GOYOJO AMF Digital Force Gauge

Contents

GOYOJO Digital Force Gauge User Manual

Model: AMF Digital Force Gauge

1. Overview

The Digital Force Gauge with a digital display is a small, versatile, and highly accurate push-pull test instrument. It is widely used in various industries such as electronics, construction hardware, textiles, automotive parts, fire equipment, and scientific research institutions. This new generation instrument offers high resolution, fast sampling speed, and user-friendly operation.

2. Features

  • High precision and resolution for accurate measurements.
  • Three measurement modes to choose from: Real-time, Peak, and First peak.
  • Selectable units for measurement: N (Newton), Kg (Kilogram), Lb (Pound), and Oz (Ounce).
  • Gravity acceleration setting allows precise unit conversion based on your location.
  • Upper and lower limits can be set for statistical analysis, with a buzzer alarm for limit exceedance.
  • Minimum force value shielding function to exclude data within a set minimum range.
  • Automatic shutdown function, configurable for power saving when the device is not in use.
  • Powered by 2 AAA batteries (1.5V*2) for convenience.
  • Automatic backlight and buzzer alarm function.

3. Specifications

Technical Specifications
AttributeValue
Model NumberDigital Push-Pull Force Gauge
Brand NameGOYOJO
Display TypeDIGITAL
OriginMainland China
Battery IncludedNo
High-concerned chemicalNone
Accuracy±1% (10%~100% of full scale)
Power2 AAA batteries 1.5V
Working temperature5°C~35°C
Transport temperature-10°C~60°C
Relative humidity15%~80%RH
Working conditionsNo vibration source around and no corrosive environment.
Dimensions124*60*31(mm)
Net weight0.4Kg

Maximum Load Values and Load Division Values:

Model2N3N5N10N20N30N50N100N200N300N500N
Maximum load value (kg)0.2kg0.3kg0.5kg1kg2kg3kg5kg10kg20kg30kg50kg
Maximum load value (Lb)0.45Lb0.65Lb1.1Lb2.2Lb4.5Lb6.5Lb11Lb22Lb45Lb65Lb110Lb
Load division value (N)0.001N0.01N0.1N
Load division value (kg)0.001kg0.001kg0.01kg
Load division value (Lb)0.001Lb0.001Lb0.01Lb

4. Product Structure and Components

The diagram below illustrates the main components of the Digital Force Gauge:

Diagram showing the front and back structure of the Digital Force Gauge with labels for Connection connector, LCD Monitor, Buzzer, SET button, ZERO button, PEAK button, UNIT button, Power Button, and Battery compartment.
Figure 1: Product Structure Diagram
  • Connection connector: Point for attaching various test fixtures.
  • LCD Monitor: Displays measurement values, mode, unit, and battery level.
  • Buzzer: Provides audible alerts for limit exceedance and other functions.
  • SET button: Used to enter and confirm system settings.
  • ZERO button: Resets the measured value to zero.
  • PEAK button: Switches between measurement modes (Real-time, Peak, First Peak) and adjusts values in settings.
  • UNIT button: Selects the desired measurement unit and scrolls through settings.
  • Power Button: Turns the instrument on and off.
  • Battery compartment: Houses the 2 AAA batteries.

5. Display

The instrument's LCD monitor provides crucial information during operation:

Diagram of the Digital Force Gauge display showing battery level, mode indicators (AUTO, P, T, MEM), units (K, N, kg, lb, Oz), measured value, and tension/compression arrows.
Figure 2: LCD Display Elements
  1. Battery level: Indicates the remaining battery power.
  2. Mode display:
    • When the screen simultaneously shows the letters "P" and "T," it indicates the First Peak mode. In this mode, the screen displays the first peak measured within a certain time period.
    • When the screen displays the letter "P" alone, it represents the Peak mode. In this mode, the screen records and displays the maximum measured force value.
    • When neither the letters "T" nor "P" appear on the screen, it indicates Real-time mode. In this mode, the screen shows the applied force value in real-time.

    Press the "PEAK" button to freely switch between First Peak mode, Real-time mode, and Peak mode.

