1. Product Overview
Thank you for choosing the GD series MPPT controller. This new generation MPPT controller is developed based on the latest technology, representing the forefront of photovoltaic technology. It offers superior performance characteristics:
- Excellent heat dissipation design with an intelligent control cooling fan.
- Innovative Maximum Power Point Tracking (MPPT) technology significantly improves solar energy system efficiency, with a conversion efficiency of up to 97%.
- Rapidly scans the entire I-V curve to track the maximum power point within seconds.
- Supports three types of batteries: sealed lead-acid, colloidal, and open type, with corresponding charging programs.
- Automatic protection functions for overcharging, overdischarging, overload, and short circuit.
- RS485 communication interface for multi-machine communication, with a range of up to 1km, allowing convenient monitoring of operating parameters via a computer.
Characteristics of Maximum Power Point Tracking Technology
The GD series MPPT controller automatically extracts maximum power from the solar array for battery charging. This method is fully automatic and requires no user adjustment. The controller continuously tracks the maximum power point of the array, even with changing environmental conditions, to ensure optimal energy harvesting.
Increase Current: If the MPPT voltage (Vmp) of the solar array exceeds the battery voltage, the charging current to the battery will be proportionally greater than the output current of the solar array to balance input and output power. A larger difference between Vmp and battery voltage results in greater current enhancement, which is crucial as Vmp is typically higher than battery voltage in solar power generation systems.
Advantages over Traditional Controllers: Traditional controllers directly connect the solar array to the battery, requiring the solar array to operate below Vmp. MPPT controllers offer a significant advantage by optimizing power acquisition, even in hot weather, by ensuring the photovoltaic modules' nominal voltage is higher than the battery pack's voltage and by reducing wiring current.
Figure 1: Product Characteristics highlighting MPPT technology, 3-stage charging, and various protections.
Figure 2: Illustration of 3-stage charging optimizing battery performance and various solar panel applications.
2. Safety Instructions & Precautions
Before installing and operating the controller, please read and keep this manual for future reference. All work on the charging controller must be carried out by technical personnel.
General Safety Precautions
- Warning! The input voltage range of this controller is large. Operate with caution to avoid personal injury.
- This device should not be operated by children or individuals lacking physical or psychological abilities, or experience. Keep away from children.
- Warning! High temperature shell components. Install in an environment with good heat dissipation and ventilation.
- Warning! Radiation can harm health. Do not stay near solar charging controllers less than 20 centimeters away for a long time.
- Ensure the input DC voltage does not exceed the specified maximum voltage to prevent permanent damage. Such damage is not covered under warranty.
- If technicians need to maintain or clean the solar controller or connect it to circuits, they must follow relevant safety steps.
- Use only components recommended or sold by the manufacturer.
- Ensure existing lines have good conditions and suitable wire sizes to avoid fire and electric shock. Do not operate if the controller is damaged or wiring is not qualified.
- Do not disassemble or attempt to repair the solar charging controller yourself, as this may cause further damage, accidents, and void the warranty.
- Keep away from flammable and explosive materials.
- Install in a location away from damp or corrosive substances.
- Use insulated tools to operate the equipment to avoid short circuits.
Figure 3: Overview of 12 performance features, including safety considerations like professional installation, heat dissipation, and various protections.
3. Setup (Installation & Wiring)
Installation must be completed by professional technicians.
3.1 Selection of Installation Location
- Install on a solid surface.
- The installation location must be accessible at all times and allow for removal.
- Ambient temperature should be between -20°C and +50°C for optimal working environment.
- Do not install in direct sunlight to avoid power loss due to overheating.
- Danger: The controller chassis becomes hot during operation. Do not install on flammable building materials or near highly flammable materials. Avoid areas with potential explosion hazards.
- Warning: Due to built-in thermal storage module components, do not touch the controller with bare hands after opening the casing during operation.
3.2 Safety Distance
Observe the following safety clearances to ensure sufficient heat dissipation space:
| Description | Safe Distance |
|---|---|
| Side | 20CM |
| Top | 30CM |
| Bottom | 30CM |
Figure 4: Diagram illustrating recommended safety clearances for controller installation.
3.3 Wiring Steps
Warning: Short circuits between the positive and negative terminals of the battery and connected wires pose a risk of fire or explosion. Handle with caution.
Dangerous! Incorrect high voltage input operation can be life-threatening. Use a circuit breaker to disconnect the solar panel array and avoid accidental power activation. Disconnect the circuit breaker and ensure no voltage is present in the system.
