MYOSLIM EMSzero

Contents

EMSzero MYOslim Sculpt Machine User Manual

Model: EMSzero

1. Introduction

The EMSzero MYOslim Sculpt Machine utilizes advanced High-Intensity Focused Electromagnetic (HI-EMT) technology to induce powerful muscle contractions. This process promotes muscle growth and internal structural remodeling, leading to enhanced muscle tone and definition. Additionally, intense muscle contractions contribute to significant fat degradation by releasing fatty acids from triglycerides, which are then metabolized by the body over several weeks.

The device features a user-friendly touchscreen display for easy operation and real-time monitoring of treatment parameters. It offers flexible upgrade options to meet evolving therapeutic needs.

2. Safety Information

2.1. Precautions Before Use

  • Do not use the device when feeling full, at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting operation, touch the probe vertically on the skin, then turn on the main unit switch and adjust the intensity of the operating mode.
  • Adjust the intensity gradually from the lowest level, increasing it sequentially according to the user's skin tolerance.
  • It is forbidden to eat or drink during operation, and avoid eating for one hour after the operation.

2.2. Contraindications

Do not use the EMSzero MYOslim Sculpt Machine if any of the following conditions apply:

  • Open wounds on the skin (or avoid using on wounded areas).
  • Patients with heart conditions (such as arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant or lactating women, or during menstruation.
  • Patients who have undergone major surgery or have diabetes.
  • Presence of any metal in the body.
  • Individuals with cerebrovascular disease (e.g., stroke patients).

3. Device Components and Accessories

3.1. Main Unit Front and Rear Panel

The main unit features a display screen, power button, and connections for the treatment handles.

Front view of the EMSzero machine with two handles, showing the display and a CE mark.
Front view of the EMSzero machine, highlighting the display and handles.
Rear view of the EMSzero machine, showing handle connections and power switch.
Rear view of the EMSzero machine, showing handle connections and power switch.

Note: The handle can only be used with the original machine and cannot be used interchangeably.

3.2. Handles

The device comes with various handle types for different applications. Ensure you use the correct handle for the desired treatment area.

Image of the 2-handle RF applicator. Image of the 4-handle RF applicator. Image of the 5-handle RF applicator.
Various handle types: 2-handle RF, 4-handle RF, and 5-handle RF.

3.3. List of Accessories

Item No. Name Quantity Image
1 Host Machine 1 set Host Machine
2 Handle 2 Handle
3 Cushion/Belt (80cm, 90cm, 100cm) 3 Cushion/Belt
4 Power Cable 1 Power Cable
5 Electronic Manual 1 copy

4. Setup Instructions

4.1. Install the Handle Support

Attach the handle support to the main unit. Ensure it is securely fastened. A screwdriver may be needed for this step.

Diagram showing how to install the handle support on both sides of the machine.
Handle support installation diagram.

4.2. Handle Film and Installation

Apply the black protective film to the functional part of the handle. Align the handle with the orifice on the machine and fix it with the clip. Lock the keychain in place.

Diagram showing handle film application and handle attachment to the machine.
Handle film application and attachment.

4.3. Connect the Power Supply

Connect one end of the power cable to the machine and the other end to a reliable grounded power outlet. Do not connect multiple machines to the same outlet.

Diagram showing power cable connection to the machine and wall socket.
Power connection diagram.

4.4. Powering On/Off

  1. Move the manual switch on the rear panel to the "O" position (off).
  2. Press the button on the front panel to turn on (single click).
  3. To turn off, press and hold the power button on the front panel.
Diagram showing the rear power switch and front power button for turning the device on and off.
Power switch and button operation.

5. Operation Instructions

5.1. Handle Calibration

The handle must be calibrated each time it is installed or replaced. When replacing the handle, the machine must be turned off. It is not possible to replace it with the machine turned on.

5.2. Navigation Controls and Therapy Adjustment

The device features a touchscreen interface for adjusting therapy parameters. The treatment interface displays remaining time, channels, treatment types, and accessory usage.

Screenshot of the device interface showing pattern selection and therapy parameters.
Device interface for pattern selection and therapy adjustment.

Mode 1 Operation:

  1. From the main screen, select 'Mode 1'.
  2. Adjust the treatment time, intensity, and energy levels using the on-screen controls.
  3. Select the desired handle (A or B) and region for treatment.
  4. Press the start/pause button to begin or pause the treatment.

Mode 2 Operation:

  1. From the main screen, select 'Mode 2'.
  2. Adjust the treatment time, intensity, and frequency (3 different periods) using the on-screen controls.
  3. Select the desired handle (A or B) and region for treatment.
  4. Press the start/pause button to begin or pause the treatment.

Note: If the client requests a pause, you can click the start/pause button to pause the work, and once the work is completed, you can click the return key directly to return.

5.3. System Settings

Access the system settings to configure language, sound, brightness, date & time, and technical parameters.

Screenshot of the system settings interface showing options for language, sound, brightness, date & time, and technical settings.
System settings interface.