  3. Unit display: Shows the currently selected measurement unit (N, kg, Lb, Oz).
  4. Display of measured force value: The numerical reading of the force.
  5. Tension and Compression indicators: An upward arrow represents tension, and a downward arrow represents compression.

6. Setup

Battery Installation

The device is powered by 2 AAA batteries (1.5V*2). To install or replace batteries:

  1. Open the battery compartment cover located on the back of the device.
  2. Insert two AAA batteries, ensuring correct polarity (+/-).
  3. Close the battery compartment cover securely.

Attaching Test Fixtures

The Digital Force Gauge comes with various probes and an extended rod for different measurement needs. To attach a fixture:

Digital Force Gauge with various probes and an extended rod laid out next to it.
Figure 3: Digital Force Gauge with included accessories
  1. Select the appropriate test joint fixture for your measurement purpose (e.g., hook, flat probe, pointed probe, extended rod).
  2. Gently screw the chosen adapter onto the connection connector at the top of the force gauge. Do not overtighten, as this may damage the sensor.
  3. Ensure the fixture is securely attached before beginning any test.

7. Operating Instructions

A. Power On/Off

  1. Press the Power Button to turn on the instrument.
  2. The boot display will show a specification model (e.g., "100N") briefly, then switch to the test interface (e.g., "0.0").
  3. To turn off, press and hold the Power Button again.

B. Unit Switching

Press the UNIT button to cycle through the available measurement units: N (Newton), kg (Kilogram), Lb (Pound), and Oz (Ounce).

C. Zero Value Reset

Press the ZERO button to reset the measured value on the screen to 0.0. This should be done before each new measurement to ensure accuracy.

D. Measurement Mode Selection

Press the PEAK button to choose the desired measurement mode:

  • Real-Time Mode: Upon turning on, the system defaults to real-time measurement. The displayed value dynamically changes as the load varies.
  • Peak Mode: Press the PEAK key until "P" is displayed. The screen shows the maximum measured force value. During subsequent measurements, if a new value is lower than the previous maximum, the display remains unchanged; if higher, the display updates.
  • First Peak Mode: Press the PEAK key until "P" and "T" are displayed. The instrument shows only the first peak value measured within a specific time frame. Subsequent measurements are not displayed. To re-measure, press ZERO to clear the display.

8. System Settings

To access and modify system settings:

  1. Press the SET button to enter the system settings interface.
  2. Use the PEAK button to scroll down or the UNIT button to scroll up and select a setting item.
  3. Press the SET button to confirm the selection or ZERO to exit without saving.

A. Setting the Upper Limit of Measurement Value

  1. From the system settings, select "Hide" (Upper Limit). Press SET.
  2. Use UNIT to select the counting unit.
  3. Use PEAK to set the desired value.
  4. Press SET to save.

Note: The upper limit is set to full range by default. Exceeding it will trigger a "MAX" display and continuous buzzer alarm.

B. Setting the Lower Limit of Measurement Value

  1. From the system settings, select "Lodt" (Lower Limit). Press SET.
  2. Use UNIT to select the counting unit.
  3. Use PEAK to set the desired value.
  4. Press SET to save.

Note: The lower limit is set to 0 by default. Falling below it will trigger a "MIN" display and continuous buzzer alarm.

C. Setting the Minimum Peak Value for Storage

  1. From the system settings, select "LoSt" (Minimum Peak Value). Press SET.
  2. Use UNIT to select the counting unit.
  3. Use PEAK to set the desired value.
  4. Press SET to save.

Note: In peak mode, if the measured value is below this set minimum, it will not be saved or displayed.

D. Setting the Gravity Acceleration

  1. From the system settings, select "95EL" (Gravity Acceleration). Press SET.
  2. Use UNIT to select the counting unit.
  3. Use PEAK to set the desired value.
  4. Press SET to save.

Note: Users can set the gravity acceleration value based on their geographical location. The default value is 9.800.

E. Setting the Auto Shutdown Time

  1. From the system settings, select "oFFt" (Auto Shutdown Time). Press SET.
  2. Use UNIT to decrease or PEAK to increase the power-off time value.
  3. Press SET to save.

