1. Introduction
The JIKONG Smart BMS V19 is an intelligent protection board designed for high-capacity series lithium battery packs. It offers comprehensive management features including voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functionality. This BMS is compatible with LiFePo4, Li-ion, and LTO battery types.
The protection board utilizes energy transfer active balancing technology, ensuring maximum continuous balancing currents of 1A/2A. This technology significantly improves battery consistency, extends battery life, and delays battery aging.
A dedicated mobile APP (available for Android and iOS) connects via Bluetooth, allowing users to monitor battery status, modify parameters, and control charge/discharge switches. Its compact size and full functionality make it suitable for various applications such as small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Key Features
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Information screen display support
- Accurate time logging
- Optional RS485 support
- Optional CAN support
- Optional ACC detection function
- Optional heating function
- Parallel function support
- Optional alarm function
- Concatenation function support
- GPS communication support
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
3. Package Contents
The JIKONG Smart BMS V19 package includes all necessary accessories for easy installation.


4. Setup and Installation
4.1. APP Installation
To manage and monitor your JIKONG Smart BMS, you need to install the dedicated mobile application. The Android APP requires Android Version 7 minimum.

4.2. Device Activation
Before powering on the protection board, ensure all balance cables are correctly connected, and the P- and B- terminals are properly wired. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a power-on control switch. It is designed for charging activation: the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the BMS.
Alternatively, the BMS can be activated via a key switch or the display screen. If you have the optional display screen and button, simply connect the cable to the display interface and press the button to activate.
4.3. Wiring Diagram and Installation Method
The JK-BxA8S-20PS series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Refer to the diagram below for detailed connections.

Connector and LED Definitions:
| Coupler | Type of Connector | Interface Name | Pin Number | Pin Name | Definition |
|---|---|---|---|---|---|
| P1 | XH-10AW-2.54 | Balance with Acquisition interface | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positives | |||
| 3 | B2 | The second battery positive | |||
| 4 | B3 | The third battery positive | |||
| 5 | B4 | The fourth battery positive | |||
| 6 | B5 | The fifth battery positive | |||
| 7 | B6 | The sixth battery positive | |||
| 8 | B7 | The seventh battery positive | |||
| 9 | B8 | The eighth battery positive | |||
| 10 | B+ | Protection board power supply, connected to the battery | |||
| P2 (Optional) | A1254WF-2A | Buzzer interface | 1 | GND | Buzzer power negative |
| 2 | VCC | Buzzer power supply positive | |||
| P3 (Optional) | A1254WF-4A | Communication interface | 1 | CAN_L | CAN signal negative terminal |
| 2 | CAN_H | CAN signal positive terminal | |||
| 3 | RS485_A | RS485 signal positive terminal | |||
| 4 | RS485_B | RS485 signal negative terminal | |||
| P4 | 1.25T-4PWT | UART interface | 1 | GND | Power/signal ground |
| P5 | HY2.0-4P | 4 external optional Temperature interface | 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B | |||
| 3 | T4A | Fourth temperature sensor pin A | |||
| 4 | T4B | Fourth temperature sensor pin B | |||
| P6 | HY2.0-4P | Temperature interface | 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B | |||
| 3 | T2A | Second temperature sensor pin A | |||
| 4 | T2B | Second temperature sensor pin B | |||
| P7 | A1254WF-6A | Display interface | 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activate the positive signal | |||
| 3 | GND | Power negative (Negative terminal) | |||
| 4 | B | Display RS485 signal negative | |||
| 5 | A | Display RS485 signal positive | |||
| 6 | VCC | Display power output | |||
| P8 | A1254WF-3A | Parallel interface | 1 | P-status | Parallel module status signal |
| Heating Wire | 16AWG-Orange-15CM (Optional) | Heating element negative electrode | 1 | HT- | Heater element negative electrode |
| D1 | Bluetooth connection indicator | Steady on when connected, blinking when disconnected. | |||
| P- | Connect to external load or negative terminal of charger, equipped with M6 screws. | ||||
| B- | Connect to the negative battery terminal, equipped with M6 screws. |
5. Operating Instructions
5.1. Active Equalization
The BMS uses active equalization to transfer energy from higher voltage cells to lower voltage cells, minimizing energy loss. Before using this function, set the basic battery parameters in the APP, including cell count, battery capacity, trigger equalization differential pressure (default is acceptable), voltage calibration, and current calibration. The default balance current is 1A/2A, adjustable based on battery capacity. If not needed, disable the balancing switch in the APP's BMS control page.

5.2. UART and Display Interface
The BMS includes a UART interface for optional GPS integration, allowing for battery location tracking. A display interface is also provided for connecting JIKONG's display screen, offering convenient access to battery information.

