1. Introduction
This manual provides essential information for the assembly, installation, operation, and troubleshooting of your Aninerel Hybrid Solar Inverter. Please read it carefully before installation and operation, and keep it for future reference. This inverter is designed for both on-grid and off-grid needs, featuring a built-in MPPT controller for efficient solar energy harvesting and pure sine wave output for sensitive appliances.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, please follow the required specifications to select appropriate cable sizes.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists for a tool to spark or short-circuit batteries or other electrical parts, which could cause an explosion.
- Please strictly follow the installation procedure when disconnecting AC or DC terminals.
- A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Only qualified service persons are able to service this device. If errors persist after troubleshooting, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Product Overview
The Aninerel Hybrid Solar Inverter is an all-in-one unit designed for comprehensive power management. It features a user-friendly interface and robust connectivity options.

3.1. Components
- LCD display
- Function buttons (ESC, UP, DOWN, ENTER)
- RGB indicator
- Grounding terminal
- RS232 communication port
- RS485 communication port
- AC input terminals
- Main out terminals
- Second out terminals (available on 4.2KW, 6.2KW, 11KW models)
- Battery input terminals
- PV input terminals
- Power on/off switch
4. Setup and Installation
4.1. Unpacking and Inspection
Before installation, inspect the unit for any damage. Ensure the package contains:
- The inverter unit x 1
- User manual x 1 (PDF version available here)
4.2. Preparation
Before connecting any wirings, remove the bottom cover by unscrewing the two retaining screws.

4.3. Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface (concrete or other non-combustible surface only).
- Install at eye level for easy LCD display reading.
- Ambient temperature should be between 0°C and 55°C for optimal operation.
- Recommended installation position is vertically on a wall.
- Ensure sufficient clearance around the unit for heat dissipation and wiring access.

4.4. Battery Connection
WARNING: All wiring must be performed by qualified personnel.
Install a separate DC over-current protector or disconnect device between the battery and inverter. Ensure correct polarity. Use appropriate cable sizes as per the table below:
| Model | Maximum Amperage | Battery Capacity | Wire Size | Cable mm² | Terminal Size (L x W x D) | Torque Value |
|---|---|---|---|---|---|---|
| 4.2KVA | 175A | 200AH | 1AWG | 50 | 37 x 15.3 x 6.4 mm | 4~6 Nm |
| 6.2KVA | 130A | 200AH | 2AWG | 35 | 37 x 15.3 x 6.4 mm | 4~6 Nm |
Steps:
- Make positive and negative cables based on recommended terminal size.
- Connect all battery packs as units require.
- Insert battery cable flatly into the battery connector of the inverter and ensure bolts are tightened with a torque of 4~6Nm. Verify correct polarity.
4.5. AC Input/Output Connection
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
Install a separate AC breaker between the inverter and the AC input power source. The recommended AC breaker spec is 50A. Do not mis-connect input and output connectors.
| Model | Gauge | Torque Value |
|---|---|---|
| 4.2KVA | 10AWG | 1.4~1.6Nm |
| 6.2KVA | 10AWG | 1.4~1.6Nm |
Steps:
- Before making AC input/output connection, open the DC protector or disconnector.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (Ground (yellow-green), L-LINE (brown or black), N-Neutral (blue)) and tighten terminal screws. Connect PE protective conductor first.
- Insert AC output wires according to polarities and tighten terminal screws. Connect PE protective conductor first.
4.6. PV Connection
WARNING: All wiring must be performed by qualified personnel.
Before connecting to PV modules, install a DC circuit breaker between the inverter and PV modules. Use appropriate cable sizes.
| Model | Typical Amperage | Cable Size | Torque |
|---|---|---|---|
| 4.2KVA | 27A | 10 AWG | 1.4~1.6 Nm |
| 6.2KVA | 27A | 10 AWG | 1.4~1.6 Nm |
When selecting PV modules, consider the following:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.

