1. Introduction
The EMSzero MYOslim Sculpt Machine utilizes advanced High-Intensity Focused Electromagnetic (HI-EMT) technology to induce powerful muscle contractions. This process promotes muscle growth and internal structural remodeling, leading to enhanced muscle tone and definition. Additionally, intense muscle contractions contribute to significant fat degradation by releasing fatty acids from triglycerides, which are then metabolized by the body over several weeks.
The device features a user-friendly touchscreen display for easy operation and real-time monitoring of treatment parameters. It offers flexible upgrade options to meet evolving therapeutic needs.
2. Safety Information
2.1. Precautions Before Use
- Do not use the device when feeling full, at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting operation, touch the probe vertically on the skin, then turn on the main unit switch and adjust the intensity of the operating mode.
- Adjust the intensity gradually from the lowest level, increasing it sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during operation, and avoid eating for one hour after the operation.
2.2. Contraindications
Do not use the EMSzero MYOslim Sculpt Machine if any of the following conditions apply:
- Open wounds on the skin (or avoid using on wounded areas).
- Patients with heart conditions (such as arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant or lactating women, or during menstruation.
- Patients who have undergone major surgery or have diabetes.
- Presence of any metal in the body.
- Individuals with cerebrovascular disease (e.g., stroke patients).
3. Device Components and Accessories
3.1. Main Unit Front and Rear Panel
The main unit features a display screen, power button, and connections for the treatment handles.
Note: The handle can only be used with the original machine and cannot be used interchangeably.
3.2. Handles
The device comes with various handle types for different applications. Ensure you use the correct handle for the desired treatment area.
3.3. List of Accessories
| Item No. | Name | Quantity | Image |
|---|---|---|---|
| 1 | Host Machine | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| 3 | Cushion/Belt (80cm, 90cm, 100cm) | 3 | ![]() |
| 4 | Power Cable | 1 | ![]() |
| 5 | Electronic Manual | 1 copy |
4. Setup Instructions
4.1. Install the Handle Support
Attach the handle support to the main unit. Ensure it is securely fastened. A screwdriver may be needed for this step.
4.2. Handle Film and Installation
Apply the black protective film to the functional part of the handle. Align the handle with the orifice on the machine and fix it with the clip. Lock the keychain in place.
4.3. Connect the Power Supply
Connect one end of the power cable to the machine and the other end to a reliable grounded power outlet. Do not connect multiple machines to the same outlet.
4.4. Powering On/Off
- Move the manual switch on the rear panel to the "O" position (off).
- Press the button on the front panel to turn on (single click).
- To turn off, press and hold the power button on the front panel.
5. Operation Instructions
5.1. Handle Calibration
The handle must be calibrated each time it is installed or replaced. When replacing the handle, the machine must be turned off. It is not possible to replace it with the machine turned on.
5.2. Navigation Controls and Therapy Adjustment
The device features a touchscreen interface for adjusting therapy parameters. The treatment interface displays remaining time, channels, treatment types, and accessory usage.
Mode 1 Operation:
- From the main screen, select 'Mode 1'.
- Adjust the treatment time, intensity, and energy levels using the on-screen controls.
- Select the desired handle (A or B) and region for treatment.
- Press the start/pause button to begin or pause the treatment.
Mode 2 Operation:
- From the main screen, select 'Mode 2'.
- Adjust the treatment time, intensity, and frequency (3 different periods) using the on-screen controls.
- Select the desired handle (A or B) and region for treatment.
- Press the start/pause button to begin or pause the treatment.
Note: If the client requests a pause, you can click the start/pause button to pause the work, and once the work is completed, you can click the return key directly to return.
5.3. System Settings
Access the system settings to configure language, sound, brightness, date & time, and technical parameters.
5.4. Therapy Preparation
- Communicate with the patient about the procedure.
- Ensure the patient is in good health and has no contraindications.
- Ensure the patient is well-hydrated.
- Advise the patient to wear appropriate clothing that allows access to the treatment area.
- Avoid eating large meals before the treatment.
- Familiarize yourself with the treatment process.
- Avoid alcohol consumption before treatment.
5.5. Handle Placement
Proper placement of the handles is crucial for effective treatment. Refer to the diagrams below for guidance on common treatment areas:
Use the controller model you purchased and follow the official manufacturer's documentation for the best experience. If you have any questions, please contact customer service for assistance.
