1. Product Overview

The Solenoid Valve is a precision electromagnetic control component widely used in industrial automation, fluid control systems, and vehicle equipment (such as commercial vehicle air suspension, braking systems, and hydraulic circuits). It uses electromagnetic force to control the opening and closing of the valve core, thereby regulating the on-off, flow, and direction of fluids (air, oil, water, etc.). This product features quick response, stable performance, high control accuracy, and strong adaptability, ensuring reliable operation in harsh working environments such as high temperature, low temperature, and high pressure.

Key Functions:

  • Fast on-off control of fluids (gas, liquid)
  • Precise flow and pressure regulation (for proportional solenoid valves)
  • Automatic control with electrical signals, easy to integrate with control systems
  • Low power consumption, long service life, and stable operation
  • Anti-corrosion, anti-interference, and suitable for various working conditions
Air Suspension Solenoid Valve Block, top view
Top view of the Solenoid Valve Block.
Air Suspension Solenoid Valve Block, side view
Side view of the Solenoid Valve Block.
Air Suspension Solenoid Valve Block, angled view with labels
Angled view showing port labels (FR, RAX, FL).
Air Suspension Solenoid Valve Block, electrical connector
Close-up of the 10-pin electrical connector.

2. Safety Instructions

WARNING:

  • Installation, wiring, maintenance, and replacement must be performed by qualified technicians or electricians. Unauthorized operations may cause electric shock, equipment damage, or fluid leakage.
  • Before any operation, cut off the power supply and release all fluid pressure in the system to avoid accidental activation of the solenoid valve or fluid spray injury.
  • Do not exceed the maximum operating voltage, pressure, or temperature specified in the technical parameters. Overload may cause coil burnout, valve core jamming, or explosion.
  • Keep the solenoid valve away from flammable, explosive, and corrosive substances. Do not use it in explosive environments unless it is an explosion-proof model.
  • Do not touch the coil immediately after operation, as it may be hot and cause burns.
  • Ensure correct wiring polarity (for DC solenoid valves). Reverse polarity will damage the coil or cause the valve to fail to work.
  • Do not disassemble the solenoid valve arbitrarily, as internal components are precision parts and improper disassembly may cause irreversible damage.

CAUTION:

  • Incorrect installation or wiring may lead to valve malfunction, fluid leakage, or damage to the control system.
  • Regularly inspect the valve body and connections for leaks, wear, or damage. Replace damaged parts in a timely manner.
  • Avoid using fluids containing impurities (such as dust, particles, or sediment), as they may block the valve core and affect performance. Install a filter in the fluid pipeline if necessary.
  • If the solenoid valve is not used for a long time, cut off the power supply and drain the internal fluid to prevent corrosion or jamming.
  • Use only compatible fluids. Incompatible fluids may damage the seal and valve body.

3. Setup Instructions

3.1 Preparation

  • Park the equipment (or shut down the system) on a stable, level surface, cut off the power supply, and release all fluid pressure in the pipeline.
  • Gather required tools: wrench, torque wrench, thread sealant (approved for fluid systems), wire stripper, screwdriver, and filter (if applicable).
  • Inspect the new solenoid valve for damage, missing parts, or fluid leakage. Ensure the model, voltage, and connection size match the system requirements.
  • Clean the pipeline interface to remove rust, dirt, and debris, ensuring smooth fluid flow and tight connection.

3.2 Mounting

  1. Mount the solenoid valve on a stable bracket or pipeline using the provided mounting holes. Ensure the valve is installed vertically or horizontally (follow the direction marked on the valve body; do not install upside down).
  2. Align the valve's inlet and outlet ports with the pipeline interface. The direction of fluid flow must be consistent with the arrow marked on the valve body; reverse installation will cause valve failure.
  3. Use a wrench to connect the valve to the pipeline. Apply a small amount of approved thread sealant to the threaded interface (do not use excessive sealant to avoid blocking the valve core). Tighten to the specified torque (15-25 Nm for G1/4" threads; adjust according to thread size).
  4. If the system requires it, install a filter at the inlet of the solenoid valve to prevent impurities from entering the valve body.

3.3 Wiring

  1. Confirm the power supply voltage matches the solenoid valve's rated voltage (DC/AC, voltage value).
  2. Strip the ends of the power wires (about 5mm) and connect them to the solenoid valve's terminal block. For DC solenoid valves, connect the positive wire to the "V+" terminal and the negative wire to the "V-" terminal; for AC solenoid valves, there is no polarity requirement.
  3. Secure the wires with terminal screws to avoid loose connections, which may cause poor contact or coil burnout.
  4. Use a cable gland to fix the power cable to the valve body, preventing water, dust, or other impurities from entering the coil housing.
  5. Double-check the wiring polarity (for DC models) and connection tightness before powering on.

