Gaqqee 5918 lithium battery monitor

Contents

User Manual

Gaqqee 5918V Digital Battery Capacity Indicator

Model: 5918 lithium battery monitor

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Gaqqee 5918V Digital Battery Capacity Indicator. This versatile device is designed to monitor the voltage and capacity of various battery types, including ternary lithium, lithium iron phosphate, and lead-acid batteries, across a DC 7-100V range. Its precise monitoring, intelligent memory, and user-friendly interface make it ideal for electric vehicles, portable devices, and other applications requiring accurate battery status information.

2. Safety Information

  • This product has a closed design; unauthorized disassembly will damage it and void any potential support.
  • The input voltage must not exceed the product's operating range (DC 7-100V), otherwise, the product will be damaged.
  • The test data for this product is for reference only; please refer to professional instruments for actual conditions.
  • Ensure proper wiring: Red wire for positive (+), Black wire for negative (-). Incorrect wiring can cause damage.
  • Keep the device away from water, moisture, and extreme temperatures.
  • Do not attempt to repair the device yourself. Contact support if issues arise.

3. Product Overview

The Gaqqee 5918V Digital Battery Capacity Indicator features a wide viewing angle LCD color screen that displays battery percentage, voltage, and temperature (if applicable). It includes two control buttons: a power button (left) and a mode/pattern button (right).

Digital Voltmeter with Wide Viewing Angle LCD Color Screen

Figure 3.1: Digital Voltmeter with Wide Viewing Angle LCD Color Screen

The device is available in different mounting styles, including embedded and handlebar mount options.

Components for Embedded Mounting

Figure 3.2: Embedded Mounting Components

Components for Stand and Base Mounting

Figure 3.3: Stand and Base Mounting Components

4. Specifications

Parameter Value
Model Number 5918 lithium battery monitor
Voltage Measurement Range DC 7–100 V
Operating Current ≤20 mA
Detection Accuracy ±1%
Static Power Consumption <2 mA
Scanning Speed 1 scan/500 ms
Cable Length Approx. 45 cm (Red: Positive, Black: Negative)
Product Dimensions 59 × 59 × 18.2 mm
Cutout Dimensions (Hole Size) 54.56 mm
Display Type Digital Only
Operating Temperature 0-40 °C
Power Supply DC
Battery Included No
Data Record No
Table of Product Parameters for the 5918V Voltmeter

Figure 4.1: Product Parameters

Dimensional Diagram of the 5918V Voltmeter

Figure 4.2: Product Dimensions

5. Setup and Installation

Before installation, ensure the power source is disconnected to prevent electrical shock or damage to the device.

5.1 Wiring Instructions

  • Connect the Red wire to the positive (+) terminal of your battery or power source.
  • Connect the Black wire to the negative (-) terminal of your battery or power source.
  • Ensure connections are secure and insulated to prevent short circuits.

5.2 Mounting Options

The 5918V Voltmeter supports two primary mounting methods:

5.2.1 Embedded Installation
  1. Cut a circular hole with a diameter of approximately 54.56 mm in your desired mounting surface.
  2. Insert the voltmeter unit into the hole from the front.
  3. Secure the unit from the back using the provided bracket and nut.
DC 7-100V Digital Voltmeter and Battery Capacity Indicator (Embedded Style)

Figure 5.1: Embedded Installation Example

5.2.2 Handlebar Style Installation
  1. Attach the handlebar clamp to your handlebar using the provided screws.
  2. Mount the voltmeter unit onto the clamp, ensuring it is securely fastened and positioned for easy viewing.
DC 7-100V Digital Voltmeter and Battery Capacity Indicator with Handlebar Mount

Figure 5.2: Handlebar Installation Example

6. Operating Instructions

The device features two buttons: the Power button (left) and the Mode button (right).

6.1 Basic Operation

  • Power On/Off: On the home screen, long press the Power button for 2 seconds to turn the display on or off. Turning it off reduces power consumption.
  • Navigation: Short press the Mode button to cycle through different display modes or settings pages.
  • Enter/Exit Settings: On any settings page, long press the Mode button for 2 seconds to enter or exit the specific setting configuration.
  • Confirm Selection: Short press the Power button to confirm a selection or setting.

6.2 Mode Settings

Long press the Mode button on the home screen for 2 seconds to enter the settings page. Use short presses of the Mode button to navigate through the menus (Menu 1 to Menu 9).

6.2.1 Ternary Lithium Battery Settings (Menu 1: L-)
  1. Navigate to the L-03 page (default for ternary lithium 3-series).
  2. Long press the Mode button for 2 seconds until the '03' value flashes.
  3. Short press the Mode button to select the battery string number (L03 to L22 series).
  4. Short press the Power button to confirm the selected string number. The value will remain illuminated.
  5. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
Ternary Lithium Battery Settings Menu

Figure 6.1: Ternary Lithium Battery Settings (L-)

6.2.2 Lithium Iron Phosphate Battery Settings (Menu 2: F-)
  1. Navigate to the F-03 page (default for lithium iron phosphate 3-series).
  2. Long press the Mode button for 2 seconds until the '03' value flashes.
  3. Short press the Mode button to select the battery string count (F03 to F26 series).
  4. Short press the Power button to confirm the selected string number.
  5. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
Lithium Iron Phosphate Battery Settings Menu

Figure 6.2: Lithium Iron Phosphate Battery Settings (F-)

6.2.3 Acid Battery Settings (Menu 3: P-)
  1. Navigate to the P-12 page (default for 12V lead-acid battery).
  2. Long press the Mode button for 2 seconds until the '12V' value flashes.
  3. Short press the Mode button to select the battery voltage (12V, 24V, 36V, 48V, 60V, 72V, 84V).
  4. Short press the Power button to confirm the selected voltage.
  5. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
Acid Battery Settings Menu

Figure 6.3: Acid Battery Settings (P-)

6.2.4 Custom Voltage Settings (Menu 4: C-)

This menu allows setting custom low and high voltage thresholds.

