective conductor first. L=LINE (brown or black), N=Neutral (blue).
  6. Make sure all wires are securely connected.

CAUTION: Important! Connect AC wires with correct polarity. Reversed L and N wires can cause utility short-circuit in parallel operation.

CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If power fluctuates, it can damage appliances. Check if your air conditioner has a time-delay function. The inverter will trigger an overload fault to protect appliances, but internal damage may still occur.

Close-up of AC IN, AC OUT, and PV IN terminals
Detailed view of AC Input, AC Output, and PV Input terminals.

3.6. PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! All wiring must be performed by qualified personnel.

WARNING! Use appropriate cable for PV module connection to reduce risk of injury.

PV Module Selection Parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.

Solar Charging Mode Specifications:

Parameter Value
INVERTER MODEL 4.2KVA
Max. PV Array Open Circuit Voltage 500VDC
PV Array MPPT Voltage Range 60VDC~500VDC
Max. PV INPUT CURRENT 27A

PV Module Wire Connection Steps:

  1. Remove 6mm insulation sleeve for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
  3. Make sure the wires are securely connected.
PV Connection diagram and table for module selection
PV Connection diagram and table for selecting appropriate PV modules.

3.7. Final Assembly

After connecting all wirings, replace the bottom cover by screwing in the two screws.

4. Operation

4.1. Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the case) to turn on the unit.

4.2. Operation and Display Panel

The front panel of the inverter features an LCD display, three indicators, and four function keys to show operating status and input/output power information.

Close-up of LCD display and function buttons
LCD display and function buttons: ESC, UP, DOWN, ENTER.

LED Indicator Meanings:

Indicator LED Color Status Message
AC/INV Green Solid On Output is powered by utility in Line mode.
Flashing Output is powered by battery or PV in battery mode.
CHG Green Solid On Battery is fully charged.
Flashing Battery is charging.
FAULT Red Solid On Fault occurs in the inverter.
Flashing Warning condition occurs in the inverter.

Function Keys:

Function Key Description
ESC To exit setting mode
UP To go to previous selection
DOWN To go to next selection
ENTER To confirm the selection in setting mode or enter setting mode

4.3. LCD Setting

Press and hold the ENTER button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.

The manual provides detailed tables for various settings including Output Source Priority, Maximum Charging Current, AC Input Voltage Range, Battery Type, Auto Restart, Output Voltage, Output Frequency, Auto Bypass, Maximum Utility Charging Current, Setting Voltage Point (Utility/Battery), Modbus ID, Bulk Charging Voltage, Floating Charging Voltage, Low DC Cut-off Voltage, Bulk Charging Time, Battery Equalization, Battery Equalized Time, Battery Equalized Timeout, Equalization Interval, Neutral and Grounding Connection, Equalization Activation, Automatic/Manual Activation for Lithium Battery, and SOC Point settings.

4.4. Battery Equalization

The equalization function helps prevent stratification and removes sulfate crystals from batteries, extending battery life. It is recommended to equalize batteries periodically.

How to Apply Equalization Function:

  1. Enable battery equalization in LCD setting program 33.
  2. Set equalization interval in program 37, or activate immediately in program 39.

When to Equalize:

In float stage, when the set equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout:

During the Equalize stage, the controller charges the battery until it reaches the battery equalization voltage. Constant-voltage regulation maintains this voltage. If the battery voltage does not reach the equalization voltage within the set time, the charge controller will extend the time. If the voltage is still low after the timeout, equalization stops, and the system returns to the float stage.

4.5. Setting for Lithium Battery

If using a lithium battery, ensure it is a compatible model. There are two connectors on the lithium battery: RS485 port of BMS and power cable.

Lithium Battery Connection Steps:

  1. Assemble battery terminals based on recommended battery cable and terminal size (similar to Lead-acid battery connection).
  2. Connect the RS485 port of the battery to the BMS (RS485) communication port of the inverter.

