1. Introduction
The Gaqqee GY-6ST is a versatile LCD battery level indicator designed to monitor the charge and voltage of various battery types. It offers four selectable display modes and allows for custom parameter settings, including battery percentage and alarm thresholds. This device is suitable for a wide range of applications, including electric vehicle battery packs, outdoor emergency equipment, medical equipment, and general measuring equipment.
The GY-6ST is available in two main versions: V6 and V4, each supporting different voltage ranges:
- GY-6ST V6: Operates within a 9-120V range, designed with high-power components for impact and pressure resistance. Recommended for batteries above 12V.
- GY-6ST V4: Suitable for a 5-73V range, ideal for batteries between 5-12V.
The clear LCD screen and low-power design ensure convenient and efficient battery monitoring.
2. Safety Information
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Always ensure proper handling and installation of electrical components. Disconnect power before making any connections or adjustments. Do not expose the device to extreme temperatures or moisture. Use only with compatible battery types and voltage ranges as specified.
3. Package Contents
The package typically includes:
- 1 x Gaqqee GY-6ST Battery Level Indicator
- 1 x Wiring Harness
Note: For detailed instructions and further documentation, please refer to the official user manual PDF available from the seller.
4. Specifications
| Feature | Specification |
|---|---|
| Brand Name | Gaqqee |
| Model Number | GY-6ST (12 volt battery charge gauge) |
| DIY Supplies | Electrical |
| Certification | CE |
| Origin | Mainland China |
| Power Supply / Source | DC |
| Accuracy Class | 0.01 |
| Dimensions (Product) | 61.3 x 33.3 x 13.8 mm |
| Cut-out Size | 58.5 x 28.5 mm |
| Weight | 21.4 g |
| Operating Temperature | 0-40 ℃ (General), -20 to 50 ℃ (Performance) |
| Battery Included | No |
| Data Record | No |
| High-concerned chemical | None |
Performance Parameters (GY-6ST V6 / V4)
| Parameter | V6 Version (Min-Max) | V4 Version (Min-Max) |
|---|---|---|
| Operating Voltage (V) | 9 - 120 | 5 - 73 |
| Operating Current (mA) | 3 - 5 | 3 - 5 |
| Sleep Current (uA) | 8 - 30 | 8 - 30 |
| Voltage Accuracy | 0.5% - 1% | 0.5% - 1% |
| Power Resolution | 1 | 1 |
Scope of Use (Battery Types)
| Battery Type | GY-6ST V6 Application Range | GY-6ST V4 Application Range |
|---|---|---|
| Lead-acid battery | 12V, 24V, 36V, 48V, 60V, 72V, 84V | 12V, 24V, 36V, 48V |
| Lithium Battery | 3-28 strings | 2-17 strings |
| Lithium Iron Phosphate Battery | 4-28 cells | 3-17 cells |
| Customizable Voltage Range | 9V-120V | 5V-73V |
5. Setup
5.1. Wiring Method
Connect the battery monitor according to the diagram below. Ensure correct polarity: the red wire connects to the positive terminal of the battery, and the black wire connects to the negative terminal.
The GY-6STV6 version uses a yellow socket for wiring, while the GY-6ST V4 version uses a white socket.
5.2. Entering and Exiting the Settings Interface
To enter the settings interface:
- High Efficiency Method: Press and hold the 'Set' button without releasing while powering on the device.
- Standard Method: Press and hold the 'Set' button for more than 5 seconds (can be done without powering off).
To exit the settings interface:
- Disconnect the power cable.
- If no button is pressed for 20 seconds, the device will automatically exit the settings.
5.3. H-1 Battery Specifications and Series Configuration
Once in the settings interface, press the 'Function' key to navigate to the H-1 setting. Here you can configure the battery type and series. Examples of codes include:
- Lithium Battery: L20 (for 20-string lithium battery)
- Lead-acid Battery: P04 (for 48V lead-acid battery)
- Lithium Iron Phosphate Battery: F16 (for 16-string lithium iron phosphate battery)
6. Operating Instructions
6.1. Key Description
The device features two main keys for operation:
- Long Press (more than 2 seconds): Activates specific functions or enters settings.
- Press and Hold (more than 5 seconds): Used for specific setup procedures, such as entering settings without powering off.
6.2. Display Modes
The GY-6ST offers four distinct display modes:
- Battery Percentage + Voltage Value: Displays both battery percentage and voltage. Can be manually switched between these values using the 'Function' key.
- Battery Percentage Only: Displays only the battery percentage.
- Voltage Value Only: Displays only the voltage value.
- Alternating Display: Automatically alternates between battery percentage and voltage value every 3 seconds.
6.3. Function Settings (H-Settings)
The device features several configurable settings, accessed via the settings interface:
- H-1: Battery Specifications and Series Configuration: Displays the power usage value based on the default parameter.
- H-2: Custom Percentage Lower Limit Setting: Sets a custom lower limit for battery percentage.
