1. Product Overview
The Gaqqee DC8-100V Two-wire Mini Voltmeter and Power Indicator is a versatile device designed for real-time monitoring of battery voltage, percentage, and temperature. It features a compact design, high-precision sensors, and compatibility with various battery types.
Video 1: A 10-second product demonstration showing the voltmeter from various angles.
2. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Gaqqee |
| Model Number | Digital Voltmeter |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE |
| Display Type | Digital Only |
| Power Source | DC |
| Power Supply | DC |
| Voltage measuring range | DC 8-100V |
| Resolution | 0.01V |
| Operating Current | ≤20mA |
| Detection Temperature | -20~80℃ |
| Operating Temperature | -10-50℃ |
| Accuracy Class | ±1% |
| Scanning Speed | 1 scan/500ms |
| Static Power Consumption | <2mA |
| Data Record | Yes |
| Battery Included | No |
| High-concerned chemical | None |
| Alarm Reminder | Built-in flashing lights, audible alarms |
Product Dimensions
- Waterproof model: 68.5 * 38.5 * 14.1 mm
- Non-waterproof model: 73.78 * 43.8 * 14 mm
- Non-waterproof model opening size: 68.78 * 38.8 mm
3. Setup
3.1 Wiring
The voltmeter uses a simple two-wire connection. Connect the red wire to the positive (+) terminal of your DC power source (8-100V) and the black wire to the negative (-) terminal. Ensure proper polarity to avoid damage to the device.
3.2 Mounting Options
The unit comes with fixings for two mounting options: a main bracket and a cast aluminum handlebar clamp. Choose the option that best suits your application.
4. Operating Instructions
On the home screen, the device displays real-time voltage, battery percentage, and temperature. The single button on the device serves multiple functions:
- Short Press: To turn the display on and off.
- Long Press (2 seconds): To activate the SET key and enter the configuration mode.
5. Mode Setting Instructions
To enter the settings menu, long-press the button for 2 seconds from the main page. Once in the settings, short-press the button to cycle through different setting pages (menus).
5.1 Ternary Lithium Battery Settings (Menu 1)
- From the main page, long-press the button for 2 seconds to enter settings. The display will show "L-003" (default for 3 strings).
- On the "L-003" page, long-press the button for 2 seconds; the value "03" will flash.
- Short-press the button to select the desired number of battery strings (from 03 to 22).
- After selecting, long-press the button for 2 seconds to confirm (the value will stop flashing).
- Long-press the button again for 2 seconds to return to the main page, or short-press to go to the next setting page.
5.2 Iron-Lithium Battery Settings (Menu 2)
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the "F-003" page (default for 3 strings of iron-lithium batteries).
- On the "F-003" page, long-press the button for 2 seconds; the value "03" will flash.
- Short-press the button to select the desired number of battery strings (from 03 to 26).
- After selecting, long-press the button for 2 seconds to confirm (the value will stop flashing).
- Long-press the button again for 2 seconds to return to the main page, or short-press to go to the next setting page.
5.3 Lead-Acid Battery Settings (Menu 3)
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the "P-12" page (default for 12V lead-acid battery).
- On the "P-12" page, long-press the button for 2 seconds; the value "12" will flash.
- Short-press the button to select the desired battery voltage (12V, 24V, 36V, 48V, 60V, 72V, or 84V).
- After selecting, long-press the button for 2 seconds to confirm (the value will stop flashing).
- Long-press the button again for 2 seconds to return to the main page, or short-press to go to the next setting page.
5.4 Custom Voltage Settings (Menu 4)
This setting allows you to define custom high and low voltage alarm thresholds (8V DC to 100V) with power-off memory.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the custom voltage setting page (indicated by "C-" and voltage values). The high voltage value is on the left, and the low voltage value is on the right.
- Long-press the button for 2 seconds; the first value (high voltage) will flash.
- Short-press the button to select the desired high voltage value.
- Long-press the button for 2 seconds to confirm the high voltage value; the second value (low voltage) will then flash.
- Short-press the button to select the desired low voltage value.
- After both values are set, short-press the button to enter the second line of the setting page (if applicable).
- Long-press the button for 2 seconds to return to the main page, or short-press to go to the next setting page.
5.5 Backlight Settings (Menu 5)
This function allows you to adjust the backlight duration.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the "bL" page.