Warning: Overvoltage can damage the system. Thunderstorms and lightning increase the risk of damage to external overvoltage protection systems.
Attention: Connecting the battery pack must be done with the circuit breaker disconnected.
Figure 5: General wiring diagram for the solar charging system, showing connections between solar panel, MPPT controller, battery, and DC load.
Warning: Electric shock hazard! Photovoltaic modules may generate high voltage. Be careful to prevent electric shock when wiring.
The controller supports off-grid solar modules of 12V, 24V, and 48V, as well as grid-connected modules with an open circuit voltage not exceeding the specified maximum input voltage. The voltage of the solar modules in the system should not be lower than the system voltage.
Attention: Connecting photovoltaic modules must be done with the circuit breaker disconnected.
3.4 Cable and Circuit Breaker Specifications
| Model | GD-50A | GD-60A | GD-80A | GD-100A | GD-120A |
|---|---|---|---|---|---|
| Cable (copper) | 10mm² | 16mm² | 16mm² | 25mm² | 25mm² |
| Circuit breaker | 63A | 80A | 100A | 125A | 125A |
3.5 Temperature Sensor and PC Connection
An RS485 communication cable is an optional component. If needed, install the upper computer software (purchased separately). Detailed usage and installation instructions are provided with the accessories.
Figure 6: Diagram showing connections for temperature sensor, PC, and USB to the controller.
3.6 Power On Trial Operation
Attention: Before powering on for trial operation, ensure all DC connection wires have their positive and negative poles correctly connected.
- Check that the positive and negative terminals of the connecting wire are fully connected. Measure the open circuit voltage of the photovoltaic module to ensure it is within the controller's working range.
- First, turn on the circuit breaker connecting the controller to the battery.
- Then, open the circuit breaker connecting the controller to the solar panel.
- The controller will enter self-test mode. If system conditions are correct, it will automatically enter working mode. If conditions are incorrect, the controller will display a fault prompt; refer to the troubleshooting section to resolve.
- The factory default battery type is maintenance-free lead-acid. Refer to battery type settings for adjustments.
4. Operating Instructions
4.1 Panel Component Description
Figure 7: Diagram of the controller's front panel with numbered components.
| Number | Name | Number | Name |
|---|---|---|---|
| 1 | LCD display screen | 5 | Junction box cover plate |
| 2 | Charging indicator light | 6 | Flip up button |
| 3 | Function menu button | 7 | Confirm button |
| 4 | Flip down button | 8 | DC output indicator light |
4.2 Indicator Light Status Description
| Name | State | Status Description |
|---|---|---|
| Charge Indicator | Flash mob | Charging in maximum power tracking mode |
| Slow flashing | Floating charging mode charging | |
| Extinguish | Stop charging | |
| DC Output Indicator Light | Bright | Normal output |
| Dodge | Battery undervoltage prompt | |
| Extinguish | Turn off output |
4.3 LCD Display Screen Description
The LCD display provides real-time information about the controller's status and parameters.
Figure 8: Close-up of the LCD display, discharge outlet, line interface, and product parameter label.
Main Interface: The default main interface displays various parameters. Use the DOWN or UP key to scroll through the screen.
Main Menu: Press the MENU key to enter the main menu. Use the DOWN or UP key to view submenus. The main menu options include:
- Run parameter settings
- Time and date settings
- Contrast setting
- Brightness setting
- Sound settings
- Record query
- Clear Record
- DC output setting
- Communication settings
- Language settings
4.4 Operating Parameter Settings
Attention: Setting operating parameters must be done by professional technicians. Incorrect operation may cause malfunction or damage to the battery.
From the default main interface, press MENU to enter the main menu. Use DOWN to select 'running parameter settings', then press ENTER to access the password prompt. Enter the password and press ENTER to proceed to the running parameter settings.
- Battery Type Settings: In the operation parameter interface, press ENTER to enter battery type setting. Use DOWN to select the battery type (lead-acid maintenance free, gel battery, liquid battery, lithium battery series). Press ENTER to confirm and MENU to return. The factory default is maintenance-free lead-acid batteries.
- Rated Battery Voltage Setting: Select 'rated voltage setting' in the operation parameter interface. Press ENTER to choose the rated voltage level (automatic recognition, 12V, 24V, 36V, 48V...). Press ENTER to confirm. The factory default automatically identifies the rated voltage level for lead-acid batteries. For lithium batteries, manual setting is required to adjust charging and discharge lower limit voltages.
- Charging Voltage Setting: Select 'charging voltage setting'. Press ENTER, use UP/DOWN to adjust the value, then ENTER to confirm. For lithium batteries, only float charging (constant voltage) mode is available.
