1. Introduction and Overview
This product is an inline pipe-mounted digital flow meter designed for measuring the flow of water and compatible chemical liquids. It is manufactured with corrosion-resistant PVC material and features an LCD display for real-time flow visualization. The meter supports RS485 Modbus RTU communication, making it suitable for industrial monitoring, irrigation systems, and water treatment applications. The device is intended for full-pipe liquid flow conditions and indoor installation environments.
The PVC-LCD digital flow meter is designed for pipe sizes from DN15 to DN80. The display screen is not waterproof, so please ensure proper dust and water protection during installation and use. Outdoor installation is not recommended.
2. Specifications
The following table details the general parameters for the flow meter:
| Parameter | Description |
|---|---|
| Working Voltage | 10~30VDC |
| Working Current | 60mA Max (30VDC) |
| Measurable Liquids | Water or chemical liquids |
| Working Pressure | 5kg/cm² (approx. 0.5 MPa) |
| Response Time | Real-time |
| Protection Level | IP65 (excluding display surface) |
| Operating Temperature | -10°C~70°C |
| Instantaneous Flow Range (LPM) | 0~999.99 |
| Total Flow Range (FTM) | 0~999999 |
| Instant Flow Output Mode | NPN (150mA Max) |
| Total Flow Output Mode | NPN (150mA Max) |
| Communication Interface (Display Type) | RS485 (Modbus RTU protocol) |
| Housing Material | UPVC |
| K-value | User-adjustable for calibration |
Pipe Diameter Selection
Confirm pipe size before ordering. Buyer covers return shipping for incorrect size.
| Nominal Diameter | Pipe Dimensions |
|---|---|
| DN15 | Inner diameter 20.3mm, Outer diameter 27mm PVC pipe |
| DN20 | Inner diameter 25.4mm, Outer diameter 32mm PVC pipe |
| DN25 | Inner diameter 25mm, Outer diameter 32mm PVC pipe |
| DN32 | Inner diameter 32mm, Outer diameter 40mm PVC pipe |
| DN40 | Inner diameter 40mm, Outer diameter 50mm PVC pipe |
| DN50 | Inner diameter 50mm, Outer diameter 63mm PVC pipe |
| DN65 | Inner diameter 65mm, Outer diameter 75mm PVC pipe |
| DN80 | Inner diameter 80mm, Outer diameter 90mm PVC pipe |
RS-485 Communication Series Flow Ranges
| Model | Flow Range | Material |
|---|---|---|
| DN25 | 20-280L/min | UPVC |
| DN32 | 40-460L/min | UPVC |
| DN40 | 50-750L/min | UPVC |
| DN50 | 60-1160L/min | UPVC |
| DN65 | 80-1980L/min | UPVC |
| DN80 | 100-3000L/min | UPVC |
3. Setup and Installation
Before installation, confirm that the pipe diameter matches the meter specification and that the liquid is compatible with PVC material. Ensure the pipeline is clean and free from debris.
Install the flow meter inline with the arrow direction aligned with the actual flow direction. Full-pipe liquid flow must be maintained during operation.
4. Wiring Guide
Connect the power supply according to the rated voltage range (10-30VDC). For RS485 models, connect the communication lines following Modbus RTU wiring conventions.
5. Operating Instructions
Power on the device and allow it to initialize. The LCD will display instantaneous and total flow values. If required, adjust the K-value and unit settings through the display interface according to the application requirements. During operation, keep the flow rate within the specified measurement range to ensure valid signal output.
Digital Display Interface
6. Precautions
- The LCD display is not waterproof. Additional dustproof and waterproof protection must be applied if used in humid environments. Outdoor installation is not recommended.
- Do not exceed the rated pressure, temperature, or voltage limits, as this may result in damage or inaccurate readings.
- Avoid strong vibration, direct sunlight, and rapid temperature changes during operation.
- If the flow rate is too low, the device may not output a valid signal.
- This product operates with DC electrical power. Improper wiring may cause electric shock or equipment damage.
- The device is intended for liquid flow measurement only. Do not use with gas or explosive media.
- The display unit is not waterproof and must be protected from water ingress.
- Keep out of reach of children.
7. Maintenance
- Store the product in a dry, well-ventilated environment when not in use.
- Clean the exterior of the meter using a soft cloth. Do not use corrosive cleaning agents.
- For long-term storage, disconnect the power supply and ensure the internal flow path is dry.
- Periodic inspection is recommended to verify stable signal output and secure electrical connections.
8. User Tips
- The device is typically well-packaged, making initial setup straightforward.
- For gardening irrigation, the total volume control feature works smoothly and effectively.
- Always ensure the pipeline is clean and free from debris before installation for optimal performance and accurate readings.
9. Troubleshooting
- No Signal Output: If the device is not outputting a valid signal, check if the flow rate is too low. Ensure full-pipe flow is maintained for best performance.
- Display Issues: If the LCD display is not working or showing incorrect readings, verify all power connections are secure. Also, ensure the operating temperature and pressure are within the specified limits (-10°C to 70°C and 5kg/cm² respectively).
- Inaccurate Readings: Check for debris in the pipeline or ensure the K-value is correctly calibrated for your specific application.
10. Applications
The SONGGER PVC LCD Electromagnetic Pipeline Flow Meter is suitable for a wide range of applications, including:
- Water Purification: Provides accurate flow monitoring and control to improve the efficiency and stability of water filtration systems.
- Electroplating Cleaning: Ideal for monitoring chemical liquid flow in electroplating and industrial cleaning applications.
- Single Crystal Silicon Cleaning: Delivers stable and reliable performance for precision cleaning processes in semiconductor manufacturing.
- Ultrafiltration & Reverse Osmosis Systems: Designed for advanced filtration equipment that requires accurate and consistent flow measurement.
- Agricultural Irrigation: Used for precise water flow measurement in irrigation systems.
11. Compliance Disclaimer
This document is provided for product instruction purposes only. It does not constitute legal or regulatory compliance advice. The seller is responsible for ensuring that the product and documentation comply with all applicable EU directives and standards in the destination market.
Disposal of this product must comply with the WEEE Directive and local EU regulations for electronic waste.
12. Warranty and Support
For technical consultations, bulk orders, or specific product requirements, please contact us:
- WhatsApp: +86 17306293151
- Email: kellychina68@gmail.com
A detailed user manual in PDF format is also available for download. For more comprehensive information, please refer to the official PDF document: User Manual (PDF).