- On the "bL" page, long-press the button for 2 seconds; the number "00" will flash.
- Short-press the button to select the desired backlight duration: 00 (always on), 10, 20, 30, 40, 50, 60, 70, 80, or 90 seconds.
- After selecting, long-press the button for 2 seconds to confirm (the value will stop flashing).
- Long-press the button again for 2 seconds to return to the main page, or short-press to go to the next setting page.
5.6 High and Low Pressure Alarm Settings (Menu 6)
This function sets the high and low voltage alarm thresholds.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the high and low pressure alarm function settings page (indicated by "AL" and voltage values). The left value is the high pressure (voltage) value, and the right is the low pressure (voltage) value.
- Long-press the button for 2 seconds; the first value (high voltage) will flash.
- Briefly press the button to select the desired high voltage value.
- Hold the button for 2 seconds until the first value is solid and the second value (low voltage) is flashing.
- Briefly press the button to select the desired low voltage value.
- Once both values are set, briefly press the button to enter the setup page on the right.
- Briefly press the button for 2 seconds to return to the main page, or briefly press to go to the next setup page.
5.7 Voltage Calibration Setting (Menu 7)
Warning: This function is for advanced users only. Unauthorized operation will affect the voltage accuracy. Please contact the manufacturer for assistance if needed.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the electronic calibration ("CL") page.
- On the "CL" page, long-press the button for 2 seconds; "88.8" will flash.
- Long-press the button again for 2 seconds to complete the automatic calibration and return to the main page.
5.8 SOC Mode Setting (Menu 8)
Warning: This function is not user-configurable. Please contact the manufacturer for details.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the SOC ("SO") settings page.
- On the "SO" page, long-press the button for 2 seconds to select "ON" or "OF" on the right.
- Long-press for 2 seconds to confirm.
- Long-press for 2 seconds to return to the main page, or short-press to go to the next page.
5.9 Restore Factory Settings (Menu 9)
Warning: Non-professionals should not use this function, as it may affect the product's functionality.
- From the main page, long-press the button for 2 seconds to enter settings.
- Short-press the button until you reach the Factory Reset ("FR") page.
- On this page, long-press the button for 2 seconds. The three "8"s on the left will flash, then turn into three "0"s.
- Long-press the button again for 2 seconds to restore the factory settings. The three "0"s will remain lit continuously, indicating that the reset is complete.
- Long-press the button for 2 seconds to return to the main page.
6. Maintenance
- Keep the device clean and dry. Use a soft, dry cloth to wipe the display and casing.
- Avoid exposing the device to extreme temperatures, direct sunlight, or corrosive environments.
- Ensure all connections are secure and free from corrosion.
- While the product may feature waterproof technology, it is advisable to protect it from prolonged exposure to water or submersion.
7. Troubleshooting
If you encounter issues with your voltmeter, consider the following:
- Inaccurate Measurement: If you suspect inaccurate readings, refer to the Voltage Calibration Setting (Menu 7). Note that this function is not recommended for non-professionals and incorrect calibration can worsen accuracy. Contact the manufacturer if the issue persists.
- Display Issues (e.g., power outage, no display): Check the wiring connections to ensure they are secure and correctly polarized. Verify that the power source is within the DC 8-100V range.
- Configuration Difficulty: The device is programmable for different battery types, voltages, and backlight settings. If you are having trouble configuring it, carefully follow the step-by-step instructions in Section 5. For complex settings like SOC mode, it is recommended to contact the manufacturer.
- Battery Not Full/Low Battery Warnings: The device is designed to provide warnings for overcharge and over-discharge. Ensure your battery type and voltage settings are correctly configured to match your battery.
8. User Tips
- Easy Installation: The two-wire installation makes this unit straightforward to set up.
- Versatile Mounting: Utilize the provided main bracket or the cast aluminum handlebar clamp for flexible mounting options depending on your application.
- Programmability: Take advantage of the device's programmability for various battery types, voltages, and backlight settings to customize it to your specific needs.
- Robust Build: The unit features a robust construction with painted steel and a cast aluminum clamp, ensuring durability.
9. Warranty and Support
For detailed warranty information, technical support, or to access the full user manual in PDF format, please refer to the official product documentation or contact the manufacturer directly. The user manual (PDF) can be referenced at: User Manual (PDF).