1. Introduction
Thank you for choosing the STC-1000 Digital Temperature Controller. This device is designed for precise temperature control in various applications, offering automatic switching between heating and cooling modes. It features a clear digital display, NTC sensor input, and relay outputs for both heating and cooling devices.
Key Features:
- Automatic mode switching between cooling and heating.
- Temperature control by setting target temperature and difference value.
- Temperature calibration function.
- Compressor delay protection for cooling output.
- Alarm for temperature exceeding limits or sensor errors.
2. Setup
2.1. Unpacking
Carefully unpack the STC-1000 controller and ensure all components are present: the controller unit and the NTC temperature sensor probe.
2.2. Mounting
The STC-1000 is designed for panel mounting. Ensure adequate space for ventilation and wiring behind the panel.
- Front Panel Size: 75mm (L) × 34.5mm (W)
- Mounting Size: 71mm (L) × 29mm (W)
- Product Size: 75mm (L) × 34.5mm (W) × 85mm (D)

2.3. Wiring
WARNING: Incorrect wiring can cause damage to the device, connected equipment, or pose an electrical hazard. Ensure power is disconnected before wiring.
- Strictly distinguish the sensor down-lead, power wire, and output relay interface from one another.
- Prohibit wrong connections or overloading the relay.
- Do not connect wire terminals without electricity cut-off.
- The power supply should conform to the voltage value indicated on your specific STC-1000 model (DC 12V, DC 24V, or AC 110-220V).
- To avoid interference, keep the sensor down-lead and power wire separated.
Terminal Block Description:
- Terminals 1 & 2: Power Supply (Connect your chosen voltage supply here).
- Terminals 3 & 4: NTC Sensor (Connect the temperature probe here).
- Terminals 5 & 6: Heating Output (Connect your heating device here).
- Terminals 7 & 8: Cooling Output (Connect your cooling device here).


3. Operating Instructions
3.1. Basic Operation
- Power On/Off: Under normal working status, press and hold the 'power' key (labeled with a circle and vertical line) for 3 seconds to turn off the controller. To turn it on, press and hold the 'power' key for 3 seconds.
- Display: The screen displays the current measured temperature. The controller automatically switches between heating and cooling modes based on your settings.
3.2. Indicator Lights
The STC-1000 has three indicator lights to show its current status:
| Indicator Light | Status | Description |
|---|---|---|
| Cool | On | Refrigeration starts |
| Off | Refrigeration stops | |
| Flashing | Compressor delay protection active | |
| Heat | On | Heating starts |
| Off | Heating stops | |
| Set | On | Parameter setting mode is active |
Note: The 'Cool' and 'Heat' indicator lights cannot be on simultaneously.
3.3. Parameter Setting
To configure the controller's behavior, you need to access the parameter setting menu:
- Under normal working status, press and hold the 'S' key for 3 seconds or more to enter parameter modifying mode. The 'Set' indicator light will turn on, and the screen will display the first menu code 'F1'.
- Press the 'Up' (▲) or 'Down' (▼) key to navigate through menu items (F1, F2, F3, F4).
- To view a parameter's value, press the 'S' key. To adjust the value, press and hold 'S' then use the 'Up' (▲) or 'Down' (▼) keys. Release 'S' to save the new value.
- If no key operation occurs within 10 seconds in setting mode, the system will automatically save any changes and return to the normal temperature display status.
Menu Functions:
| Code | Function | Set Range | Default |
|---|---|---|---|
| F1 | Temperature set value | -50 ~ 99°C | 10°C |
| F2 | Difference set value | 1 ~ 10°C | 3°C |
| F3 | Compressor delay time | 1 ~ 10 minutes | 3 minutes |
| F4 | Temperature calibration | -10 ~ 10°C | 0°C |

4. Maintenance
4.1. Cleaning
Ensure the controller and its display are kept clean and free from dust. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
4.2. Sensor Care
The NTC sensor is a critical component for accurate temperature measurement. To avoid interference and ensure longevity, keep the sensor down-lead and power wire separated. Avoid placing the sensor in environments with strong electromagnetic interference or corrosive substances.
5. Troubleshooting
5.1. Error Descriptions
- Sensor Error (EE):
When the sensor is open circuit or short circuit, the controller activates the sensor error alarm mode. All running status is closed off with the buzzer alarms, and the display shows 'EE'. Press any key to cancel the alarm sound. The display will return to normal temperature when the error is cleared. - Over-temperature Alarm (HH):
When the measuring temperature exceeds the temperature measuring range, the controller activates the error alarm function. All running status is closed off with the buzzer alarms, and the display shows 'HH'. Press any key to cancel the alarm sound. The display will return to normal temperature when the error is cleared. - System Restore (Er):
When electrified, the system will self-check. If 'Er' appears, press any key to restore default values and enter normal working mode. It is advised to reset parameter values under this condition.
6. Specifications
| Parameter | Value |
|---|---|
| Product Name | Temperature Controller |
| Product Model | STC-1000 |
| Supply Voltage | DC12V, DC24V, or AC110-220V (model dependent) |
| Temperature Range | -50 ~ +99°C |
| Temperature Measurement Accuracy | ±1°C (in the range of -50 ~ +70°C) |
| Resolution | 0.1°C |
| Sensor Type | NTC sensor (1Pcs) |
| Sensor Cable Length | 1 meter |
| Relay Contact Capacity | Cool 10A/250VAC; Heat 10A/250VAC |
| Power Consumption | ≤3W |
| Ambient Temperature | 0 ~ 60°C |
| Storage Temperature | -30 ~ 75°C |
| Relative Humidity | 20% ~ 85% (No condensate) |
| Front Panel Size | 75mm (L) × 34.5mm (W) |
| Mounting Size | 71mm (L) × 29mm (W) |
| Product Size | 75mm (L) × 34.5mm (W) × 85mm (D) |

7. User Tips
- Voltage Compatibility: Always ensure you have the correct STC-1000 model for your power supply (DC 12V, DC 24V, or AC 110-220V) to prevent damage to the unit and connected devices.
- Sensor Placement: For accurate readings and to avoid interference, position the temperature sensor away from direct heat sources, strong electromagnetic fields, and keep its wiring separate from power lines.
- Temperature Calibration: If you suspect your temperature readings are inaccurate, use the F4 parameter to calibrate the sensor against a known accurate thermometer.
- Compressor Protection: Utilize the F3 (Compressor delay time) setting to protect your refrigeration equipment from short-cycling, which can extend its lifespan.
8. Warranty and Support
For warranty details, please refer to the documentation provided with your purchase or contact your retailer. For technical support, please reach out to the seller or manufacturer.