- Charging Current Setting: Select 'charging current setting'. Press ENTER, use UP/DOWN to adjust the value, then ENTER to confirm. The set value cannot exceed the current maximum value.
- Discharge Limit Setting: This sets the cut-off voltage and resumption voltage of the DC output. Select 'discharge limit setting'. Press ENTER, use UP/DOWN to adjust the value, then ENTER to confirm.
- Factory Reset: Select 'restore factory settings'. Press ENTER to choose whether to restore. Confirm with ENTER. This can resolve issues from incorrect parameter settings.
- Password: To enter running parameter settings, press DOWN 3 times, then UP 3 times, then ENTER.
- Time and Date Settings: From the main menu, select 'time settings'. Press ENTER, use UP to move the cursor, DOWN to modify values, then ENTER to confirm.
- Contrast Setting: From the main menu, select 'contrast settings'. Press ENTER, use DOWN to reduce, UP to increase, then ENTER to confirm.
- Brightness Settings: Similar to contrast settings.
- Sound Settings: From the main menu, select 'sound settings'. Press ENTER to choose button sound on/off or alarm sound on/off, then ENTER to confirm.
- Record Query: From the main menu, select 'record query'. Press ENTER to choose curve record query or fault record query. Use UP/DOWN to query records.
- Clearing Records: From the main menu, select 'clear records'. Press ENTER to choose whether to clear, then ENTER to confirm.
- DC Output Settings: From the main menu, select 'DC output settings'. Press ENTER to choose off, automatic, time control, or light control. 'Off' turns off DC output. 'Automatic' turns on DC output after battery connection. Time control allows setting specific on/off times.
- Communication Settings: From the main menu, select 'communication settings'. Press ENTER to choose baud rate or local address settings. Use DOWN to set values, then ENTER to confirm.
- Language Settings: From the main menu, select 'language settings'. Press ENTER to choose the language, then ENTER to confirm.
5. Maintenance and Cleaning
5.1 Replacing Fuses
If the fuse burns out due to high temperature or other malfunctions, it must be replaced correctly. Remove the broken fuse from the interface, install a new fuse, ensure it is connected correctly, and then reinstall the device. The fuse is located near the wiring junction.
5.2 Cleaning Ventilation Vents and Heat Sinks
Regularly clean the fan vents and internal heat sinks by wiping them with a dry or slightly damp cloth. Do not use detergent or corrosive solvents for cleaning. Do not allow liquid to flow into the machine, and ensure that the ventilation holes are not blocked.
6. Troubleshooting
If the controller encounters an abnormality, check the following items before contacting customer service.
| Abnormal Phenomenon of Malfunction | Solution |
|---|---|
| MPPT controller powers on for the first time, and the fault prompt is: battery voltage exceeds the normal recognition range. |
|
| Fault prompt: Over temperature protection |
|
| Fault prompt: Battery overdischarge protection | The battery has run out of energy. |
| Fault prompt: No external temperature sensor detected | Ensure the temperature sensor is correctly connected and functional. |
| The charging indicator light is not on and there is no charging current or charging power display. |
|
| The charging indicator light lights up briefly and then goes out quickly, and the charging current is sometimes intermittent. | This situation usually occurs on cloudy days or in the evening when there is insufficient sunlight, which is a normal phenomenon. |
| No power curve and current curve display. | Check if the time and date displayed on the MPPT controller are correct (refer to time and date settings). |
If the problem persists after following the above table, please contact customer service. Provide the following information: equipment model, order number, serial number (from the back panel), and a detailed description of the problem (e.g., system type, frequency, indicator lights, display status).