5.4. Therapy Preparation

  1. Communicate with the patient about the procedure.
  2. Ensure the patient is in good health and has no contraindications.
  3. Ensure the patient is well-hydrated.
  4. Advise the patient to wear appropriate clothing that allows access to the treatment area.
  5. Avoid eating large meals before the treatment.
  6. Familiarize yourself with the treatment process.
  7. Avoid alcohol consumption before treatment.

5.5. Handle Placement

Proper placement of the handles is crucial for effective treatment. Refer to the diagrams below for guidance on common treatment areas:

Diagrams illustrating handle placement for abdomen, buttocks, and arm treatments.
Handle placement for various body areas (abdomen, buttocks, arms).

Use the controller model you purchased and follow the official manufacturer's documentation for the best experience. If you have any questions, please contact customer service for assistance.

6. Maintenance

6.1. Daily Inspection

Regularly inspect the instrument and its components. Verify that the power outlet has a reliable ground connection. Check if the instrument's power cable is damaged before use, and discontinue use if damage is found.

6.2. Cleaning

The instrument should be cleaned periodically to ensure hygiene and proper functioning. The device casing can be cleaned with a damp cloth, soapy water, or a neutral detergent while the instrument is turned off.

  • The machine logo is painted using a silk-screen printing process.
  • The rest of the parts are painted with spray paint. To clean them, use cotton paper towels or common toilet paper moistened with water. Do not use detergents with alcohol.
  • Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use.
  • Do not immerse the accessories directly in alcohol-based detergent; clean with a pure cotton cloth.

6.3. Fuse Replacement

The fuse is located under the handle joint, at the back of the machine. A spare fuse is included. To avoid electric shock, turn off the appliance and unplug it before replacing the fuse.

6.4. Storage and Transportation

Storage: The instrument should be stored in its original packaging box, placed in a well-ventilated room. The packaging box should be padded, the ambient temperature should be between -10°C and 40°C, and the relative humidity should not exceed 93%. It should not be placed in harmful gases, near flammable, explosive substances, or corrosive gases.

Transportation: The instrument in its packaged condition is suitable for road, rail, air, and water transport. During loading, unloading, and transport, severe vibrations and impacts should be avoided. It should not be affected by humidity or mixed with flammable and corrosive substances. Specific requirements are detailed in the order contract.

7. Troubleshooting

Problem Cause Solution
Device does not turn on Power plug not inserted into socket Check power connection
Power switch not turned on Check power switch
Power fuse failure Replace the fuse
Handle not working Handle not securely attached Reattach the handle

8. Specifications

Attribute Value
Brand Name MYOSLIM
Item Type Massage & Relaxation
Power Supply Alternating Current
Input Voltage AC 110V-220V 50/60Hz
Max Output Power 0-6500W
Frequency 5-200 Hz
Screen Size 8.0 inches
Material Composite Material, ABS+Steel
Type Desktop
Application For Commercial, Beauty Center & Clinic
Origin Mainland China
Certificates CE, ROHS

8.1. Electromagnetic Compatibility (EMC)

The device complies with IEC 61000-4-3:2020 standards for radiated electromagnetic immunity. Test levels include 30 V/m with 80% AM modulation at 1 kHz.

Block diagram of the EMC test setup, showing the test chamber, EUT, amplifier, signal generator, and monitoring equipment.
EMC Test Setup Diagram.

9. Warranty and Support

9.1. Warranty Policy

  • The main machine comes with a one-year warranty from the date of purchase (excluding fragile parts and other products outside the warranty scope or expired warranty period).
  • Accessories have a 3-month warranty (excluding human-caused damage).
  • If a quality problem attributable to the company occurs within one year from the date of purchase, a free warranty is provided (requires warranty card and purchase invoice).
  • If the instrument breaks down and needs to be returned for repair, the buyer is responsible for the cost of return shipping within six months from the date of purchase. The seller will cover the shipping costs; the buyer will cover all shipping costs for more than half a year.

9.2. Exclusions from Free Warranty Service

Free warranty service is not provided for user failures caused by personal reasons, including:

  • Failures caused by unauthorized disassembly and modification of the product.
  • Failures caused by accidental drops.
  • Failures caused by lack of reasonable maintenance.
  • Failure to operate according to the instructions in the user manual.

9.3. After-sales Service

After the warranty period, contact the manufacturer directly for paid after-sales service. For equipment repair, contact the commercial department or the company's distributor. Do not repair without authorization. Any unauthorized unpacking will not be covered by our company's warranty.

For further assistance, you can refer to the official user manual PDF: View User Manual (PDF)

10. User Tips

  • The machine is small and lightweight, making it convenient for home use.
  • It is easy to operate and provides a gentle and comfortable effect.
  • If you encounter any issues, customer service is generally responsive and helpful, often providing video tutorials for quick problem resolution.
  • The device's data and settings are reported to be accurate and beneficial for users.
  • The machine can be operated while lying down, offering flexibility in use.

11. Video Demonstration

Watch this video for a visual guide on the EMSzero machine's setup, interface navigation, and how to apply the handles for treatment.

Video: EMSzero MYOslim Sculpt Machine Setup and Operation.

12. Manufacturer

Guangzhou Xinwei Tecnología Electrónica Co., Ltd.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.