Steps for PV Module Wire Connection:
- Remove 6mm of insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Ensure the wires are securely connected.
4.7. Final Assembly
After connecting all wirings, replace the bottom cover by screwing in the two screws.
5. Operation
5.1. Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.
5.2. Operation and Display Panel
The front panel features an LCD display, three indicators, and four function keys to monitor operating status and input/output power information.
| RGB Indicator | Color | State | Messages |
|---|---|---|---|
| Inverter mode | Green | Solid On | Output is powered by battery or PV; battery is fully charged or not charged. |
| Flashing | Battery is charging with 2s-on and 1s-off. | ||
| AC mode | Blue | Solid On | Output is powered by AC or PV in AC mode; battery is fully charged or not charged. |
| Flashing | Battery is charging with 2s-on and 1s-off. | ||
| Standby mode | Cyan | Solid On | Battery is fully charged or not charged. |
| Flashing | Battery is charging with 2s-on and 1s-off. | ||
| Fault mode | Red | Solid On | Fault occurs in the inverter. |
| Bypass mode | Purple | Solid On | Working in AC mode without charging. |
| Charging mode | Yellow | Solid On | Battery is fully charged, when switch is off. |
| Flashing | Battery is charging, when switch is off. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3. LCD Display Description
The LCD display shows various information across five areas. Information can be switched by pressing the UP/DOWN keys.
- Area 1: PV data (voltage, current, power)
- Area 2: Battery data (voltage, current, power, SOC)
- Area 3: AC output data (voltage, current, power, percentage, frequency)
- Area 4: AC input data (voltage, current, power, percentage, frequency)
- Area 5: Setting program code, Eco mode, buzzer status, error, warning
LCD Data Polling Display Mode:
- Simultaneously polling data: Press "UP" or "DOWN" to show all data from area 1-4 simultaneously. Press ESC to return to initial data.
- Independent polling data: Press "ENTER" to make a circle icon flash, then use "UP" or "DOWN" to display data for that specific area. Repeat for other areas.
5.4. LCD Settings
To enter setting mode, press and hold the "ENTER" key for 3 seconds. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit. Key settings include:
- Program 01: Output source priority (Utility first, Solar first, SBU priority, SUB priority, SUF priority)
- Program 02: Maximum charging current (60A default)
- Program 03: AC input voltage range (Appliances, UPS, Generator)
- Program 05: Battery type (AGM, Flooded, User-Defined, LI2, LI4, LIB)
- Program 06: Auto restart when overload occurs (Restart disable/enable)
- Program 07: Auto restart when over temperature occurs (Restart disable/enable)
- Program 08: Output voltage (220V, 230V, 240V)
- Program 09: Output frequency (50Hz, 60Hz)
- Program 10: Auto bypass (Manual/Auto)
- Program 11: Maximum utility charging current (30A default)
- Program 12: Setting voltage point back to utility source
- Program 13: Setting voltage point back to battery mode
- Program 16: Charger source priority (Solar first, Solar and Utility, Only Solar)
- Program 18: Buzzer mode (Mode1-4)
- Program 19: Auto return to default display screen (Return to default/Stay at latest)
- Program 20: Backlight control (Backlight on/off)
- Program 23: Overload bypass (Bypass disable/enable)
- Program 25: Modbus ID Setting (001-247)
- Program 26: Bulk charging voltage (C.V voltage)
- Program 27: Floating charging voltage
- Program 29: Setting cut off voltage point or SOC percentage on the second output (OP2)
- Program 31: Setting cut off voltage point or SOC percentage on the Main output (OP1)
- Program 32: Bulk charging time (C.V stage)
- Program 33: Battery equalization (Enable/Disable)
- Program 34: Battery equalization voltage
- Program 35: Battery equalized time
- Program 36: Battery equalized timeout
- Program 37: Equalization interval
- Program 39: Equalization activated immediately (Enable/Disable)
- Program 41: Automatic activation for lithium battery (Disable/Auto)
- Program 42: Manual activation for lithium battery (Activation/Disable)
- Program 43: OP2 Output Enable (Enable/Disable)
- Program 46: Maximum discharge current protection
- Program 47: Setting the OP2 overload warning point
- Program 49: RGB mode - Checking RGB Indicator table (Mode 1-5)
- Program 50: Lithium battery activation time
6. Maintenance
6.1. Battery Equalization