Lithium Battery Communication and Setting:

Connect the BMS communication cable between the battery and the inverter. This cable transmits information and signals, allowing the inverter to re-configure charging voltage, current, and discharge cut-off voltage based on lithium battery parameters, and to start/stop charging according to battery status.

RS485 Port Pin Assignment:

Pin Number RS485 Port
PIN1 RS485-B
PIN2 RS485-A
PIN7 RS485-A
PIN8 RS485-B

LCD Setting for Lithium Battery:

  1. Select program 05 as lithium battery type.
  2. Confirm program 12/13/29/31/41/42 setting values.

If communication is successful, the LCD will display lithium battery information (e.g., Max charging voltage, Max charging current, SOC%).

Setting for PYLON US2000 Lithium Battery:

Dip Switches (1-4) set baud rate and battery group address. Dip 1 ON for baud rate 9600. Dips 2, 3, 4 are for battery group address. ON=1 (upper position), OFF=0 (bottom position).

Process of Install:

  1. Use the RS485 cable to connect the inverter and Lithium battery.
  2. Switch on the Lithium battery.
  3. Press and hold for more than three seconds to start the Lithium battery for power output.
  4. Turn on the inverter.
  5. Select battery type "Li2" in LCD program 5.

Setting for Lithium Battery without Communication:

If BMS communication is not used, manually set the following based on battery BMS specifications:

  1. Max charging voltage.
  2. Max charging current.
  3. Discharging protection voltage.
  4. Set battery type as "USE" (user-defined) in program 05.
  5. Set C.V voltage as Max charging voltage of BMS - 0.5V.
  6. Set floating charging voltage as C.V voltage.
  7. Set Low DC cut-off voltage ≥ discharging protection voltage of BMS + 2V.
  8. Set Max charging current (less than Max charging current of BMS).
  9. Set voltage point back to utility source (≥ Low DC cut-off voltage + 1V).

Remark:

  1. It is recommended to finish settings without turning on the inverter (LCD should show no output).
  2. After finishing settings, restart the inverter.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter. Perform the following checks periodically:

  • Keep the inverter clean and free from dust. Ensure the detachable dust cover is properly installed in harsh environments.
  • Check all wiring connections for tightness and corrosion. Re-tighten if necessary.
  • Monitor the LCD display for any warning indicators or fault codes. Address any issues promptly.
  • Ensure adequate ventilation around the inverter to prevent overheating. Keep air vents clear.
  • Periodically check battery health and ensure proper equalization cycles are maintained, especially for lead-acid batteries.
  • For lithium batteries, ensure communication with the BMS is active and settings are correct.

6. Troubleshooting

6.1. Fault Reference Code

The inverter displays specific fault codes to indicate issues. Refer to the table below for explanations and corrective actions.

Fault Code Fault Event Icon on
01Over temperature of inverter module01
02Over temperature of DCDC module02
03Battery voltage is too high03
04Over temperature of PV module04
05Output short circuited.05
06Output voltage is too high.06
07Overload time out07
08Bus voltage is too high08
09Bus soft start failed09
10PV over current10
11PV over voltage11
12DCDC over current12
13Over current or surge13
14Bus voltage is too low14
15Inverter failed (Self-checking)15
18Op current offset is too high18
19Inverter current offset is too high19
20DC/DC current offset is too high20
21PV current offset is too high21
22Output voltage is too low22
23Inverter negative power23

6.2. Warning Indicator

The inverter provides audible alarms and flashing icons for various warning conditions.