  1. Navigate to the C- page.
  2. Long press the Mode button for 2 seconds to enter custom settings. The first digit on the left (low voltage) will flash.
  3. Short press the Mode button to adjust the flashing digit's value. Long press the Mode button for 2 seconds to shift to the next digit.
  4. After configuring three digits for the low voltage, short press the Power button to move to high voltage settings (right side).
  5. Repeat the process to set the high voltage thresholds.
  6. Short press the Power button to confirm. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
Menu Screens for Custom Voltage, Backlight, and Alarm Settings

Figure 6.4: Custom Voltage Settings (C-)

6.2.5 Backlight Settings (Menu 5: BL)

This menu allows adjusting the backlight duration.

  1. Navigate to the BL page.
  2. Long press the Mode button for 2 seconds until the '00' indicator flashes.
  3. Short press the Mode button to cycle through options: '00' (normally lit), '10' (10 seconds), '20' (20 seconds), ..., '90' (90 seconds).
  4. Short press the Power button to confirm the selection.
  5. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
6.2.6 High/Low Voltage Alarm Settings (Menu 6: AL)

This menu allows setting the thresholds for low and high voltage alarms.

  1. Navigate to the AL page.
  2. Long press the Mode button for 2 seconds to enter alarm settings. The first digit on the left (low voltage alarm) will flash.
  3. Short press the Mode button to adjust the flashing digit's value. Long press the Mode button for 2 seconds to shift to the next digit.
  4. After configuring three digits for the low voltage alarm, short press the Power button to move to high voltage alarm settings (right side).
  5. Repeat the process to set the high voltage alarm thresholds.
  6. Short press the Power button to confirm. Long press the Power button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
6.2.7 Electronic Calibration Function (Menu 7: CL)

This function allows for voltage electronic calibration. Note: This function should ideally be performed by professionals. The calibrated voltmeter must be connected to a 30V power supply during calibration.

  1. Navigate to the CL page.
  2. Long press the Mode button for 2 seconds. The CL indicator will flash.
  3. Once automatic calibration is complete, the CL indicator will remain lit, and the system will automatically return to the normal page.
Menu Screens for Voltage Calibration, SOC Mode, and Factory Reset

Figure 6.5: Voltage Calibration Settings (CL)

6.2.8 SOC Mode Settings (Menu 8: SO)

This function relates to State of Charge (SOC) mode. Please contact the manufacturer for detailed instructions on using this function.

  1. Navigate to the SO page.
  2. Long press the Mode button for 2 seconds.
  3. Select ON or OFF on the right side.
  4. Short press the Power button to confirm.
  5. Long press the Mode button for 2 seconds to return to the home screen, or short press the Mode button to proceed to the next settings page.
6.2.9 Factory Reset (Menu 9: rF)

Warning: Non-professionals should not use this function, as it may affect product performance.

  1. Navigate to the rF page.
  2. Long press the Mode button for 2 seconds until the three '8's on the right start flashing and turn into three '0's.
  3. After restoring factory settings, the three '0's will remain lit, indicating the process is complete. The device will then automatically return to the normal page.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods.
  • Inspection: Periodically check the wiring for any signs of wear or damage. Ensure all connections are secure.

8. Troubleshooting

Problem Possible Cause Solution
Display does not turn on No power, incorrect wiring, or device off. Check power connections. Ensure red wire is to positive, black to negative. Long press the Power button to turn on.
Incorrect voltage/capacity readings Wrong battery type setting, uncalibrated. Verify and adjust the battery type settings (Menu 1, 2, or 3). Consider electronic calibration (Menu 7) if readings are consistently off.
Low voltage warning (lightning symbol) Battery level below 10% (factory default) or custom low voltage alarm triggered. Charge your battery. Check your low voltage alarm settings (Menu 6) if the warning seems premature.
Settings not saving after power off This device has a power-off memory function. If settings are not retained, there might be an internal issue. Ensure you are confirming settings with a short press of the Power button. If the issue persists, perform a factory reset (Menu 9) and reconfigure. If still problematic, contact support.

9. User Tips

  • Verify Battery Type: Always ensure the correct battery type (Ternary Lithium, Lithium Iron Phosphate, or Acid Battery) and string count/voltage are set in the respective menus for accurate readings.
  • Utilize Alarms: Configure the high/low voltage alarms (Menu 6) to receive timely warnings, helping to prevent over-discharge or over-charge of your battery.
  • Backlight Management: Adjust the backlight duration (Menu 5) to save power, especially in applications where continuous illumination is not required.
  • Regular Checks: Periodically check the displayed voltage and capacity against your battery's known state to ensure the monitor is functioning optimally.

10. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the seller directly. A user manual in PDF format is available for download, which may contain additional information.

You can access the user manual (PDF) here.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.