The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, extending battery life. It is recommended to equalize the battery periodically.
To apply equalization:
- Enable battery equalization in LCD setting program 33.
- Set the equalization interval in program 37, or activate immediately in program 39.
The controller will enter the Equalize stage when the set interval is reached or immediately activated. During this stage, the controller charges the battery until it reaches the equalization voltage, then maintains this voltage until the set equalized time is reached.
6.2. Lithium Battery Connection and Setting
If using a lithium battery, ensure it is a compatible model. Connect the RS485 port of the battery to the BMS (RS485) communication port of the inverter. This cable facilitates communication for advanced BMS control.
Setting for Lithium Battery without Communication:
If your lithium battery does not communicate via RS485, you must manually configure the inverter settings. It is recommended to set the battery type to "LIB" in program 05. Alternatively, you can manually set the following parameters based on your battery's BMS specifications:
- Max charging voltage
- Max charging current
- Discharging protection voltage
Then, configure the following programs:
- Program 05: Set battery type to "LIB".
- Program 26: Set C.V voltage as Max charging voltage of BMS - 0.5V.
- Program 27: Set floating charging voltage as C.V voltage.
- Program 29: Set Low DC cut-off voltage as discharging protection voltage.
- Program 02: Set Max charging current (must be less than the Max charging current of BMS).
- Program 12: Set voltage point back to utility source when selecting "SBU priority". The value must be ≥ Low DC cut-off voltage + 2V.
Remark: It is best to complete these settings before turning on the inverter (only LCD display, no output). After finishing settings, restart the inverter.
7. Troubleshooting
This section provides guidance for common issues. For persistent problems, refer to the full PDF manual or contact customer support.
7.1. Fault Reference Code
| Fault Code | Fault Event |
|---|---|
| 01 | Over temperature of inverter module |
| 02 | Over temperature of DCDC module |
| 03 | Battery voltage is too high |
| 04 | Over temperature of PV module |
| 05 | Output short circuited. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 10 | PV over current |
| 11 | PV over voltage |
| 12 | DCDC over current |
| 13 | Over current or surge |
| 14 | Bus voltage is too low |
| 15 | Inverter failed (Self-checking) |
| 18 | Op current offset is too high |
| 19 | Inverter current offset is too high |
| 20 | DC/DC current offset is too high |
| 21 | PV current offset is too high |
| 22 | Output voltage is too low |
| 23 | Inverter negative power |
| 24 | Op2 current offset is too high |
7.2. Warning Indicator
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 02 | Temperature is too High | Beep three times every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 14 | Fan blocked | None |
| 15 | PV energy is low | Beep twice every 3 seconds |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second |
| 21 | Lithium Battery over current | None |
| 22 | The load exceeds the set value of program 47 | None |
| E9 | Battery equalization | None |
| b8 | Battery is not connected | None |
8. Specifications
The Aninerel Hybrid Solar Inverter is available in multiple power configurations. Please refer to the specific model's specifications below.
8.1. 2000W-12V-60A Model Specifications

8.2. 4200W-24V-120A Model Specifications

8.3. 6200W-48V-120A Model Specifications

8.4. 11000W-48V-160A Model Specifications

8.5. General Specifications (All Models)
| Parameter | 4.2KVA | 6.2KVA |
|---|---|---|
| Operating Temperature Range | -10°C to 55°C | |
| Storage temperature | -15°C ~ 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 368x328x120 | |
| Net Weight, kg | 7.0 | 8.0 |
9. User Tips
- Voltage Compatibility: This inverter is designed for 220V output. It is not suitable for 110V equipment. Please ensure your appliances match the inverter's output voltage.
- Battery Type Selection: If using a lithium battery without RS485 communication, carefully follow the manual settings (Program 05, 26, 27, 29, 02, 12) to avoid issues. It's best to configure these settings before the inverter is fully operational.
- Overload Protection: Pay attention to the overload warning indicators and reduce connected loads if necessary to prevent faults.