7. Specifications
7.1 Technical Parameters
| Parameter | Details |
|---|---|
| Model | GD-50/60/80/100/120 column |
| Charge Mode | MPPT automatic maximum power point tracking |
| Charging Method | Three stages: constant current (MPPT), balanced charging, and float charging |
| System Type | 12V-24V/12V-48V (Automatic recognition/manual setting) |
| System Identification Voltage Range | 12V system: DC9V-DC15V 24V system: DC18V-DC30V 48V system: DC36V-DC60V |
| Soft Start Time | ≤10s |
| Dynamic Response Recovery Time | ≤500us |
| Static Power Consumption | ≤2W |
| Efficiency | ≥ 96.5% |
| Utilization Rate of Photovoltaic Modules | ≤99.97% |
| MPPT Operating Voltage Range | 12V system: DC18V-DC 100V 24V system: DC34V-DC 100V 48V system: DC65V-DC150V |
| Input Low Voltage Protection Point | 12V system: DC16V 24V system: DC30V 48V system: DC60V |
| Input Low Voltage Recovery Point | 12V system: DC18V 24V system: DC34V 48V system: DC65V |
| Extreme Input Voltage | DC170V (40A:95V) |
| Input Overvoltage Protection Point | DC175V (40A:100V) |
| Input Overvoltage Recovery Point | DC170V (40A:95V) |
| Maximum Solar Panel Input Power | 12V system: 600W (50A), 720W (60A), 960W (80A), 1200W (100A), 1440W (120A) 24V system: 1200W (50A), 1440W (60A), 1920W (80A), 2400W (100A), 2880W (120A) 48V system: 2400W (50A), 2880W (60A), 3840W (80A), 4800W (100A), 5760W (120A) 96V system: 4800W (50A), 5760W (60A), 7680W (80A), 9600W (100A), 11520W (120A) |
| Optional Battery Types | Lead acid maintenance free batteries, colloidal batteries, liquid batteries, lithium batteries (customizable) |
| Floating Voltage (lead-acid battery) | 12V system: 13.8V 24V system: 27.60V 48V system: 55.20V (customizable) |
| Uniform Charging Voltage (lead-acid battery) | 12V system: 14.5V 24V system: 29V 48V system: 58V (customizable) |
| Rated Current | 50A, 60A, 80A, 100A, 120A |
| Current Limiting Protection | 52A (50A), 62A (60A), 82A (80A), 102A (100A), 122A (120A) |
| Temperature Coefficient | ±0.02%/°C |
| Automatic Temperature Compensation | 14.2V - (maximum temperature - 25°C) * 0.3 |
| Output Voltage Stabilization Accuracy | ≤ ±1.5% |
| LCD Display | Refer to LCD display instructions for details |
| LED Display | Charging indicator, DC output switch status indicator |
| PC Upper Computer (Communication Port) | RS485 (optional) |
| Input Low Voltage Protection | Refer to input characteristics |
| Input High Voltage Protection | Refer to input characteristics |
| Input Polarity Reversal Protection | Capable of polarity reversal protection |
| Output Polarity Reverse Protection | Capable of polarity reversal protection |
| Short Circuit Protection | After 5 trial starts, it enters the protection state and recovers from the start |
| Audio Noise | <50dB |
| Heat Dissipation Method | Forced air cooling; fan speed adjusted by temperature. Fan runs slowly or stops when internal temperature is low. Fan stops when controller stops working. |
| Element | Imported materials complying with EU standards; electrolytic capacitors rated for ≥105°C. |
| Odor | No odor or harmful to health |
| Environmental Requirements | Meets 2002/95/EC; No cadmium, hydrides, and fluorides |
| Humidity | 0~90% RH (no condensation) |
| Altitude | 0~3000m |
| Ambient Temperature | -20°C ~ +40°C |
| Storage Temperature | -40°C ~ +70°C |
| Atmospheric Pressure | 70~106kPa |
7.2 Dimensions
Figure 9: Controller dimensions: 162mm (width) x 237mm (height) x 80mm (depth).
7.3 Photovoltaic Power Conversion Efficiency Curve
Figure 10: Comparison diagram illustrating the higher power generation capacity of MPPT controllers compared to traditional PWM controllers (Daily, Monthly, Annual).
The manual also includes detailed efficiency curves for various system voltages (12V, 24V) and photovoltaic module voltages (17V, 34V, 68V). These curves demonstrate the controller's performance under different operating conditions.
8. Warranty and Support
8.1 Quality Assurance
Products malfunctioning during the quality assurance period will be repaired or replaced with new products free of charge by our company.
Evidence: During the warranty period, customers must provide invoices and purchase dates. The product's trademark must be clearly visible; otherwise, the right to quality assurance may be denied.
Conditions for Replacement: The replacement of non-conforming products will be handled by our company. Customers should allow reasonable maintenance time for repairs.
8.2 Warranty Exclusions
The company reserves the right not to provide quality assurance in the following situations:
- The entire machine and components have exceeded the free warranty period.
- Damage caused during transport.
- Incorrect installation or modification for use.
- Operating in extremely harsh environments beyond those described in this manual.
- Machine malfunctions or damages caused by non-company service agencies, repairs, modifications, or dismantling.
- Damage caused by abnormal natural environment.
If a malfunction is caused by the above situations, the customer may request paid maintenance services after assessment by our service agency.
9. User Tips
No specific user tips were available from provided reviews or Q&A content.