1. Introduction
Welcome to your Toviyon DC regulated power supply. This manual contains essential safety instructions that must be followed for the operation, use, and storage environment of this product series. To ensure your personal safety, please thoroughly read this manual before operation to avoid personal injury due to improper handling or damage to the power supply and other connected load equipment.
The TPA series is a digital display programmable switching DC regulated power supply that can simultaneously display voltage, current, and power. This power supply is widely used in product aging, battery charging, R&D testing, schools, and production lines. Its output voltage and current are both adjustable via an encode knob, continuously adjustable between 0 and the nominal value.
The power supply has excellent stability and ripple coefficient, and features multiple protection circuits including short-circuit protection, overvoltage protection, overcurrent protection, and overtemperature protection. The product boasts an attractive design, user-friendly operation, and the ability to work at full capacity for extended periods. It is equipped with a USB fast charging interface and offers optional PC software control functionality, making it a popular choice among users.
2. Safety Summary
The following safety symbols may appear in the manual or on the machine:
- ⚠ Warning Label: Indicates potential hazards.
- ⚠ High Volt Danger: Indicates presence of high voltage.
- ⊥ Grounding: Indicates the need for proper grounding.
- 🗑 Do Not Litter: Dispose of responsibly.
- ✅ Certification Mark (CE): Product conforms to European safety standards.
- 🏠 Indoor Use: Product is intended for indoor use only.
Incorrect AC voltage input will cause serious damage to the machine. Please ensure that the machine requires the correct input voltage.
3. Setup
3.1 AC Input
Please verify the AC voltage input permitted for this machine. Refer to the label information located near the power outlet on the back of the machine.
- 230V ±10% 50Hz
- 115V +10% 60Hz
3.2 Connect the Ground Wire
When using this product, please ensure the power cord is properly grounded. If the power outlet does not have a ground wire, you can use a wire to connect the machine's grounding terminal to the earth. Proper grounding can effectively prevent machine leakage and reduce output ripple interference.
3.3 Connect the Load Device
- Securely connect the output wires to the power supply terminals according to the positive (+) and negative (-) markings.
- Securely connect the other end of the output lead to the positive and negative terminals of your load device.
Incorrect connections may damage the power supply and the load connected to it. When connecting loads such as batteries, do not reverse the "+" and "-" terminals, as this may damage the power supply.
3.4 Front Panel Introduction
Familiarize yourself with the controls and indicators on the front panel:
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Voltage Display | 12 | Short-Circuit/Overcurrent Protection Switch (OCP) |
| 2 | Current Display | 13 | Over Voltage Protection Switch (OVP) |
| 3 | Power Display | 14 | Buzzer Switch |
| 4 | C.V (Constant Voltage Indicator Light) | 15 | Output Switch |
| 5 | M1-M4 Storage Indicator Light | 16 | USB-A Fast Charging Port |
| 6 | C.C (Constant Current Indicator Light) | 17 | USB-C Fast Charging Port |
| 7 | OPN Indicator Light | 18 | Power Switch |
| 8 | Current adjustment knob | 19 | Negative Output Port (Black) |
| 9 | Voltage Adjustment Knob | 20 | Ground Terminal (Green) |
| 10 | Button Lock Switch | 21 | Positive Output Port (Red) |
| 11 | Storage Selection/Value Setting Switch |
3.5 Back Side Description
| No. | Component |
|---|---|
| 22 | Temp-Controlled Cooling Fan |
| 23 | Power Outlet |
| 24 | Fuse Box |
| 25 | USB/RS-232/RS-485 Communication Port (Optional) |
4. Operating Instructions
4.1 Constant Voltage (C.V) and Constant Current (C.C) Mode
The power supply output modes are divided into two types: constant voltage output (C.V) and constant current output (C.C). The output mode is determined by the voltage and current values set by the user and the load connected to the power supply. The voltage or current value output by the power supply will not exceed the voltage and current values set by the user. In constant voltage mode, the output voltage is equal to the user-set voltage value. In constant current mode, the output current is equal to the user-set current value.
