SNDWAY H-D510G

Contents

SNDWAY Laser Distance Meter Digital Rangefinder User Manual

Models: H-D510G, H-D710G, H-D100G, H-D120G

Introduction

Thank you for choosing the SNDWAY Laser Distance Meter. This versatile tool combines laser ranging with a traditional tape measure, offering precise measurements for various applications. This manual provides detailed instructions for safe and effective use of your device.

SNDWAY Laser Distance Meter with various measurement functions
Product overview highlighting mechanical tape measure, laser ranging, and various measurement functions.
SNDWAY Laser Distance Meter with key features listed
Key features of the SNDWAY Green Light Laser Distance Meter.

Setup

Unboxing and Package Contents

Please check the package contents against the list below:

No.ItemUnitQTYNote
1Meterpc1
2Portable bagpc1
3Hand strappc1
4User Manualpc1
5Gift Boxpc1
6Type-C Cablepc1
7Reflectorpc1Just available for 100m
Product accessories and parameters
Visual representation of the product accessories.

Battery Installation and Charging

The device features a built-in 3.7V 850mAh lithium battery. It has its own charging circuit with clear undervoltage and charging indications.

  • **Charging Head**: Use a good quality DC5V >0.8A output charging head. Mobile phone charging heads are recommended.
  • **Charging Indication**: The battery symbol will show blank and flash when the battery is low. Insert the USB Type-C cable to charge. The battery symbol will scroll during charging and display a solid icon when fully charged.
Lithium battery with Type-C charging port
The device features a Type-C charging port for its 850mAh lithium battery.

Power On/Off

To turn on the instrument, press the READ key. The instrument will turn on and enter the mode to be tested. To turn off, long press the OFF CLEAR key for 3 seconds. The device will also shut off automatically after 150 seconds of no operation.

Reference Settings

The device allows you to set the measurement reference point. Press and hold the reference key to switch between front-end, mid-end, and back-end reference points. The system default reference point is the bottom.

Unit Settings

Short press the UNIT key to cycle through the available measurement units. There are 6 units for selection:

LengthAreaVolume
10.000 m0.000 m²0.000 m³
20.00 ft0.00 ft²0.00 ft³
30.0 in0.00 in²0.00 in³
40 1/16 in0.00 ft²0.00 ft³
50'00" 1/160.00 ft²0.00 ft³
60.00 ft0.00 ft²0.00 ft³

Sound On/Off

Long press the UNIT button to turn the buzzer sound on or off.

Self-Calibration

This function helps maintain the precision of the device. To enter self-calibration mode:

  1. Ensure the device is off.
  2. Press and hold the OFF CLEAR and READ keys simultaneously until "CAL" appears on the screen.
  3. Adjust the displayed figure using the + and - buttons according to the instrument's error. The adjustment range is from -9mm to +9mm.
  4. Long press the READ button to save the calibration result.

Operating Instructions

The SNDWAY Laser Distance Meter offers multiple measurement modes for various applications. The device features a 2.2-inch large screen for easy reading.

2.2-inch large screen comparison
The 2.2-inch large screen provides easier readability.

Measurement Modes

Press the reference key for a short time to set the measurement mode. Available modes include Area measurement, Volume measurement, Blockage area measurement, and Pythagorean measurement.

Tutorial video demonstrating basic operations including power on, reference settings, unit settings, single measurement, area measurement, continuous measurement, viewing records, sound on/off, self-calibration, and using the mechanical tape measure.

1. Single Distance Measuring

  1. Turn on the laser beam by short pressing the READ button.
  2. Press the READ button again for a single length measurement.
  3. The measured result will be displayed in the major display area.

2. Continuous Measuring

  1. Long press the READ button to enter continuous measuring mode.
  2. The screen displays the maximum and minimum measurement values during this continuous measurement process.
  3. Short press the READ or OFF CLEAR button to exit continuous measuring mode.

3. Area Measurement

  1. Short press the UNIT button until the area measurement icon (a rectangle with blinking side) appears.
  2. Press READ once to measure the length.
  3. Press READ again to measure the width.
  4. The device calculates and displays the area in the major display area.
  5. Press OFF CLEAR to clear the result and measure again, or press UNIT to exit the mode.

4. Volume Measurement

  1. Short press the UNIT button twice until the volume measurement icon (a cube) appears.
  2. Press READ for length, then again for width, and a third time for height.
  3. The device calculates and displays the volume in the major display area.
  4. Press OFF CLEAR to clear the result and measure again, or press UNIT to exit the mode.

5. Pythagorean Measurement

There are four Pythagorean modes to measure targets that are hard to reach. Legs must be shorter than the hypotenuse to avoid "Err" messages. Ensure all measurements start from the same point.

Various measurement applications including single, continuous, area/volume, and angle Pythagorean
Examples of measurement applications: single, continuous, area/volume, and angle Pythagorean.

6. Painter Function

When the meter is in area mode, you can use the add/subtract function to total up the area of several surfaces.

  1. Press the UNIT button three times until the painter icon appears.
  2. Press READ to measure the height of the wall first.
  3. Press READ to measure the bottom edge of the first wall, getting the first area in the major display area.
  4. Press READ to measure the bottom edge of another wall, getting the sum of these two walls.
  5. Repeat these operations for more walls.
  6. Press OFF CLEAR button to clear the previous measuring result and start a new measurement.
  7. When there is no data in the Auxiliary Display area, press UNIT button to exit the mode.

