1. Product Overview
The Voktta T700-2 is a compact and portable liquefied petroleum gas (LPG) alarm equipped with a high-sensitivity sensor. It continuously monitors the concentration of LPG and other combustible gases in the environment in real-time. When gas concentrations exceed preset safety thresholds, the device triggers a high-decibel alarm, providing timely early warning, explosion prevention, and poisoning prevention. This device serves as a crucial safety tool for both household and industrial settings.
Its lightweight design, ease of operation, and practical functionality make it ideal for various applications, including outdoor use.

Figure 1: Device highlighting its rapid response time of 0.5-2 seconds for precise detection.

Figure 2: Device illustrating its wide range of applications in various industries and domestic settings.
2. Safety Information
- Do not expose the device to extreme temperatures or direct sunlight.
- Keep the device away from water and high humidity.
- Do not attempt to open or repair the device yourself; refer to qualified personnel.
- Ensure the detection port is clear of obstructions for accurate readings.
- This device is an alarm and not a substitute for proper ventilation or professional safety measures.
3. Package Contents
- Voktta T700-2 Combustible Gas Detector x 1
- USB Type-C Charging Cable x 1
- Lanyard x 1
- Instruction Manual x 1

Figure 3: The gas detector, USB-C charging cable, and lanyard included in the package.
4. Product Components

Figure 4: Labeled diagram of the Voktta T700-2 showing its main components.
- Lanyard: For easy carrying and attachment.
- Switch (Power On/Off): To turn the device on or off.
- Indicator Light: Displays device status (preheating, alarm, charging).
- Type-C Charging Port: For connecting the USB charging cable.
- Horn Opening: Where the buzzer alarm sound is emitted.
- Liquid and Gas Detection Port: The sensor inlet for detecting gases.
5. Setup
5.1 Initial Charging
- Connect the provided USB Type-C charging cable to the device's charging port.
- Plug the other end of the USB cable into a standard USB power adapter (not included) or a computer USB port.
- During charging, the red indicator light will flash.
- The device is fully charged when the green indicator light flashes.
5.2 Attaching the Lanyard
Thread the lanyard through the designated loop on the device for convenient carrying.
6. Operating Instructions
6.1 Powering On and Preheating
- Push the switch upward to turn on the alarm.
- The indicator lights will illuminate in sequence: red → blue → green.
- Once the green light is steadily on, the preheating process is complete. This takes approximately 30 seconds. The device is now ready for use.
6.2 Gas Detection and Alarm
- The device continuously monitors the surrounding air for combustible gases.
- If the combustible gas concentration in the air is below 50 ppm, the device will not alarm.
- If the combustible gas concentration exceeds 50 ppm, the device will trigger an immediate buzzer alarm.
- The higher the gas concentration, the faster the frequency of the buzzer alarm, providing a stronger warning.

Figure 5: The gas detector providing an ultra-fast response and pinpoint detection with a buzzer alarm.

Figure 6: The device offers dual detection for indoor combustible gas and carbon monoxide.
6.3 Automatic Power-off
The device features an automatic shut-off function. If no operation is detected within 5 minutes, the device will power off automatically to conserve energy.
7. Maintenance
7.1 Cleaning
- Wipe the device with a soft, dry cloth.
- Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the device.
- Ensure the gas detection port is kept clean and free from dust or debris.
7.2 Battery Care
- Recharge the device when the battery is low to ensure continuous operation.
- Use only the provided USB Type-C cable for charging.
- Avoid overcharging or completely draining the battery for extended periods to prolong its lifespan.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on | Low battery; Device not switched on | Charge the device; Ensure the switch is pushed upward |
| Alarm sounds continuously without gas presence | Sensor obstruction; High humidity; Sensor malfunction | Clean detection port; Move to a drier area; Contact support |
| Device does not detect gas | Detection port blocked; Gas concentration too low; Sensor malfunction | Clear obstruction; Ensure gas concentration is above 50ppm; Contact support |
| Indicator lights not working | Device off; Malfunction | Turn on device; Contact support |
9. Specifications

Figure 7: Detailed product specifications for the Voktta T700-2.
| Parameter | Detail |
|---|---|
| Product Name | Combustible Gas Leak Detector |
| Model | T700-2 |
| Sensor Type | Semiconductor |
| Sensor Warm-up Time | 30 seconds |
| Detection Range | 50-1000 ppm (methane) |
| Response Sensitivity | <50 ppm (methane) |
| Alarm Mode | Buzzer alarm (frequency varies with gas concentration) |
| Applicable Gases | Flammable gases, Methane, Natural gas, LPG, Carbon Monoxide (CO), Ethane (C2H6), Propane (C3H8), Ethylene (C2H4), Propylene (C3H6), Acetylene (C2H2), Propyne (C3H4) |
| Operating Environment | 0~50°C / 32~122°F |
| Storage Environment | -10~60°C / 14~140°F |
| Power Supply | Built-in 3.7V Lithium Battery |
| Response Time | 0.5s-2s |
| Auto Power-off Time | 5 minutes (if no operation) |
10. User Tips
- Always ensure the device is fully charged before critical use.
- Regularly check the detection port for any obstructions to ensure accurate readings.
- Familiarize yourself with the alarm sound and its varying frequencies to understand the severity of a gas leak.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.