During actual C.V operation, if the load resistance decreases and causes the output current to increase to the set current value, the power supply will automatically switch to C.C mode. When the load resistance continues to decrease, the current will remain at the set current value while the voltage proportionally decreases (I=V/R). At this point, increasing the load resistance or raising the current set value will restore the C.V output mode.
4.2 Voltage Adjustment Knob
Used to adjust the voltage setting. Rotate clockwise to increase the value; rotate counterclockwise to decrease the value. Pressing the voltage knob will jump to the left, skipping a character position. After 3 seconds, the flashing will stop and the current setting value will be saved.
4.3 Current Adjustment Knob
Used to adjust the current setting. Rotate clockwise to increase the value; rotate counterclockwise to decrease the value. Pressing the current knob will jump to the left. The flashing will stop 3 seconds after the current setting is complete, and the current setting will be saved.
4.4 Button Lock Switch (LOCK)
Used to lock the state of the push-button switches (excluding the power switch and LOCK button lock switch) and adjustment knobs on the front panel to prevent accidental operation.
Video 1: Demonstration of stable voltage under full load, memory function, lock function, mute, and dual USB charging.
4.5 Memory Storage Group Selection/Storage Value Setting
This machine has four sets of memory functions (M1-M4), which makes it easy to store and recall frequently used parameters.
- Storage Group Selection: Press the MEMORY button to select any one of the four preset voltage/current storage values. The selection result can be confirmed through the display screen and the M1~M4 storage indicator lights.
- Stored Value Settings: To change a stored value (e.g., M2), press the MEMORY button to select M2. Then, press and hold the MEMORY button for 3 seconds to enter the parameter setting interface (you will hear two "beep" sounds). Use the VOLTAGE/CURRENT knob to adjust to the desired voltage/current value. After modification, press and hold the MEMORY button for 3 seconds within 8 seconds to save (you will hear two "beep" sounds). If not saved within 8 seconds, the interface will exit without saving.
4.6 OCP (Short-Circuit Protection/Overcurrent Protection) Switch
Press the OCP button to enable/disable the OCP function. When enabled, the button indicator light will illuminate. If a short circuit or overcurrent occurs, the machine will stop output and issue an alarm. Pressing the OUTPUT button or the OCP button will deactivate the alarm and shut off the power output. (Note: The machine determines a short circuit by checking if the output current exceeds the user-set current. Therefore, OCP cannot be used in constant current (C.C) mode.)
OCP Parameter Setting Method: Press and hold the OCP button for 3 seconds (two "beep" sounds). Use the CURRENT knob to adjust the desired current protection value. After modification, press and hold the OCP button for 3 seconds within 8 seconds to save (two "beep" sounds). If not saved within 8 seconds, settings will exit without saving.
4.7 OVP (Over Voltage Protection) Switch
Press the OVP button to enable/disable the OVP function. When enabled, the button light will illuminate. When an overvoltage occurs, the machine will stop outputting and issue an alarm. Pressing the OUTPUT button or the OVP button will deactivate the alarm and turn off the power output.
OVP Parameter Setting Method: Press and hold the OVP button for 3 seconds (two "beep" sounds). Use the VOLTAGE knob to adjust the desired voltage protection value. After modification, press and hold the OVP button for 3 seconds within 8 seconds to save (two "beep" sounds). If not saved within 8 seconds, settings will exit without saving.
4.8 Buzzer Switch
Press the
button to turn the buzzer on or off.
4.9 OUTPUT Switch
Press the OUTPUT button to turn the power output on or off.
4.10 OPN Function
The OPN function controls whether the OUTPUT button is ON or OFF each time the device is powered on.