3.4 Post-Installation Inspection

  1. Reconnect the power supply and slowly restore the fluid pressure to the normal operating range.
  2. Activate the solenoid valve through the control system (or manual switch) and check if it operates smoothly (you should hear a clear "click" sound when the valve opens or closes).
  3. Inspect all connections for fluid leaks. Use soapy water to check threaded interfaces; if bubbles appear, tighten the connection or reapply thread sealant.
  4. Test the valve's on-off function 3-5 times to ensure stable performance. Check if the fluid flow is smooth and meets the system requirements.

4. Operating Instructions

4.1 Normal Operation

  • The solenoid valve is controlled by electrical signals (on/off signal or analog signal for proportional valves). When the coil is energized, electromagnetic force pulls the valve core, opening or closing the valve port to control fluid flow.
  • For Normally Closed (NC) models: The valve is closed when the coil is de-energized, and opens when energized.
  • For Normally Open (NO) models: The valve is open when the coil is de-energized, and closes when energized.
  • For proportional solenoid valves: The opening degree of the valve core is adjusted by the intensity of the electrical signal, thereby regulating the fluid flow and pressure.
  • During operation, ensure the power supply is stable and the fluid pressure/temperature is within the specified range.

4.2 Manual Operation (if equipped)

  • Some models are equipped with a manual override button for emergency operation when there is no power supply.
  • Press and hold the manual override button to open the valve (for NC models) or close the valve (for NO models). Release the button to return to automatic electrical control mode.
  • Do not use the manual override button for long-term operation; it is only for emergency use.

4.3 Notes on Operation

  • Avoid frequent on-off operation of the solenoid valve (more than 10 times per minute), as this will shorten the service life of the coil and valve core.
  • If the valve fails to operate (no sound, no fluid flow), cut off the power supply immediately and check the wiring, power supply, and valve core for jamming.
  • Do not operate the valve beyond the specified pressure or temperature range, as this may cause seal damage or valve failure.
  • During system maintenance, cut off the power supply and release fluid pressure before operating the solenoid valve.

5. Maintenance Instructions

5.1 Regular Inspection

  • Daily: Visually inspect the valve body for fluid leaks, damage, or abnormal noise during operation. Check the power cable for wear or damage.
  • Weekly: Clean the valve body and pipeline interface to remove dust, dirt, and debris. Check the tightness of wiring and pipeline connections.
  • Monthly: Inspect the filter (if equipped) and clean or replace it if clogged. Check the seal for aging, cracking, or leakage; replace if necessary.
  • Quarterly: Test the valve's response time and on-off performance. Check the coil temperature during operation (should not be excessively hot).
  • Annually: Perform a comprehensive inspection of the solenoid valve, including disassembly (if necessary) to clean the valve core and internal components. Replace worn parts (seals, valve core) with genuine parts.

5.2 Cleaning

  • Cut off the power supply and release fluid pressure before cleaning.
  • Use a clean, dry cloth to wipe the valve body and coil housing to remove dust, dirt, and oil stains.
  • If the valve core is clogged, disassemble the valve (only if instructed) and clean it with clean fluid (consistent with the system fluid). Do not use harsh chemicals or solvents.
  • Clean the filter regularly (if equipped) to ensure smooth fluid flow.
  • After cleaning, reassemble the valve correctly and ensure all connections are tight.

5.3 Repair and Replacement

  • Disassemble the solenoid valve only when necessary and in accordance with this manual. Improper disassembly will damage precision components and void the warranty.
  • Worn or damaged parts (seals, valve core, coil, terminal block) must be replaced with genuine parts to ensure compatibility and performance.
  • Replace the solenoid valve in the following cases: coil burnout, severe valve core wear, irreparable seal damage, frequent jamming, or service life exceeding the specified limit.
  • When replacing the valve, cut off the power supply and release fluid pressure first. Disconnect the pipeline and wiring, then install the new valve according to the installation instructions.
  • After repair or replacement, perform a post-installation inspection and test to ensure the valve operates normally.

