1. Product Overview
Thank you for choosing the Aninerel GD series MPPT controller. This new generation MPPT controller is designed with the latest technology, representing the forefront of photovoltaic technology development. It offers several excellent performances:
- Excellent heat dissipation design with an intelligent control cooling fan.
- Innovative Maximum Power Point Tracking (MPPT) technology significantly improves the energy utilization efficiency of solar energy systems, achieving a conversion efficiency of up to 97%.
- Quickly scans the entire I-V curve to track the maximum power point in just a few seconds.
- Supports three types of lead-acid batteries (sealed, colloidal, and open type) and lithium battery series charging programs.
- Automatic protection functions for overcharging, over-discharging, overload, and short circuit.
- RS485 communication interface for multi-machine communication, with a distance of up to 1km, allowing communication with a computer for convenient monitoring of operating parameters.


The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array for battery charging. This method is fully automatic and does not require user adjustment. When the maximum power point of the array changes due to environmental conditions, the controller automatically tracks it to ensure maximum energy harvest from the solar array.
If the maximum power point voltage (Vmp) of the solar array is greater than the battery voltage, the charging current of the battery will be proportionally greater than the output current of the solar array, balancing input and output power. This current enhancement is crucial in systems where the Vmp of solar panels is typically higher than the battery voltage.
Compared to traditional controllers, MPPT controllers offer significant advantages, especially in hot weather where Vmp might be close to or even lower than the battery voltage. By optimizing the charging process, MPPT controllers ensure efficient energy acquisition and reduce wiring current, saving on costs.
2. Safety Instructions
WARNING: Please read all instructions and warnings in this manual before installing and operating the controller. Keep this manual for future reference.
- High Voltage Risk: The input voltage range of this controller is large. Incorrect operation may cause personal injury. All work on the charging controller must be carried out by technical personnel.
- Restricted Use: This device is not intended for use by children or individuals with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the device by a person responsible for their safety. Keep away from children.
- Hot Components: The controller's shell components can reach high temperatures. Do not touch the controller with your hands after opening the casing during operation.
- Installation Environment: Install in an environment with good heat dissipation and ventilation.
- Radiation: Do not stay near solar charging controllers for extended periods (less than 20 centimeters) as radiation can harm health.
- Input DC Voltage: Ensure the input DC voltage does not exceed the specified maximum voltage. Exceeding this limit may cause permanent damage and void the warranty.
- Maintenance: If technicians need to maintain or clean solar controllers or connect them to circuits, they must follow relevant safety steps.
- Circuit Breakers: To disconnect the solar panel array, use a circuit breaker and prevent accidental activation. Disconnect the circuit breaker and ensure it cannot be reconnected. Verify no voltage is present in the system.
- Overvoltage Protection: Overvoltage can damage the system. Thunderstorms and lightning increase the risk of damage; consider external overvoltage protection systems.
- Wiring: Ensure existing lines are in good condition and suitable wire sizes are used. Do not operate if the solar controller is damaged or wiring is not qualified.
- Disassembly: Do not disassemble or attempt to repair the solar charging controller yourself, as this may result in further damage, accidents, and void the warranty.
- Flammable Materials: Keep away from flammable and explosive materials.
- Environment: Install away from damp or corrosive substances.
- Short Circuits: Use insulated tools when operating equipment to avoid short circuits.

