1. Introduction
This manual provides detailed instructions for the proper use and maintenance of your Network Cable Tester, Model BS-468. This portable device is designed to quickly and efficiently test RJ45 and RJ11 network cables for various wiring faults, ensuring your network runs smoothly. It is an essential tool for network professionals and DIY enthusiasts alike.

2. Safety Information
- Read all instructions carefully before using the device.
- Do not expose the device to moisture or extreme temperatures.
- Use only the specified 9V battery. Incorrect battery types may damage the device.
- Keep out of reach of children.
- Do not attempt to disassemble or repair the device yourself. Refer to qualified personnel for service.
3. Package Contents
Verify that all items are present in the package:
- 1 x Master Unit (Cable Tester)
- 1 x Remote Unit
- 1 x User Manual (This document, also available as PDF: Download PDF)

4. Specifications
| Feature | Description |
|---|---|
| Model | BS-468 |
| Test Cable Types | RJ11, RJ45 (LAN UTP Ethernet) |
| Power Supply | DC 9V Battery (not included) |
| Power Consumption | 25mA |
| Dimensions (L x W x H) | 10.5 x 10.5 x 2.6 cm (4.13 x 4.13 x 1.02 inches) |
| Weight | 0.122 kg |
| Features | Stable performance, handheld and portable, detachable main unit/remote control |
5. Setup
5.1 Battery Installation
- Locate the battery compartment on the back of the Master Unit.
- Open the battery cover.
- Insert a new 9V battery, ensuring correct polarity (+/-).
- Close the battery cover securely.
Note: A 9V battery is not included with the product and must be purchased separately.
5.2 Connecting the Units
The Master Unit and Remote Unit can be used together or detached for testing longer cables.
- For short cables: Keep the Remote Unit attached to the Master Unit.
- For long cables or installed cables: Slide the Remote Unit off the Master Unit.

6. Operating Instructions
6.1 Basic Cable Testing
- Ensure a 9V battery is installed in the Master Unit.
- Connect one end of the network cable (RJ45 or RJ11) to the corresponding port on the Master Unit.
- Connect the other end of the cable to the corresponding port on the Remote Unit. If testing an installed cable, take the detached Remote Unit to the other end of the cable.
- Turn on the tester using the 'ON/OFF' switch located on the Master Unit.
- Observe the LED indicators on both the Master and Remote units. The LEDs will light up sequentially from 1 to 8 (and G for ground) to indicate the status of each wire pair.

6.2 Interpreting LED Indicators
- Normal Connection: LEDs 1-8 (and G) on both units light up in sequence, indicating a correct wiring order.
- Open Circuit: If an LED on the Master Unit lights up but the corresponding LED on the Remote Unit does not, it indicates an open circuit (broken wire) for that specific wire.
- Short Circuit: If two or more LEDs light up simultaneously on either unit, it indicates a short circuit between those wires.
- Cross-Pairs: If the sequence of LEDs on the Remote Unit does not match the sequence on the Master Unit, it indicates a cross-pair or incorrect wiring.
- No Lights: If no LEDs light up, check the battery, cable connections, or the cable itself might be severely damaged.
7. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the tester in a cool, dry place away from direct sunlight and moisture.
- Battery Replacement: If the LEDs become dim or the tester does not power on, replace the 9V battery. Remove the battery if the device will not be used for an extended period to prevent leakage.
- Handle with Care: Although portable, avoid dropping the device or subjecting it to strong impacts.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Tester does not power on. | Dead or incorrectly installed 9V battery. | Replace the 9V battery, ensuring correct polarity. |
| No LEDs light up. | Battery issue, faulty cable, or poor connection. | Check battery, ensure cables are fully inserted, try testing a known good cable. |
| Inconsistent LED sequence. | Cable has cross-pairs or split pairs. | Re-terminate the cable ends according to wiring standards (e.g., T568A/B). |
| Only some LEDs light up. | Open circuit (broken wire) in the cable. | Identify the broken wire by the unlit LED and repair or replace the cable. |
| Multiple LEDs light up at once. | Short circuit between wires. | Inspect cable for damage or re-terminate the connectors to eliminate shorts. |
9. User Tips
- Always carry a spare 9V battery, especially for on-site work, as the tester does not indicate low battery level directly.
- For quick checks, you can keep the remote unit attached. For testing long runs or installed wall jacks, detach the remote unit.
- Familiarize yourself with standard RJ45 (T568A and T568B) and RJ11 wiring diagrams to accurately interpret test results for cross-overs or split pairs.
- This tester is ideal for basic continuity and wiring map checks. For advanced network diagnostics (e.g., signal quality, packet loss), specialized equipment is required.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or refer to the product's original purchase documentation. Keep your proof of purchase for any warranty claims.
This manual is also available in PDF format for your convenience: Download User Manual (PDF).