6. Maintenance
6.1. Daily Inspection
Regularly inspect the instrument and its components. Verify that the power outlet has a reliable ground connection. Check if the instrument's power cable is damaged before use, and discontinue use if damage is found.
6.2. Cleaning
The instrument should be cleaned periodically to ensure hygiene and proper functioning. The device casing can be cleaned with a damp cloth, soapy water, or a neutral detergent while the instrument is turned off.
- The machine logo is painted using a silk-screen printing process.
- The rest of the parts are painted with spray paint. To clean them, use cotton paper towels or common toilet paper moistened with water. Do not use detergents with alcohol.
- Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use.
- Do not immerse the accessories directly in alcohol-based detergent; clean with a pure cotton cloth.
6.3. Fuse Replacement
The fuse is located under the handle joint, at the back of the machine. A spare fuse is included. To avoid electric shock, turn off the appliance and unplug it before replacing the fuse.
6.4. Storage and Transportation
Storage: The instrument should be stored in its original packaging box, placed in a well-ventilated room. The packaging box should be padded, the ambient temperature should be between -10°C and 40°C, and the relative humidity should not exceed 93%. It should not be placed in harmful gases, near flammable, explosive substances, or corrosive gases.
Transportation: The instrument in its packaged condition is suitable for road, rail, air, and water transport. During loading, unloading, and transport, severe vibrations and impacts should be avoided. It should not be affected by humidity or mixed with flammable and corrosive substances. Specific requirements are detailed in the order contract.
7. Troubleshooting
| Problem | Cause | Solution |
|---|---|---|
| Device does not turn on | Power plug not inserted into socket | Check power connection |
| Power switch not turned on | Check power switch | |
| Power fuse failure | Replace the fuse | |
| Handle not working | Handle not securely attached | Reattach the handle |
8. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Power Supply | Alternating Current |
| Input Voltage | AC 110V-220V 50/60Hz |
| Max Output Power | 0-6500W |
| Frequency | 5-200 Hz |
| Screen Size | 8.0 inches |
| Material | Composite Material, ABS+Steel |
| Type | Desktop |
| Application | For Commercial, Beauty Center & Clinic |
| Origin | Mainland China |
| Certificates | CE, ROHS |
8.1. Electromagnetic Compatibility (EMC)
The device complies with IEC 61000-4-3:2020 standards for radiated electromagnetic immunity. Test levels include 30 V/m with 80% AM modulation at 1 kHz.
9. Warranty and Support
9.1. Warranty Policy
- The main machine comes with a one-year warranty from the date of purchase (excluding fragile parts and other products outside the warranty scope or expired warranty period).
- Accessories have a 3-month warranty (excluding human-caused damage).
- If a quality problem attributable to the company occurs within one year from the date of purchase, a free warranty is provided (requires warranty card and purchase invoice).
- If the instrument breaks down and needs to be returned for repair, the buyer is responsible for the cost of return shipping within six months from the date of purchase. The seller will cover the shipping costs; the buyer will cover all shipping costs for more than half a year.
9.2. Exclusions from Free Warranty Service
Free warranty service is not provided for user failures caused by personal reasons, including:
- Failures caused by unauthorized disassembly and modification of the product.
- Failures caused by accidental drops.
- Failures caused by lack of reasonable maintenance.
- Failure to operate according to the instructions in the user manual.
9.3. After-sales Service
After the warranty period, contact the manufacturer directly for paid after-sales service. For equipment repair, contact the commercial department or the company's distributor. Do not repair without authorization. Any unauthorized unpacking will not be covered by our company's warranty.
For further assistance, you can refer to the official user manual PDF: View User Manual (PDF)
10. User Tips
- The machine is small and lightweight, making it convenient for home use.
- It is easy to operate and provides a gentle and comfortable effect.
- If you encounter any issues, customer service is generally responsive and helpful, often providing video tutorials for quick problem resolution.
- The device's data and settings are reported to be accurate and beneficial for users.
- The machine can be operated while lying down, offering flexibility in use.
11. Video Demonstration
Watch this video for a visual guide on the EMSzero machine's setup, interface navigation, and how to apply the handles for treatment.
12. Manufacturer
Guangzhou Xinwei Tecnología Electrónica Co., Ltd.