3. Installation
Installation must be completed by professional technicians.
3.1 Selection of Installation Location
- Install on a solid surface.
- The installation location must be accessible at all times and allow for easy removal.
- The ambient temperature should be between -20°C and +40°C for optimal working environment.
- Do not install the charging controller in direct sunlight to avoid power loss due to overheating.
3.2 Safety Distance
Observe the following safety clearances to ensure adequate heat dissipation space around the controller:
| Description | Safe Distance |
|---|---|
| Side | 20 CM |
| Top | 30 CM |
| Bottom | 30 CM |
3.3 MPPT Controller Connection
The controller can be used for off-grid solar modules of 12V, 24V, and 48V, as well as grid-connected modules with an open circuit voltage not exceeding the specified maximum input voltage. The voltage of the solar modules in the system should not be lower than the system voltage.
WARNING: Electric shock hazard! Photovoltaic modules may generate high voltage. Be careful to prevent electric shock when wiring.
ATTENTION: Connecting photovoltaic modules must be done with the circuit breaker disconnected.
3.3.1 Wiring Steps
WARNING: Short circuits between the positive and negative terminals of the battery and connected wires can pose a risk of fire or explosion. Handle with caution.


3.3.2 Cable and Circuit Breaker Specifications
| Model | GD-50A | GD-60A | GD-80A | GD-100A | GD-120A |
|---|---|---|---|---|---|
| Cable (copper) | 10mm² | 16mm² | 16mm² | 25mm² | 25mm² |
| Circuit breaker | 63A | 80A | 100A | 125A | 125A |
3.3.3 Battery Connection
ATTENTION: Connecting the battery pack must be done with the circuit breaker disconnected.
3.3.4 DC Load Connection
The load terminal of the controller "DC LOAD" can be connected to DC electrical equipment with the same rated working voltage as the rated voltage of the battery. The controller supplies power to the load based on the battery voltage.
3.3.5 Power On Trial Operation
ATTENTION: Before powering on for trial operation, please check that all DC connection wires have their positive and negative poles fully connected correctly.
- Check that the positive and negative terminals of the connecting wire are fully connected correctly.
- Measure the open circuit voltage of the photovoltaic module to ensure it is within the working range of the controller.
- First, turn on the circuit breaker connecting the controller to the battery.
- Then, open the circuit breaker connecting the controller to the solar panel.
- The controller will begin to enter self-test mode. If system conditions are correct, it will automatically enter working mode. If incorrect, a fault prompt will be displayed.
- The battery type controller defaults to maintenance-free lead-acid batteries at the factory. Refer to the battery type settings for adjustments.
4. Operating Instructions

4.1 Panel Component Description
| Number | Name | Number | Name |
|---|---|---|---|
| 1 | LCD display screen | 5 | Junction box cover plate |
| 2 | Charging indicator light | 6 | Flip up button |
| 3 | Function menu button | 7 | Confirm button |
| 4 | Flip down button | 8 | DC output indicator light |
4.2 Indicator Light Status Description
| Name | State | Status Description |
|---|---|---|
| Charge indicator | Flash mob | Charging in maximum power tracking mode |
| Slow flashing | Floating charging mode charging | |
| Extinguish | Stop charging | |
| DC output indicator light | Bright | Normal output |
| Dodge | Battery undervoltage prompt | |
| Extinguish | Turn off output |
4.3 LCD Display Screen Description
4.3.1 Main Interface
The LCD displays various parameters. The default main interface shows real-time data. Press the DOWN or UP key to scroll through the screen and view different parameters.

4.3.2 Main Menu Navigation
From the default main interface, press the MENU key to enter the main menu. Use the DOWN or UP key to navigate through submenus. Press ENTER to select an option.
- Run parameter settings
- Time and date settings
- Contrast setting
- Brightness setting
- Sound settings
- Record query
- Clear Record
- DC output setting
- Communication settings
- Language settings
4.3.3 Operating Parameter Settings
ATTENTION: Setting operating parameters must be done by professional technicians. Incorrect operation may cause malfunction or damage to the battery.
To access parameter settings: From the main interface, press MENU, select 'Run parameter settings' with DOWN, then press ENTER. Enter the password, then press ENTER again to access the settings.
Before setting parameters, ensure the circuit breaker connected to the photovoltaic module and MPPT controller is set with correct parameters including battery type, rated voltage, charging voltage, and lower limit of K-discharge. Confirm compliance before opening the photovoltaic module circuit breaker.
Battery Type Settings
In the parameter interface, press ENTER to enter battery type settings. Use DOWN to select the battery type (lead-acid maintenance free, gel battery, liquid battery, lithium battery series), then press ENTER to confirm. A continuous prompt sound will confirm the setting. Press MENU to return to the upper layer.
The factory default is maintenance-free lead-acid batteries.
Rated Battery Voltage Setting
In the parameter interface, press DOWN to select rated voltage setting, then ENTER. Select the rated voltage level (automatic recognition, 12V, 24V, 36V, 48V...) with DOWN, then ENTER to confirm. A continuous prompt sound will confirm. Press MENU to return to the upper layer.
The factory default automatically identifies the rated voltage level for lead-acid batteries. Lithium battery series are not automatically recognized. Manual setting of voltage level is required for lithium batteries or to customize charging/discharge limits.
Charging Voltage Setting
- Choose your battery type (lead-acid or lithium).
- Set the rated battery voltage level (e.g., 12V, 24V, 36V, 48V, 72V, 96V...).
- Understand and follow the charging parameters recommended by your battery manufacturer.
Note: Lithium battery series only use float charging (constant voltage) mode. Even charging mode is only for lead-acid batteries.
To set: In the parameter interface, select 'charging voltage setting' with DOWN, then ENTER. Use UP/DOWN to adjust values, then ENTER to confirm and save. Press MENU to return.
Charging Current Setting
In the parameter interface, select 'charging current setting' with DOWN, then ENTER. Use UP/DOWN to adjust the value, then ENTER to confirm and save. Press MENU to return.
The set value cannot exceed the current maximum value.
Discharge Limit Setting
This sets the cut-off voltage and resumption voltage of the DC output.
In the parameter interface, select 'discharge limit setting' with DOWN, then ENTER. Use UP/DOWN to adjust values, then ENTER to confirm and save. Press MENU to return.
Factory Reset
In the parameter interface, select 'restore factory settings' with DOWN, then ENTER. Select whether to restore with DOWN, then ENTER to confirm. Press MENU to return.
If the MPPT controller malfunctions due to incorrect parameter settings, restoring factory settings can resolve the issue.
Password
To enter running parameter settings, press DOWN key 3 times, then UP key 3 times, and then ENTER.
5. Technical Specifications
The Aninerel MPPT Solar Charge Controller is available in 60A, 80A, and 100A models, supporting 12V, 24V, 36V, and 48V battery systems. Below are the detailed technical parameters for each model.
General Specifications
| Attribute | Description |
|---|---|
| Charge Mode | MPPT automatic maximum power point tracking |
| Charging Method | Three stages: constant current (MPPT), balanced charging, and float charging |
| System Type | 12V-24V/12V-48V Automatic recognition/manual setting |
| Soft Start Time | ≤10s |
| Dynamic Response Recovery Time | ≤500us |
| Static Power Consumption | ≤2W |
| Efficiency | ≥ 96.5% |
| Utilization Rate of Photovoltaic Modules | ≤99.97% |
| LCD Display | Refer to LCD display instructions for details |
| LED Display | Charging indicator, DC output switch status indicator |
| PC Upper Computer (Communication Port) | RS485 (optional) |
| Mechanical Protection Type | IP21 |
| Humidity | 0~90% RH (no condensation) |
| Altitude | 0~3000m |
| Ambient Temperature | -20°C ~ +40°C |
| Storage Temperature | -40°C ~ +70°C |
| Atmospheric Pressure | 70~106kPa |
| Audio Noise | <50dB |
| Heat Dissipation Method | Forced air cooling, fan speed adjusted by temperature. Fan runs slowly or stops when internal temperature is low or controller stops working. |
| Element Quality | Imported materials complying with EU standards, electrolytic capacitors rated for temperature not less than 105°C. |
| Odor | No odor or harmful to health |
| Environmental Requirements | Meets 2002/95/EC; No cadmium, hydrides, and fluorides. |
5.1 60A Model (ANL-MPPT-48V-60A)

5.2 80A Model (ANL-MPPT-48V-80A)

5.3 100A Model (ANL-MPPT-48V-100A)

5.4 Dimensions

6. Troubleshooting
If the controller encounters an abnormality, refer to the table below for common issues and their solutions. If the problem persists, contact customer service.
| Abnormal Phenomenon of Malfunction | Relieve the Malfunction |
|---|---|
| MPPT controller powers on for the first time, and the fault prompt is: battery voltage exceeds the normal recognition range. |
|
| Fault prompt: Over temperature protection |
|
| Fault prompt: Battery overdischarge protection | The battery has run out of energy. |
| Fault prompt: No external temperature sensor detected | Ensure the temperature sensor is correctly connected. |
| The charging indicator light is not on and there is no charging current or charging power display. |
|
| The charging indicator light lights up briefly and then goes out quickly, and the charging current is sometimes intermittent. | This usually occurs on cloudy days or in the evening when there is insufficient sunlight, which is a normal phenomenon. |
| No power curve and current curve display. | Check if the time and date displayed on the MPPT controller are correct (refer to time and date settings). |
If the problem still persists after following the above table, please contact customer service personnel. Provide the following information: equipment information (model, order number, serial number from the back panel); detailed description of the problem (system type used, occasional or frequent occurrence, indicator lights, display status, etc.).
7. Maintenance and Cleaning
7.1 Replacing Fuses
If a fuse burns out due to high temperature or other malfunctions, it must be replaced correctly. Remove the broken fuse from the interface, install a new fuse, check for correct connection, and then reinstall the device. The fuse is located near the wiring junction.
7.2 Cleaning Ventilation Vents and Heat Sinks
Regularly clean the fan vents and internal heat sinks by wiping them with a dry or slightly damp cloth. Do not use detergent or corrosive solvents for cleaning. Prevent liquid from flowing into the machine. Ensure the ventilation holes are not blocked.
8. User Tips
- Optimal Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to optimize charging efficiency.
- Regular Checks: Periodically check all wiring connections for tightness and corrosion to prevent power loss and ensure safety.
- Monitor Display: Pay attention to the LCD display for any fault codes or unusual readings, which can indicate potential issues early.
- Battery Compatibility: Always verify that your battery type and voltage settings in the controller match your actual battery bank to prevent damage and ensure proper charging.
- Environmental Considerations: While the controller is robust, protecting it from direct harsh weather conditions (like heavy rain or extreme dust) can extend its lifespan.
9. Quality Assurance and Support
9.1 Quality Assurance
Products that malfunction during the quality assurance period will be repaired or replaced with new products free of charge by our company.
Evidence for Warranty Claim
During the warranty period, customers are required to provide invoices and dates of purchase. The product's trademark must be clearly visible; otherwise, the right to quality assurance may be denied.
Conditions for Replacement/Repair
- The replacement of non-conconforming products will be handled by our company.
- Customers should allow reasonable maintenance time for equipment repair.
Warranty Exclusions
Our company reserves the right to deny quality assurance in the following situations:
- The entire machine and components have exceeded the free warranty period.
- Damage caused during transport.
- Incorrect installation or modification for use.
- Operating in extremely harsh environments beyond those described in this manual.
- Machine malfunctions or damages caused by non-company service agencies, unauthorized repairs, modifications, or dismantling.
- Damage caused by abnormal natural environment.
If a product malfunction is caused by any of the above situations, and the customer requests repair services, our service agency can provide paid maintenance services after determination.
9.2 Additional Resources
A detailed user manual in PDF format is available for download. This document provides comprehensive instructions and specifications. You can access it via the following link: Aninerel MPPT Solar Charge Controller User Manual (PDF)
The size and parameters of the product may change based on the latest information provided by our company without prior notice.