1. Introduction
Thank you for choosing the KING SMART 2.1 Gallon Water Heater Safety Tank. This thermal expansion tank is designed to protect your water heater and plumbing system from excessive pressure caused by thermal expansion of water during heating cycles. It helps maintain a safe and efficient operation of your hot water system.
2. Safety Information
Please read all safety warnings and instructions carefully before installation or use. Failure to follow these instructions may result in property damage, serious injury, or death.
- Pressure Relief Valve: A pressure relief valve, sized and installed according to local codes, must be incorporated in systems requiring a combined temperature and pressure safety relief valve. Never plug a safety relief valve.
- Pre-Charge Adjustment: DO NOT adjust the air pre-charge of the expansion tank with the system under pressure. The air pre-charge should only be adjusted under zero system pressure. The normal pre-charge is 20 psi. DO NOT exceed 80 psi (5.5 bar).
- Maximum Pressure & Temperature: This Expansion Tank is designed for water storage at a maximum pressure of 150 psi (10.3 bar) and a maximum temperature of 200°F (93ºC). Any use exceeding these limits is unsafe and can cause property damage, serious bodily injury, or death.
- Qualified Personnel: Only qualified personnel may install or service this equipment in accordance with local codes and ordinances.
- Leakage: All expansion tanks may leak over time. Do not install without adequate drainage provisions. Select a location where a water leak will not damage the surrounding area.
3. Product Overview & Components
The KING SMART thermal expansion tank is constructed with durable materials to ensure long-lasting performance and safety.

Key Components:
- Sealed Air Valve (H68): For adjusting the tank's pre-charge pressure.
- Clasp (ST12): Secures internal components.
- Liner (PP): 100% pressure tested for reliability.
- Tank Body (ST12): Durable outer shell.
- Membrane (Butyl Rubber): Flexible diaphragm that separates air from water.
- O-ring (Butyl): Provides a watertight seal.
- Connector (Stainless Steel): 3/4" MNPT connector with hex for plumbing connection.
4. Specifications

| Feature | Specification |
|---|---|
| Capacity | 2.1 Gallons (7.95 Liters) |
| Dimensions (H x W) | 11.81" x 7.48" (approx. 30cm x 19cm) |
| Connection Size | 3/4" MNPT (Male National Pipe Taper) |
| Factory Pre-charge | 40 PSI |
| Max. Working Pressure | 150 PSI |
| Max. Operating Temperature | 210°F (99°C) |
| Material | Carbon Steel |
| Certifications | CUPC, NSF/ANSI/CAN 61, Low Lead Certified |
5. Setup & Installation
For detailed installation instructions and diagrams, please refer to the official user manual PDF: View User Manual (PDF)
5.1. Prior to Installation
- Determine System Pressure:
- Open a faucet to allow the system pressure to balance.
- Close faucet and read the system pressure at the pressure gauge.
- Pre-charge Expansion Tank: Pre-charge the expansion tank to the same system pressure identified in step 1. The normal pre-charge is 20 psi. Do not exceed 80 psi.
- Unscrew the protective cap from the air inlet valve.
- Using a tire pressure gauge, check the tank pre-charge pressure.
- If necessary, pressurize the tank to the proper setting using a manual bicycle tire pump. Do not exceed 80 psi.
- Replace the protective air cap.
5.2. To Install Tank
- Shut off water supply valve and power source to the water heater.
- Drain system following water heater manufacturer specifications.
- Install the expansion tank in the system either vertically (preferred method) or horizontally. Note that the tank must be properly supported in horizontal applications.
- The weight of the expansion tank is supported by the system piping, so ensure piping has suitable bracing as needed (strapping, brackets, hanging, etc.).
- All expansion tanks may leak over time. Do not install without adequate drainage provisions.
- Turn on water supply valve.
- Open a faucet (use hot water side) and allow water to flow until all air is removed from the system.
- Turn on power source to water heater.
- Open a faucet (use hot water side) to allow slight flow until the hot water has reached operating temperature.
- Recheck system pressure as noted above in prior to installation section.


6. Operation
In a closed hot water system, as water is heated, it expands. Since water is incompressible, this expansion can lead to a significant increase in pressure within the plumbing system, potentially damaging pipes, fixtures, and the water heater itself. The KING SMART thermal expansion tank absorbs this expanded water volume. The tank's internal butyl rubber membrane flexes to accommodate the extra water, preventing pressure from exceeding safe limits and protecting your system.
7. Maintenance
- Annual Pressure Check: Annually, check the tank's air pre-charge pressure (when the system is depressurized) to ensure it matches your system's static cold water pressure.
- Inspect for Leaks: Periodically inspect the tank and its connections for any signs of water leaks or corrosion.
- Visual Inspection: Check the tank for any physical damage or excessive rust.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| High water pressure in system | Incorrect tank pre-charge, tank failure (waterlogged), or tank is undersized. | Verify and adjust pre-charge. If waterlogged, replace tank. Consult a professional for sizing. |
| Water leaking from tank body or connections | Loose connections, damaged tank body, or internal diaphragm failure. | Tighten connections. If tank body is damaged or diaphragm failed, replace the tank. |
| Water coming out of air valve when pressed | Internal diaphragm has failed. | Replace the expansion tank. |
9. User Tips
- Match Pre-charge: Always ensure the tank's pre-charge pressure matches your system's static cold water pressure for optimal performance.
- Accessible Installation: Install the tank in a location that is easily accessible for future maintenance and inspection.
- Check Local Codes: Always consult and adhere to local plumbing codes and regulations for installation.
10. Frequently Asked Questions (FAQ)
- Q: What is the primary purpose of a thermal expansion tank?
- A: Its primary purpose is to absorb the expanded volume of water that occurs when water is heated in a closed plumbing system, preventing excessive pressure buildup.
- Q: How often should I check the air pressure in my expansion tank?
- A: It is recommended to check the air pre-charge pressure annually, ensuring it matches your system's static cold water pressure.
- Q: What does it mean if water comes out of the air valve when I press it?
- A: This indicates that the internal diaphragm has failed, and the tank has become waterlogged. The expansion tank needs to be replaced.
11. Warranty & Support
This KING SMART 2.1 Gallon Water Heater Safety Tank comes with a 6-year warranty from the date of purchase, covering defects in materials and workmanship.
For warranty claims, technical support, or any questions regarding your product, please contact the seller or manufacturer directly.
Product Display Video: A visual overview of the KING SMART 2.1 Gallon Water Heater Safety Tank.