Electronic Angle Sensor

The angle information is displayed at the top of the screen. The angle measurement range is -90.0° to 90.0°. This allows for real-time horizontal reference, making measurements more accurate, especially for vertical and horizontal distances.

Electronic angle sensor showing 45-degree measurement
The electronic angle sensor can measure angles up to ±90°.
Electronic angle sensor for real-time horizontal reference
Real-time horizontal reference using the electronic angle sensor for accurate measurements.

Data Storage

The device has a 100-group data storage function. Long press the SAVE key for 3 seconds to record your measurement result under any measuring mode (Length, Area, Volume, Pythagoras).

100 data storage function display
The device can store up to 100 groups of measurement data.

Mechanical Tape Measure

The mechanical tape measure at the bottom of the instrument can be pulled out to measure shorter distances manually.

Product held in hand, highlighting laser ranging and 2m steel tape measure
The device includes a 2m steel tape measure for close-range measurements.

Green Light Laser Technology

This device utilizes a green light laser, which has a smaller wavelength and higher frequency compared to red light lasers. This results in clearer visibility, especially under sunlight, and contributes to more stable and accurate measurements.

Green light laser wavelength vs red light, and sunlight effect
Comparison of red and green light laser wavelengths and their performance in sunlight.

Triple Laser and Two-Tube Transceiver

The device features a new grade triple laser design and a two-tube transceiver. The triple laser heads ensure stable and accurate measurement. The two-tube transceiver avoids error increase caused by overheating of a single tube and provides millisecond-level high-speed response. It uses OSRAM dual laser tubes for excellent luminous properties and higher-precision long-distance measurements.

New grade triple laser vs dual laser
The new upgrade features a triple laser for stable and accurate measurements.
Two-tube transceiver and OSRAM dual laser tubes diagram
Diagram illustrating the two-tube transceiver with OSRAM dual laser tubes for enhanced accuracy and speed.

Tripod Mounting

The device includes a 1/4 inch screw hole design, allowing it to be installed on triangular frames (tripods) according to different needs. Note: A tripod is not included with this product.

1/4 inch screw hole design for tripod mounting
The 1/4 inch screw hole allows for tripod mounting.

Maintenance

Battery Maintenance

  • Keep the device with full power if it will not be used for a long time.
  • Charge the battery once every half year to avoid damage.

Cleaning

  • Keep the device surface clean. Use a soft, wet cloth to wipe dust from the surface.
  • Do not use corrosive liquids to clean the device.
  • Use the same method as wiping optical devices to clean the meter and focusing mirror.

Troubleshooting

The device may display warning messages. Refer to the table below for common issues and their solutions:

Info MessageCauseSolution
ErrOut of distance measurement rangeUse the device within the specified range.
Err1Signal is too weakChoose a surface with stronger reflectance. Use a reflecting plate if necessary.
Err2Signal is too strongChoose a surface with weaker reflectance. Use a reflecting plate if necessary.
Err3Low battery voltageCharge the battery.
Err4The working temperature is out of working rangeUse the device in the specified temperature range.
Err5Pythagorean measuring errorRe-measure and ensure that the hypotenuse is bigger than the cathetus (legs).
Err6Angle sensor errorDepot Repair

Specifications

ItemH-D510GH-D710GH-D100GH-D120G
Working Range0.05-50m (1.96in-164ft)0.05-70m (1.96in-229ft)0.05-100m (1.96in-328ft)0.05-120m (1.96in-394ft)
Distance measurement accuracy±(2mm+d*1/10000)
Inclination measurement range±90°
Angle accuracy±1°
Continuous measurement function√
Area volume measurement function√
Pythagorean measurement function√
Angle measurement and height measurement function√
Addition and subtraction measurement function√
Area volume addition and subtraction√
Min/Max√
Automatic calibration function√
Voice broadcastOnly Chinese voice broadcast
ScreenSegmented LCD 2.2-inch
Laser levelII
Laser type500-800nm, <1mW
Number of stored records99 times
Automatically cut off laser20 seconds
Automatic shut-down150 seconds
Full working time5,000 measurements per time
Storage temperature range-20°C~60°C
Range of working temperature0°C~40°C
Storage humidity20%~80% RH
Battery specifications3.7V 850mAh Lithium battery
Charging specificationsDC5V 0.8A Type-C
Charging timeAbout 1.5 hours
Dimensions118x54x25mm (4.5x2x1in)

Note: "d" indicates the actual distance. In harsh environments such as strong sunlight, fluctuating ambient temperature, weak reflection surfaces, or low battery power, measurement results may have large errors. In such cases, using a target reflector is recommended.

User Tips

  • For best accuracy, especially in challenging light conditions or over long distances, always use a reflecting plate.
  • Ensure the device is within its specified working temperature range (0°C-40°C) for optimal performance.
  • When performing Pythagorean measurements, double-check that the hypotenuse measurement is indeed longer than the legs to avoid error messages.
  • Keep the device charged, especially before important measurements, as low battery can affect accuracy.

Warranty and Support

For any technical support or warranty inquiries, please contact:

Sndway Technology (Guangdong) Co., LTD
Add: Sndway Science & Technology Industrial Park, 58 Tuanjie Road, Humen 523930, Dongguan, China
Service Hotline: 400-125-6969
Tel: 0769-85265688
E-mail: market@sndway.com

For detailed information, please refer to the full user manual (PDF) available from the seller.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.