Moes PTH-24D

Contents

Moes 3-in-1/4-in-1 Carbon Monoxide and Combustible Gas Detector User Manual

Model: PTH-24D

1. Introduction

Thank you for choosing the Moes 3-in-1/4-in-1 Carbon Monoxide and Combustible Gas Detector. This device is designed to provide continuous monitoring of carbon monoxide (CO) and combustible gas levels, along with temperature and humidity, to ensure the safety of your home environment. Please read this manual carefully before use and keep it for future reference.

Moes 4-in-1 CO Detector with temperature and humidity display
Figure 1: Moes 4-in-1 CO Detector with temperature and humidity display.

2. Safety Information

Your safety is paramount. This device is an important tool for detecting potential hazards, but it is not a substitute for proper ventilation and maintenance of fuel-burning appliances. Always follow local safety codes and regulations.

2.1 Carbon Monoxide (CO) Hazards

Carbon monoxide is a colorless, odorless, and tasteless gas that can be fatal. Symptoms of CO poisoning can include:

  • Headache
  • Palpitations
  • Dizziness
  • Nausea
  • Coma
  • Organ damage

2.2 Combustible Gas Hazards

Combustible gases (such as natural gas, propane, methane) can cause explosions or suffocation. Symptoms of combustible gas exposure can include:

  • Gas leak odor (if odorized)
  • Suffocation
Diagram illustrating symptoms of Carbon Monoxide and Combustible Gas hazards
Figure 2: Potential hazards of Carbon Monoxide and Combustible Gas.

In case of an alarm, immediately ventilate the area, evacuate all occupants, and contact emergency services.

3. Product Overview

The detector features a clear display and intuitive controls. It integrates multiple sensors for comprehensive environmental monitoring.

3.1 Components and Display

Diagram showing front and back views of the detector with labeled parts: CO Unit, Gas Sensitivity, Temp Value, CO Value, Gas Level, Hum Value, Alert Icon, Sound, Disassembling Button, Plug, Ventilation, Model Information.
Figure 3: Front and back view of the detector with labeled components.
  • CO Unit (PPM): Displays Carbon Monoxide concentration in parts per million.
  • Gas Sensitivity (S1): Indicates the detected combustible gas level.
  • Temp Value: Shows the current ambient temperature.
  • Hum Value: Displays the current ambient humidity.
  • Alert Icon: Visual indicator for alarms.
  • Sound Icon: Indicates alarm sound status.
  • Disassembling Button: Used for plug replacement (for 4-in-1 models).
  • Plug: For direct wall outlet connection.
  • Ventilation: Air inlets/outlets for sensor operation.
  • Model Information: Located on the back, includes product model (PTH-24D), input voltage (100-220V 50/60Hz), and certifications (CE, RoHS, FC).

3.2 Sensor Technology

The detector utilizes high-precision sensors for accurate readings:

  • Catalytic Combustion Sensor: For detecting combustible gases.
  • Electrochemical Sensor: For detecting carbon monoxide.
Exploded view of the detector showing the Catalytic Combustion Sensor and Electrochemical Sensor
Figure 4: Internal view highlighting the high-precision sensors.

4. Specifications

Feature Specification
Model PTH-24D
Gas Type Detection Carbon Monoxide (CO), Combustible Gas (e.g., CO2 mentioned in properties, but typically natural gas/propane for combustible gas detectors)
Additional Features Temperature, Humidity
Display LCD Screen
Power Source Plug-in (100-220V 50/60Hz)
Battery Included No
Dimensions (approx.) 105mm (H) x 52mm (W) x 55mm (D)
Certifications CE, RoHS, FC
Diagram showing the dimensions of the detector: 105mm/4.13in height, 52mm/2.05in width, 55mm/2.17in depth.
Figure 5: Detector dimensions.

5. Setup

5.1 Unpacking

Carefully remove the detector from its packaging. Inspect the device for any signs of damage. If damaged, do not use and contact customer support.

5.2 Placement

For optimal performance and safety, place the detector in areas where CO or combustible gas leaks are most likely to occur, such as near fuel-burning appliances (furnaces, water heaters, gas stoves) or in living areas. Ensure it is plugged into a standard wall outlet.

  • Avoid placing near windows, doors, or ventilation openings that could dilute gas concentrations.
  • Avoid placing in direct sunlight or areas with extreme temperature fluctuations.
  • Ensure the ventilation slots are not obstructed.

5.3 Powering On (Plug & Play)

The detector is designed for plug-and-play operation. Simply insert the device into a suitable wall outlet. The device will automatically power on and begin its self-test sequence.

Image showing the detector being plugged into a wall outlet, demonstrating its plug-and-play functionality.
Figure 6: Plug-and-play setup.