6. Troubleshooting

SymptomPossible CauseSolution
Valve does not operate (no click sound)Power supply failure, wrong wiring, coil burnout, or poor contactCheck power supply and wiring, replace burned coil, tighten terminal connections
Fluid leakageLoose connections, damaged seal, or valve core wearTighten connections, replace seal or valve core
Valve jams (cannot open/close)Impurities in fluid, valve core wear, or low voltageClean valve core, install filter, check power supply voltage, replace worn parts
Coil overheatsOvervoltage, long-term continuous operation, or poor heat dissipationAdjust voltage to rated value, reduce continuous operation time, improve heat dissipation
Unstable fluid flow/pressureClogged filter, valve core wear, or proportional signal instability (for proportional valves)Clean/replace filter, replace valve core, check control signal

7. Specifications

Technical Parameters:

  • Valve Type: 2/2 Way (Normally Open/Normally Closed) / 3/2 Way (depending on model)
  • Operating Voltage: DC 12V / 24V (common) or AC 110V / 220V (depending on model)
  • Operating Pressure: 0.1-10 bar (1.45-145 psi)
  • Flow Rate: 5-50 L/min (depending on valve size)
  • Operating Temperature: -20°C to +80°C (-4°F to +176°F)
  • Valve Body Material: Brass / Stainless Steel 304 / Aluminum Alloy
  • Seal Material: Nitrile Rubber (NBR) / Fluorine Rubber (FKM) / Silicone Rubber
  • Protection Class: IP65 / IP67 (depending on model)
  • Response Time: ≤50ms
  • Service Life: ≥1,000,000 cycles
  • Connection Type: Threaded (G1/8", G1/4", G3/8", G1/2") / Flange (depending on model)

Product Dimensions and Weight:

  • Item Length: 13 cm
  • Item Width: 9 cm
  • Item Height: 9 cm
  • Item Weight: 0.4 kg (Package Weight: 0.7 kg)

OEM Part Numbers:

  • LR070245
  • LR037081
  • LR176325

Compatible Vehicle Models:

  • For Land Rover Discovery V (L462): 2.0 Si4 4x4, 3.0 SCV6 4x4, 3.0 P360 MHEV 4x4
  • For Land Rover Range Rover Velar (L560): 2.0 P250 Si4 4x4, 2.0 P300 Si4 4x4, 3.0 P340 SCV6 4x4, 3.0 P340 MHEV, 3.0 P380 SCV6 4x4, 3.0 P400 MHEV 4x4
  • For Land Rover Range Rover IV (L405): 2.0 P400e Hybrid 4x4, 3.0 SCV6 4x4, 3.0 TDV6 4x4, 3.0 SDV6 Hybrid 4x4, 3.0 P360 MHEV 4x4, 3.0 P400 MHEV 4x4, 5.0 V8 4x4, 5.0 SCV8 4x4
  • For Land Rover Range Rover Sport II (L494): 2.0 GTDI 4x4, 2.0 SD4 4x4, 2.0 Si4 4x4, 2.0 P400e PHEV 4x4, 3.0 SCV6 4x4, 3.0 TDV6 4x4, 3.0 SDV6 Hybrid 4x4, 3.0 P360 MHEV 4x4, 3.0 P400 MHEV 4x4, 5.0 SCV8 4x4
  • For Land Rover Defender (L663): 2.0 D240 SD4 4x4, 2.0 P300 Si4 4x4, 2.0 P400e Hybrid 4x4, 3.0 P400 Mild Hybrid 4x4, 5.0 P525 4x4

A PDF version of this manual is available for download from the seller's product page.

8. User Tips

  • Always ensure the fluid system is clean and free of debris before installing the solenoid valve to prevent blockages and ensure optimal performance.
  • Regularly check for any unusual noises or vibrations during operation, which could indicate a potential issue.
  • When troubleshooting, always start by checking the power supply and electrical connections before inspecting the valve's mechanical components.

9. Warranty and Support

9.1 Warranty

This Solenoid Valve is warranted against defects in materials and workmanship for a period of 12 months from the date of purchase. The warranty does not cover damage caused by improper installation, wiring errors, misuse, overload, neglect, unauthorized repair or disassembly, or natural wear and tear.

9.2 Disposal Instructions

  • Dispose of the old solenoid valve and its components in accordance with local environmental protection regulations. Do not discard it as ordinary garbage.
  • Drain all internal fluid before disposal and hand it over to a professional waste treatment agency for proper handling.
  • Metal components (valve body, coil housing) can be recycled in accordance with local recycling regulations.
  • Do not incinerate the solenoid valve, as the coil may produce harmful gases and pollute the environment.
  • Dispose of the coil (containing copper wire) in accordance with electronic waste disposal regulations.

9.3 Customer Support

For any inquiries, customization requests, or bulk orders, please contact our customer service team:

24-Hours Customer Service contact information
Contact details for customer service.
  • Mobile: +86-13906874947
  • E-mail: zhangyf@he-meng.com
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.