Warning Code Warning Event Audible Alarm Icon Flashing
02Temperature is too HighBeep three times every second02
04Low batteryBeep once every second04
07OverloadBeep once every 0.5 second07 (OVERLOAD)
10Output power deratingBeep twice every 3 seconds10
14Fan blockedNone14
15PV energy is lowBeep twice every 3 seconds15
19Lithium Battery communication is failedBeep once every 0.5 second19
21Lithium Battery over currentNone21
E9Battery equalizationNoneE9
bPBattery is not connectedNonebP

6.3. General Troubleshooting

Problem Explanation / Possible Cause What to Do
Unit shuts down automatically during startup process. Battery voltage is too low. 1. Re-charge battery. 2. Replace battery.
No response after power on. 1. Battery voltage is far too low. 2. Battery polarity is connected reversed. 1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery.
Input voltage displayed as 0 on LCD and green LED is flashing. Input protector is tripped. Check if AC breaker is tripped and AC wiring is connected well.
Mains exist but unit works in battery mode. Insufficient quality of AC power (Shore or Generator) or "Solar First" is set as output source priority. 1. Check if AC wires are too thin/long. 2. Check generator (if applied) or input voltage range setting. Change output source priority to Utility first.
When unit is turned on, internal relay switches on and off repeatedly. Battery is disconnected. Check if battery wires are connected well.
Buzzer beeps continuously and red LED is on. Fault code 07: Overload error. Fault code 05: Output short circuited. Fault code 02: Inverter component over 100°C. Fault code 03: Battery over-charged or voltage too high. Fault code 06/22: Output abnormal. Fault code 08/09/15: Internal components failed. Fault code 13: Over current or surge. Fault code 14: Bus voltage too low. Reduce connected load. Check wiring and remove abnormal load. Check air flow/ambient temperature. Return to repair center. Check battery specs. Restart unit.

7. Specifications

7.1. Line Mode Specifications

Parameter Value
INVERTER MODEL4.2KVA
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Low Loss Voltage95Vac±7V (UPS); 70Vac±7V (Appliances)
Low Loss Return Voltage100Vac±7V (UPS); 75Vac±7V (Appliances)
High Loss Voltage140Vac±7V
High Loss Return Voltage135Vac±7V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionBattery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

Output Power Derating: When AC input voltage drops to 95V, the output power will be derated.

7.2. Inverter Mode Specifications

Parameter Value
INVERTER MODEL4.2KVA
Rated Output Power4.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation120Vac±5%
Output Frequency50Hz or 60Hz
Peak Efficiency94%
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc
Cold Start Voltage23.0Vdc
No Load Power Consumption<55W
Low DC Warning Voltage (AGM/Flooded)22.0Vdc (<20% load); 21.4Vdc (20-50% load); 20.4Vdc (≥50% load)
Low DC Warning Return Voltage (AGM/Flooded)23.0Vdc (<20% load); 22.4Vdc (20-50% load); 21.2Vdc (≥50% load)
Low DC Cut-off Voltage (AGM/Flooded)21.0Vdc (<20% load); 20.4Vdc (20-50% load); 19.2Vdc (≥50% load)

7.3. Charge Mode Specifications

Parameter Value
INVERTER MODEL4.2KVA
Max Charging Current (PV+AC) (@ VI/P=230Vac)120Amp
Max Charging Current (AC) (@ VI/P=230Vac)60Amp
Bulk Charging Voltage (Flooded Battery)29.2Vdc
Bulk Charging Voltage (AGM / Gel Battery)28.2Vdc
Floating Charging Voltage27Vdc
Overcharge Protection32Vdc
Charging Algorithm3-Step

7.4. Solar Input Specifications

Parameter Value
INVERTER MODEL4.2KVA
Rated Power6200W
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~500Vdc
Max. Input Current27A
Max. Charging Current(PV)120A

7.5. General Specifications

Parameter Value
INVERTER MODEL4.2KVA
Operating Temperature Range-10°C to 55°C
Storage temperature-15°C~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm368 x 312.4 x 120.5
Net Weight, kg7.3

8. User Tips

  • This inverter is an excellent solution for systems that may not require batteries, offering simple and functional operation directly from solar panels.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the Aninerel Flagship Store directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.