5.4 Plug Replacement (4-in-1 models)

For 4-in-1 models, the plug can be disassembled and replaced to suit different regional outlets (e.g., EU, UK, US). To replace, press the disassembling button, twist the plug, and replace with the desired type.

Front and back view of the 3-in-1 EU Plug version of the detector.
Figure 7: Example of an EU plug variant.

6. Operating Instructions

Once plugged in, the detector will display real-time readings for CO, gas levels, temperature, and humidity.

Video 1: Product demonstration showing alarm activation, plug-and-play setup, brightness adjustment, screen rotation, and CO detection.

6.1 Key Functions

Diagram illustrating key functions: Long press to switch temperature unit, short press for self-test, screen brightness keys (100%, 50%, 0% brightness), long press to flip screen 180 degrees, short press to unmute/sound off.
Figure 8: Key functions of the detector.
  • Switching Temperature Unit: Long press the 'U' button to toggle between Celsius (°C) and Fahrenheit (°F).
  • Self-test: Short press the 'U' button to initiate a self-test.
  • Screen Brightness Adjustment: Use the brightness keys (light bulb icon) to cycle through three levels: 100% brightness (First Gear), 50% brightness (Second Gear), and 0% brightness (Breathing Light is turned off).
  • Screen Rotation: Long press the screen rotation button (circular arrow icon) to flip the display 180 degrees. This is useful if your outlet orientation requires the device to be upside down.
  • Sound On/Off: Short press the bell icon button to toggle the alarm sound on or off.

6.2 Alarm Levels and Indicators

The detector provides visual and audible alarms based on detected CO and combustible gas levels:

Diagram showing 4 levels of visual and audible alarms for CO and Gas: Safety (0-50PPM CO, Lv1<5% LFL Gas, Green light, No audible alarm), Attention (51-100PPM CO, 5%<Lv2<8% LFL Gas, Yellow light flashes slowly, audible alarm), Warning (101-150PPM CO, 8%<Lv3<15% LFL Gas, Orange light flashes fast, audible alarm), Danger (150-999PPM CO, Lv4>=15% LFL Gas, Red light flashes fast, audible alarm).
Figure 9: Alarm levels for CO and Combustible Gas.
Level CO Concentration (PPM) Combustible Gas (LFL) Visual Indicator Audible Alarm
Safety 0-50 PPM Lv1 < 5% LFL Green indicator light No audible alarm
Attention 51-100 PPM 5% < Lv2 < 8% LFL Yellow indicator light flashes slowly Audible alarm
Warning 101-150 PPM 8% < Lv3 < 15% LFL Orange indicator light flashes fast Fast audible alarm
Danger 150-999 PPM Lv4 ≥ 15% LFL Red indicator light flashes fast Fast audible alarm

Always take immediate action when an alarm sounds.

7. Maintenance

Regular maintenance ensures the longevity and accuracy of your detector.

7.1 Cleaning

  • Wipe the exterior of the detector with a soft, damp cloth.
  • Do not use harsh chemicals, cleaning solvents, or abrasive cleaners.
  • Ensure the ventilation openings are free from dust and debris. Use a soft brush or vacuum cleaner to gently clear them.

7.2 Self-Test

Perform the self-test function (short press 'U' button) regularly, at least once a month, to confirm the device is operating correctly.

7.3 Sensor Life

Gas sensors have a limited lifespan. While not user-replaceable, be aware that the detector's effectiveness may diminish over time. Consider replacing the unit after 5-7 years of continuous operation, or as recommended by the manufacturer.

8. Troubleshooting

If you encounter issues with your detector, refer to the following common problems and solutions:

Problem Possible Cause Solution
No display/Device not powering on No power from outlet; device malfunction Check the power outlet with another appliance. If still no power, contact support.
False alarms Interference from aerosols, strong fumes, or high humidity Relocate the detector away from sources of interference. Ensure proper ventilation.
Alarm sounds without apparent gas Low-level gas presence; sensor fault Ventilate the area. Perform a self-test. If alarms persist, treat as a real alarm and evacuate.
Display shows 'Err' or similar error code Internal fault Unplug the device for 1 minute and plug it back in. If the error persists, contact customer support.

9. User Tips

  • Optimal Placement: For best results, plug the detector into an outlet that is not obstructed by furniture and is within the recommended height range for gas detection (e.g., closer to the floor for heavier-than-air gases like propane, higher for lighter-than-air gases like natural gas, and at breathing level for CO).
  • Regular Testing: Make it a habit to press the self-test button monthly to ensure the alarm and sensors are functioning.
  • Screen Rotation: Utilize the screen rotation feature if your wall outlet orientation makes the display difficult to read.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the seller directly. A detailed user manual in PDF format may also be available for download from the manufacturer's website or via the provided link: User manual (PDF).

© 2024 Moes. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.