Note: Users can set the power-off time from 0 to 15 minutes. The default is 10 minutes.

F. Setting the Backlight Function

  1. From the system settings, select "LED" (Backlight). Press SET.
  2. Use UNIT to select the backlight status: "Auto" (turns on with operation, off when idle), "OPEn" (always-on), or "CLOS" (always-off).
  3. Press SET to save.

G. Setting the Display Direction of Thrust and Tension Arrows

  1. From the system settings, select "dir" (Direction). Press SET.
  2. Use UNIT to select the direction: "YES" (upward arrow for tension, downward for thrust) or "no" (upward arrow for thrust, downward for tension).
  3. Press SET to save.

H. Setting to Mask Data Below 0.5% of Full Scale

  1. From the system settings, select "SHid" (Mask Data). Press SET.
  2. Use UNIT to select "YES" for masking or "no" for not masking.
  3. Press SET to save.

I. Restore Factory Settings

  1. From the system settings, select "rSEt" (Restore Factory Settings). Press SET.

Note: After restoring factory settings, the device will automatically shut down. Press the power button to continue using the device.

9. Testing Procedure

You can perform tests using the factory default settings or by configuring the test mode as required.

A. Select the Appropriate Test Joint Fixture

Install the appropriate test joint fixture onto the push-pull force gauge as described in the Setup section.

B. Proper Testing Procedure

Hold the push-pull force gauge firmly or install it on a suitable testing machine. During the test, align the tested force with the push-pull rod of the force gauge to measure accurate load values.

Diagram illustrating correct and incorrect ways to apply force during testing. Correct measurement shows force aligned with the rod, while incorrect measurements show angled force.
Figure 4: Correct vs. Incorrect Measurement Application

C. After the Test

After completing the test, unload the load, turn off the power, remove the fixture, and store the objects back into the tool box for future use.

10. Safety Precautions

  • Incorrect operation may damage the instrument or cause serious accidents. Please read this manual carefully before use and keep it for future reference.
  • For testing impact loads, select a model with a maximum load twice the expected impact load.
  • Wear protective masks and gloves during destructive testing to prevent injury from splashing materials.
  • Avoid using damaged or severely bent fixtures. Various fixtures are available for purchase according to needs.
  • Do not exceed the maximum range of the instrument to avoid damaging the sensor or causing accidents.
  • The buzzer will beep continuously if the test value exceeds 100% of full scale. Quickly release the load or reduce it to avoid potential damage. Exceeding 120% of full scale may damage the instrument.

11. Maintenance and Storage

  • Use the matching battery with correct parameters to avoid circuit failure or fire.
  • Do not touch the power battery with wet hands to prevent damage to the battery.
  • Clean the machine with a soft cloth soaked in detergent. Avoid using volatile chemicals (e.g., volatile agents, thinner, alcohol) for cleaning.
  • Do not operate the machine in humid, dusty, oily, or chemically-exposed environments with vibrating sources nearby.
  • Use and store the instrument within the specified temperature and humidity range to prevent instrument failure.
  • Do not dismantle, repair, or modify the machine yourself, as it may lead to permanent instrument failure.
  • Observe other safety measures related to production.
  • If the instrument crashes unexpectedly, open the battery cover, remove the battery, reinstall it, and restart the instrument.

12. Troubleshooting

ProjectSymptomCause or PhenomenonSolution
Power SupplyPress the "power" button, no displayNo batteryReplacement battery
Test ValueTest value is not accurateThe error is too largeUser calibration
OtherUnexpected crashNo response when pressing any keyReinstall the battery

13. User Tips

This section typically provides helpful advice and common solutions based on user feedback and frequently asked questions. As no specific user reviews or Q&A data were provided for this product, general tips are not available at this time.

14. Warranty and Support

The warranty period for this product is 1 year from the date of purchase.

For repair or maintenance inquiries, please contact customer support:

  • Email: SIGN2@GOYOJO.COM
  • Phone/WhatsApp: +86 19924549574
  • Address: YUNZHI TECHNOLOGY PARK, GUANGMING DISTRICT, SHENZHEN

For a detailed user manual in PDF format, you may refer to the official document: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.