How to enable/disable the OPN function: With the OUTPUT button OFF, press and hold the OUTPUT button for 3 seconds to enter the settings interface (you will hear two "beep" sounds). Press the OUTPUT button or rotate the VOLTAGE/CURRENT knob to select whether the OPN function is on or off. After making your selection, press and hold the OUTPUT button for 3 seconds to save and exit (you will hear two "beep" sounds).
4.11 USB Fast Charging Function
This device features USB fast charging and has a built-in multi-protocol fast charging identification chip, with a maximum output power of 18W.
4.12 Host Computer Communication (Optional)
Users can choose models equipped with USB / RS-232 / RS485 communication modules to communicate with a host computer via the MODBUS protocol, enabling remote control.
5. Maintenance
5.1 Regular Inspection, Cleaning, and Maintenance
Regular maintenance can help extend the lifespan of your machine. Please follow these steps:
- Turn off the power switch and unplug the power cord from the socket.
- Gently wipe the casing, top cover, and vents with a soft cloth and mild detergent.
- Visually inspect all power cords and terminals for damage such as impact, loosening, heat corrosion, moisture, or insect bites. Replace any damaged power cords or terminals with those of the same specifications and dimensions.
5.2 Replace Fuse
If the fuse blows, the machine will stop working. Find and correct the cause of the blown fuse before replacing it with a fuse of the same specifications.
For effective safety protection, only fuses of specific specifications should be replaced. Do not unplug the power cord before replacing the fuse.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on / No signs of life | Power cord not connected, power switch off, blown fuse. | Ensure power cord is securely plugged into both the unit and the wall outlet. Check if the power switch is ON. Inspect and replace the fuse if blown (refer to Section 5.2). |
| No output voltage/current | Output switch OFF, OCP/OVP activated, incorrect settings. | Press the OUTPUT button to turn on output. Check if OCP or OVP indicator lights are on; if so, deactivate the alarm by pressing OUTPUT or the respective protection button. Verify voltage and current settings. |
| OCP/OVP alarm sounds | Overcurrent or overvoltage condition detected. | Identify and resolve the cause of the overcurrent/overvoltage in your load. Press the OUTPUT button or the OCP/OVP button to clear the alarm and reset output. Adjust OCP/OVP limits if necessary (refer to Sections 4.6 and 4.7). |
| Inaccurate readings | Loose connections, faulty cables, environmental factors. | Ensure all connections are secure. Use high-quality output cables. Verify ambient temperature and humidity are within specified operating ranges. |
7. Specifications
7.1 Machine Parameter Table
| Parameter | TPA305 | TPA3010 | TPA605 | TPA1203 | TPA1602 |
|---|---|---|---|---|---|
| Output Voltage | 0-30V | 0-30V | 0-60V | 0-120V | 0-160V |
| Output Current | 0-5A | 0-10A | 0-5A | 0-3A | 0-2A |
| Output Power | 0-150W | 0-300W | 0-300W | 0-360W | 0-320W |
| Fuse | 3.15A | 5A | 5A | 5A | 5A |
| Accessibility | Dual fast charging ports, short circuit protection, four storage groups, lock function, buzzer, one-button output. | ||||
| C.V Voltage Stability | ≤0.5% +3mV | ||||
| C.V Load Stability | ≤0.5% +3mV | ||||
| C.V Ripple | ≤0.5% Vp-p | ||||
| C.C Current Stability | ≤0.5% +3mA | ||||
| C.C Load Stability | ≤0.5% +3mA | ||||
| C.C Ripple | ≤0.5% Ap-p | ||||
| Product Dimensions | Length 214mm, Width 90mm, Height 156mm | ||||
| Product Weight | Net weight: 1.17 kg. Gross weight: 1.55 kg. | ||||
| Operating Temperature | 0 °C ~ 40 °C, Relative humidity: <80%RH | ||||
| Storage Temperature | -10 °C ~ 50 °C, Relative humidity: <70%RH | ||||
| