SONGGER DN15-DN80

Contents

SONGGER PVC LCD Electromagnetic Pipeline Flow Meter

Models: DN15-DN80

Brand: SONGGER

1. Introduction and Overview

This product is an inline pipe-mounted digital flow meter designed for measuring the flow of water and compatible chemical liquids. It is manufactured with corrosion-resistant PVC material and features an LCD display for real-time flow visualization. The meter supports RS485 Modbus RTU communication, making it suitable for industrial monitoring, irrigation systems, and water treatment applications. The device is intended for full-pipe liquid flow conditions and indoor installation environments.

The PVC-LCD digital flow meter is designed for pipe sizes from DN15 to DN80. The display screen is not waterproof, so please ensure proper dust and water protection during installation and use. Outdoor installation is not recommended.

PVC-LCD Pipe Digital Flow Meter with specifications
Figure 1: PVC-LCD Pipe Digital Flow Meter highlighting key specifications like LCD display, 10-30VDC power, 5-3000L/min range, <=1.75MPa pressure, <=60°C temperature, UPVC material, and DN15-80 diameter.

2. Specifications

The following table details the general parameters for the flow meter:

Parameter Description
Working Voltage10~30VDC
Working Current60mA Max (30VDC)
Measurable LiquidsWater or chemical liquids
Working Pressure5kg/cm² (approx. 0.5 MPa)
Response TimeReal-time
Protection LevelIP65 (excluding display surface)
Operating Temperature-10°C~70°C
Instantaneous Flow Range (LPM)0~999.99
Total Flow Range (FTM)0~999999
Instant Flow Output ModeNPN (150mA Max)
Total Flow Output ModeNPN (150mA Max)
Communication Interface (Display Type)RS485 (Modbus RTU protocol)
Housing MaterialUPVC
K-valueUser-adjustable for calibration

Pipe Diameter Selection

Confirm pipe size before ordering. Buyer covers return shipping for incorrect size.

Nominal Diameter Pipe Dimensions
DN15Inner diameter 20.3mm, Outer diameter 27mm PVC pipe
DN20Inner diameter 25.4mm, Outer diameter 32mm PVC pipe
DN25Inner diameter 25mm, Outer diameter 32mm PVC pipe
DN32Inner diameter 32mm, Outer diameter 40mm PVC pipe
DN40Inner diameter 40mm, Outer diameter 50mm PVC pipe
DN50Inner diameter 50mm, Outer diameter 63mm PVC pipe
DN65Inner diameter 65mm, Outer diameter 75mm PVC pipe
DN80Inner diameter 80mm, Outer diameter 90mm PVC pipe

RS-485 Communication Series Flow Ranges

Model Flow Range Material
DN2520-280L/minUPVC
DN3240-460L/minUPVC
DN4050-750L/minUPVC
DN5060-1160L/minUPVC
DN6580-1980L/minUPVC
DN80100-3000L/minUPVC

3. Setup and Installation

Before installation, confirm that the pipe diameter matches the meter specification and that the liquid is compatible with PVC material. Ensure the pipeline is clean and free from debris.

Install the flow meter inline with the arrow direction aligned with the actual flow direction. Full-pipe liquid flow must be maintained during operation.

Diagram showing correct and incorrect installation positions for the flow meter
Figure 2: Correct and Incorrect Installation Positions. Ensure the meter is installed horizontally with the flow arrow matching the liquid direction, and avoid vertical downward flow or partial pipe filling.

4. Wiring Guide

Connect the power supply according to the rated voltage range (10-30VDC). For RS485 models, connect the communication lines following Modbus RTU wiring conventions.

Wiring diagram for LCD & Digital Version and Non-Display Sensor
Figure 3: Wiring Diagram. For LCD & Digital Version: Brown (Power Positive 10-30VDC), Blue (Power Negative), Gray (RS-485 -), Yellow (RS-485 +), Black (Total Flow FTM/OP2 Output Control), White (Instant Flow LPM/OP1 Output Control). For Non-Display Sensor: Red (IN: Connect to Positive), Yellow (OUT: Signal Output Line), Black (GND: Connect to Negative).

5. Operating Instructions

Power on the device and allow it to initialize. The LCD will display instantaneous and total flow values. If required, adjust the K-value and unit settings through the display interface according to the application requirements. During operation, keep the flow rate within the specified measurement range to ensure valid signal output.

Digital Display Interface

Digital Display Version interface with button functions
Figure 4: Digital Display Interface. Shows Instant Flow Rate, Instant Flow Rate Set Value, Liquid Temperature. Buttons include Setting Key, Down Adjustment Key, Up Adjustment Key, and F Key / Left Adjustment Key. OP2 icon lights up when total flow control load is activated. LPM icon lights up for instantaneous flow display. FTM icon lights up for total flow display.
Digital Display Version interface with different display modes
Figure 5: Digital Display Modes. Displays current instantaneous flow or total flow data. Shows set alarm values in instantaneous or total flow mode. When instantaneous + total flow are shown together, only instantaneous flow data is displayed.

6. Precautions

  • The LCD display is not waterproof. Additional dustproof and waterproof protection must be applied if used in humid environments. Outdoor installation is not recommended.
  • Do not exceed the rated pressure, temperature, or voltage limits, as this may result in damage or inaccurate readings.
  • Avoid strong vibration, direct sunlight, and rapid temperature changes during operation.
  • If the flow rate is too low, the device may not output a valid signal.
  • This product operates with DC electrical power. Improper wiring may cause electric shock or equipment damage.
  • The device is intended for liquid flow measurement only. Do not use with gas or explosive media.
  • The display unit is not waterproof and must be protected from water ingress.
  • Keep out of reach of children.

7. Maintenance

  • Store the product in a dry, well-ventilated environment when not in use.
  • Clean the exterior of the meter using a soft cloth. Do not use corrosive cleaning agents.
  • For long-term storage, disconnect the power supply and ensure the internal flow path is dry.
  • Periodic inspection is recommended to verify stable signal output and secure electrical connections.

8. User Tips

  • The device is typically well-packaged, making initial setup straightforward.
  • For gardening irrigation, the total volume control feature works smoothly and effectively.
  • Always ensure the pipeline is clean and free from debris before installation for optimal performance and accurate readings.

9. Troubleshooting

  • No Signal Output: If the device is not outputting a valid signal, check if the flow rate is too low. Ensure full-pipe flow is maintained for best performance.
  • Display Issues: If the LCD display is not working or showing incorrect readings, verify all power connections are secure. Also, ensure the operating temperature and pressure are within the specified limits (-10°C to 70°C and 5kg/cm² respectively).
  • Inaccurate Readings: Check for debris in the pipeline or ensure the K-value is correctly calibrated for your specific application.

10. Applications

The SONGGER PVC LCD Electromagnetic Pipeline Flow Meter is suitable for a wide range of applications, including:

  • Water Purification: Provides accurate flow monitoring and control to improve the efficiency and stability of water filtration systems.
  • Electroplating Cleaning: Ideal for monitoring chemical liquid flow in electroplating and industrial cleaning applications.
  • Single Crystal Silicon Cleaning: Delivers stable and reliable performance for precision cleaning processes in semiconductor manufacturing.
  • Ultrafiltration & Reverse Osmosis Systems: Designed for advanced filtration equipment that requires accurate and consistent flow measurement.
  • Agricultural Irrigation: Used for precise water flow measurement in irrigation systems.
Wide Range of Applications for the flow meter
Figure 6: Visual representation of various applications including Ultrafiltration, Electrode Cleaning, Monocrystalline Silicon Cleaning, Reverse Osmosis, Water Purification, and Agricultural Irrigation.

11. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal or regulatory compliance advice. The seller is responsible for ensuring that the product and documentation comply with all applicable EU directives and standards in the destination market.

Disposal of this product must comply with the WEEE Directive and local EU regulations for electronic waste.

12. Warranty and Support

For technical consultations, bulk orders, or specific product requirements, please contact us:

  • WhatsApp: +86 17306293151
  • Email: kellychina68@gmail.com

A detailed user manual in PDF format is also available for download. For more comprehensive information, please refer to the official PDF document: User Manual (PDF).

Contact information for support
Figure 7: Contact details for support and inquiries.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.