- H-3: Custom Percentage Upper Limit Setting: Sets a custom upper limit for battery percentage.
- H-4: Automatic Delayed Shutdown Function: Configures the automatic shutdown delay.
- H-5: Display Mode Settings: Allows selection of the desired display mode.
- H-6: Customizable Lower Alarm Limit Settings: Sets the lower limit for the alarm function.
- H-7: Custom Alarm Threshold Setting: Sets the maximum parameter value for the alarm function.
Note: When powered on, the device first displays the battery settings for easy viewing. If H-1 is selected, custom functions H-2 and H-3 are disabled. If a custom function (H-2 or H-3) is selected, H-1 is turned off.
6.4. H-2 Custom Percentage Lower Limit Setting
To set the lower percentage limit:
- Enter the settings interface and navigate to H-2 using the 'Set' button.
- Press the 'Function' button to enter the settings for H-2.
- Use the 'Set' key to shift the decimal point and the 'Function' key to adjust the value.
- After setting, press and hold the 'Set' button to exit H-2 settings.
Note: If the lower limit value is set to be greater than or equal to the upper limit value (H-3), the second bar on the display will flash as a warning. If this condition is not met, the default settings will be used.
6.5. H-3 Custom Percentage Upper Limit Setting
To set the upper percentage limit:
- Enter the settings interface and navigate to H-3 using the 'Set' button.
- Press the 'Function' button to enter the settings for H-3.
- Use the 'Set' key to shift the decimal point and the 'Function' key to adjust the value.
- After setting, press and hold the 'Set' button to exit H-3 settings.
Note: If the upper limit value is set to be less than or equal to the lower limit value (H-2), the third bar on the display will flash as a reminder. If this condition is not met, the default settings will be used.
6.6. H-4 Automatic Delay Function Activation/Deactivation
To configure the automatic delayed shutdown:
- Enter the settings interface and navigate to H-4 using the 'Set' button.
- Press the 'Function' button to enter the settings for H-4.
- Press and hold the 'Function' button again to toggle the delayed shutdown function on or off.
6.7. H-5 Display Mode Settings
To select the display mode:
- Enter the settings interface and navigate to H-5 using the 'Set' button.
- Press the 'Function' button to cycle through the available display modes.
- After selecting the desired mode, press and hold the 'Set' button to exit H-5 settings.
Note: The third display mode (voltage only) is indicated by a 'V' icon. The fifth display mode (manual switching between voltage and percentage) is indicated by a battery symbol with a grid.
6.8. H-6 Customizable Lower Alarm Limit Settings and Activation/Deactivation
To set the lower alarm limit:
- Enter the settings interface and navigate to H-6 using the 'Set' button.
- Press the 'Function' button to enter the settings for H-6.
- Use the 'Set' button to select whether the alarm is based on 'V' (voltage) or '%' (percentage).
Note: Versions with a buzzer will provide both sound and light alarms. Versions without a buzzer will use flashing lights for alarms.
6.9. H-7 Custom Alarm Threshold Setting and Activation/Deactivation
To set the alarm threshold:
- Enter the settings interface and navigate to H-7 using the 'Set' button (refer to H-6 for setting steps).
- Press the 'Function' button to enter the settings for H-7.
- Use the 'Set' button to select whether the alarm threshold is based on 'V' (voltage value) or '%' (percentage).
Note: The upper limit alarm mode is synchronized with the lower limit value. For example, if the lower limit is set to a voltage-based alarm, the upper limit alarm will also be voltage-based.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
- Inspection: Periodically check the wiring for any signs of damage or loose connections.
8. Troubleshooting
- Display shows 0% and 100% after powering on: This indicates that the setting parameters may not match the battery being measured. Please enter the settings interface (H-1) and verify that the battery type and series configuration are correct.
- No display after powering on: Check the wiring connections. Ensure the positive and negative wires are connected correctly to the battery. Also, verify that the battery voltage is not too low for the device to power on.
- Incorrect readings: Ensure the correct battery type and parameters are selected in the H-1 settings. Check for stable power supply.
- Alarm not functioning as expected: Verify the H-6 and H-7 alarm settings, including whether it's set for voltage or percentage, and the threshold values.
9. User Tips
- Verify Settings: Always double-check your battery type and custom settings (H-1, H-2, H-3) after initial setup or if you notice unusual readings.
- Choose the Right Version: If you work with a wide range of battery voltages, the GY-6ST V6 (9-120V) offers greater flexibility. For lower voltage systems, the V4 (5-73V) might be sufficient.
- Utilize Alternating Display: For quick monitoring of both percentage and voltage, consider using the alternating display mode (Mode 4) to get a comprehensive overview without manual switching.
- Alarm Customization: Take advantage of the customizable alarm limits (H-6, H-7) to set alerts specific to your battery's safe operating parameters.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
You can also refer to the comprehensive user manual PDF for more detailed information: Gaqqee GY-6ST User Manual (PDF)