1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your Gaqqee BT210 Dual-Channel 18650 Lithium-Ion Battery Capacity Tester. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.
2. Safety Information
- Use only compatible 18650 lithium-ion batteries charged to 4.2V.
- Ensure the power supply is DC 5V/2A. Using an incorrect power supply may damage the device.
- Do not short-circuit the battery terminals.
- Operate the device in a well-ventilated area.
- The device features over-temperature protection with audible and visual alarms. If an alarm sounds, disconnect the power and allow the device to cool.
- Keep the device away from water, moisture, and extreme temperatures.
- This device is not a toy. Keep out of reach of children.
3. Product Overview
The Gaqqee BT210 is a dual-channel tester designed to measure the capacity of 18650 lithium-ion batteries. It supports various operating modes including automatic testing, charging, and discharging, providing comprehensive battery analysis.
3.1. Key Features
- Power-off memory function: Automatically saves the most recent measurement data (curves are not saved).
- Audible and visual alarm function: Over-temperature protection with alerts for enhanced safety.
- Screen-off timer: Adjustable screen-off time for energy efficiency.
- Voltage and current waveform display: Provides a clear overview of charging and discharging.
- Independent channels: Each channel operates independently without interference.
- Chinese/English language switching.
- Multi-interface display: Main interface, voltage/current waveforms, historical data.
3.2. Components
Refer to the diagram below for an identification of the main components of the BT210 tester.
Image Description: A top-down view of the Gaqqee BT210 battery tester with numbered and lettered labels pointing to various parts. This image details the physical layout and controls of the device.
- Type-C 5V power supply interface (DC IN 5V/2A)
- Type-C communication interface (reserved function)
- Channel 1 (CH1) 18650 battery holder
- Channel 2 (CH2) 18650 battery holder
- Cooling fan
- Display screen
- Menu/Menu button
- Adjust/Set button
- Start/Stop/Ta/To button
- Channel/ChN button (A)
- CH1 channel status indicator light (B)
- CH2 channel status indicator light (C)
- Buzzer (D)
Video Description: A short demonstration video showcasing the Gaqqee BT210 battery tester from various angles, highlighting its compact design and dual battery slots.
4. Setup
- Power Connection: Connect a DC 5V/2A power adapter to the Type-C power supply interface (1) on the device.
- Battery Insertion: Insert one or two 18650 lithium-ion batteries (charged to 4.2V) into the respective battery holders (3 and 4), ensuring correct polarity (+ and -).
- Initial Power On: The device will power on automatically once connected to power.
5. Operating Instructions
5.1. Language Switching
To switch between Chinese and English:
- Press and hold the "Menu" button (7) while powering on the device.
- Release the button to switch the display language.
Image Description: A close-up view of the battery tester with text overlay "Switch between Chinese and English" and instructions: "Press and hold the 'Menu' button to turn on the power; release the button to switch modes."
5.2. Operating Modes
The device supports three main operating modes: Auto mode, Charge mode, and Discharge mode. Use the "Menu" button (7) to navigate through modes and the "Adjust/Set" button (8) to confirm or adjust settings.
- Auto Mode: Performs an automatic charge-discharge cycle to determine battery capacity.
- Charge Mode: Charges the inserted battery to its full capacity (up to 4.2V).
- Discharge Mode: Discharges the battery to a set voltage level, measuring the energy discharged.
Each channel operates independently. Use the "Channel/ChN" button (A) to switch the display between channels or view both simultaneously if supported by the interface.
Image Description: A top-down view of the battery tester with text overlay "Switch channel display" and "Each channel is independent and does not interfere with the others."
5.3. Multi-Interface Display
The device offers multiple display interfaces for comprehensive data viewing:
- Main Interface: Shows real-time voltage, current, capacity (mAh), and energy (mWh).
- Historical Data: Displays accumulated charge/discharge data.
- Voltage and Current Waveforms: Visualizes the charging and discharging process over time.
Image Description: A composite image showing three different screen displays: "Main Screen" with real-time data, "Historical Data" with accumulated values, and a "Line graph" showing voltage/current curves.
Image Description: A perspective view of the battery tester with text overlay "Supports display of voltage-current curves" and "The charging and discharging process is clearly visible."
5.4. Screen Timeout (Sleep Timer)
You can set the screen to turn off after a period of inactivity to save energy.
- Navigate to the screen timeout setting via the "Menu" button (7).
- Use the "Adjust/Set" button (8) to set the timeout duration from 0 to 9 minutes (default is 0 minutes, meaning the screen remains on).
Image Description: A perspective view of the battery tester with text overlay "Sleep Timer" and "You can set the screen timeout to save energy and be more environmentally friendly."
6. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Do not use abrasive cleaners or solvents.
- Ensure the cooling fan (5) is free from obstructions to maintain proper airflow.
- Store the device in a cool, dry place when not in use.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Incorrect power supply; loose connection | Ensure DC 5V/2A power supply is used and securely connected. |
| Over-temperature alarm sounds | Device overheating; fan obstructed | Disconnect power, allow to cool. Check if cooling fan is clear of obstructions. Operate in a well-ventilated area. |
| Inaccurate readings | Battery not properly seated; faulty battery | Ensure battery is correctly inserted with proper polarity. Test with a known good battery. |
| Display is blank or frozen | Temporary software glitch | Disconnect and reconnect power to restart the device. |
8. Specifications
| Feature | Detail |
|---|---|
| Number of Channels | 2 x 18650 lithium-ion batteries |
| Compatible Batteries | 18650 lithium batteries charged at 4.2V (excluded) |
| Cooling Method | Active cooling (fan) |
| Power Supply | DC 5V/2A |
| Standby Time | 1-9 minutes, adjustable (default 1 minute) |
| Operating Modes | Auto mode, Charge mode, Discharge mode |
| Over-temperature Protection | Supported (automatically detected by program) |
| Initial Charge Voltage | 3.7-4.2V |
| Initial Discharge Voltage | 2.0-3.6V |
| Recharge Voltage | 3.0-4.2V |
| Cut-off Current | 0.1-0.3A |
| Capacity Measurement Range | 0-99,999 mAh |
| Energy Measurement Range | 0-99,999 mWh |
| Voltage Accuracy | ±(1% + 2 digits) |
| Current Accuracy | ±(1% + 5 digits) |
| Discharge Voltage | 2.5V-3.5V, 11 adjustable levels |
| Discharge Current | Maximum approx. 1A, non-adjustable |
| Status Display | LED indicator, buzzer |
| Screen Timeout | Supported, adjustable 0-9 minutes (default 0, screen remains on) |
| Product Dimensions | 100 × 100 × 29 mm |
Image Description: A perspective view of the battery tester with dimensions labeled: 100mm length, 100mm width, and 29mm height.
9. Warranty and Support