5.3. Heating Function (Optional)
For low-temperature conditions, the optional heating function uses a resistance heater or heating film to warm the battery, preventing reduced activity and ensuring proper charging/discharging. The designed heating current is 20A. Users can enable/disable this function via the APP's BMS control page based on ambient temperature. It is recommended to use a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary protection.
5.4. Alarm Function (Optional)
The BMS supports an optional alarm function. It will alert users when it detects safety risks such as over-temperature, overcharge, or over-discharge.
5.5. Battery Parallel Function
The BMS supports battery pack parallel functionality for energy storage applications. This requires a parallel module and disabling the "disable charging current limiting" function in the APP.
5.6. ACC Detection Function (Optional)
The optional ACC detection function enables discharge. This can be achieved by applying a voltage between ACC+ and ACC- (20V-100V) or by directly short-circuiting ACC+ and ACC-. Additionally, dedicated C_detect+ and C_detect- interfaces are provided for charger detection (12V signal) to enable charging.
5.7. Protection Features
- Charge Overvoltage Protection & Recovery: Standard feature. Users can set individual cell overcharge protection and recovery voltages via the APP. If any cell exceeds the set overvoltage during charging, the BMS will stop charging. Charging resumes when all cells drop below the recovery voltage.
- Discharge Undervoltage Protection & Recovery: Standard feature. Users can set battery undervoltage protection, recovery, and automatic shutdown voltages via the APP. If any cell drops below the undervoltage protection during discharge, the BMS will stop discharging. Discharge resumes when all cells are charged above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down.
- Charge Overcurrent Protection & Recovery: Standard feature. Users can set continuous charging current, overcurrent delay, and recovery time via the APP. If charging current exceeds the set limit for the specified delay, charging stops. Charging resumes after the recovery time.
- Discharge Overcurrent Protection & Recovery: Standard feature. Users can set continuous discharge current, overcurrent delay, and recovery time via the APP. If discharge current exceeds the set limit for the specified delay, discharging stops. Discharging resumes after the recovery time. (Note: Max continuous discharge current cannot exceed 200A).
- Over-temperature Protection & Recovery: Standard feature for charge and discharge. Users can set charge/discharge over-temperature protection and recovery values via the APP. If the BMS detects temperatures above the set limit, it will stop the respective operation. Operation resumes when temperatures fall below the recovery value.
- Low-temperature Protection & Recovery: Standard feature for charging. Users can set charge low-temperature protection and recovery values via the APP. If the BMS detects temperatures below the set limit, it will stop charging. Charging resumes when temperatures rise above the recovery value. Heating function is recommended for extremely cold regions.
- Short Circuit Protection & Recovery: Standard feature. The current to trigger short circuit protection is not user-settable. Users can set the short circuit protection delay (µs) and recovery time (S) via the APP. If a short circuit occurs, the BMS will stop operation and resume after the recovery time. Adjusting the delay can help prevent false triggers due to high instantaneous currents from chargers or loads.
5.8. Emergency Switch
The BMS includes a standard emergency switch function. If issues like over-temperature, over-discharge, over-charge, or cell string drops occur during normal use, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes. This provides an emergency operational window. Even if a cell reaches automatic shutdown voltage during this period, the BMS will continue to operate until the 30-minute cycle ends, preventing dangerous situations.
5.9. Intelligent Sleep
The BMS features a standard intelligent sleep function, which can be enabled or disabled via the APP. Its purpose is to reduce the BMS's energy consumption from the battery when in standby (charging/discharging current less than 1A for 26 consecutive hours). To reactivate the BMS, use the button or connect a charger.
5.10. Communication Function
The BMS supports optional CAN and RS485 communication. Users can select these options and configure the multiplexed ports via the APP. Address and communication protocol settings can be adjusted based on requirements. Refer to the JIKONG Protection Board communication protocol document for details.

6. Specifications
6.1. Product Appearance and Dimensions
The JIKONG JK-BxA8S-20PS series protection board has dimensions of $152.25mm imes 127.26mm imes 15.6mm$.


6.2. Main Parameters
| Item | Parameter | Unit |
|---|---|---|
| Supply voltage | 7.5-36 | V |
| Series withstand voltage | 100 | V |
| Operating power consumption | <1300 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 8 | String |
| Maximum balancing current | 1A / 2A | A |
| Maximum charging current | 200 | A |
| Maximum discharge current | 200 | A |
| Maximum instantaneous current | 400 | A |
| Maximum internal loop resistance | 0.35 | mΩ |
| Protective plate size | 152.25*127.26*15.6 | mm |
| Finished weight | 424 | g |
| Support maximum series battery pack | 12V (6 pack) / 24V (3 pack) |
6.3. Default Parameters
The following table outlines the default parameters for different battery types. These can be adjusted via the APP.
| Parameter | Li-ion (Ternary) | LiFePo4 | LTO (Lithium Titanate) | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 1A / 2A | 1A / 2A | 1A / 2A | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Single overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charge overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | µs |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charge overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charge low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
7. User Tips
- Parallel Setup: The JIKONG Smart BMS is confirmed to work well in 24V parallel setups, providing reliable performance.
- Quality Assurance: Users consistently report good product quality and construction.
- Packaging: The product is typically well-packaged, ensuring safe delivery.
8. Troubleshooting
8.1. Inaccurate Voltage Readings
- Measure the actual total voltage of the battery pack with a multimeter.
- Enter this actual total voltage into the "voltage calibration" setting on the APP's parameter setting page.
8.2. Inaccurate Current Readings
- Ensure that both the B- and P- terminals of the protection board are connected with two 7AWG wires in parallel. Failure to do so may lead to current errors.
- Measure the actual current of the battery pack with a clamp meter.
- Enter this actual current into the "current calibration" setting on the APP's parameter setting page. Higher actual currents lead to higher calibration accuracy.
8.3. Inaccurate Capacity Readings
- The initial capacity estimated when the protection board is first powered on is often inaccurate.
- For accurate calibration, fully discharge the battery pack to its cut-off voltage, then fully charge it without interruption. The capacity will be calibrated during this process.
8.4. Inconsistent String Number
- Verify that the "unit quantity" in the APP's parameter settings is correctly configured to match your battery pack's string count.
- If there is no voltage reading for two or more strings in the middle of the pack, check if the acquisition cable has become disconnected.
9. Warranty and Support
The JIKONG Smart BMS V19 comes with a 12-Month Warranty and professional support. For any technical assistance or warranty claims, please contact JIKONG customer service.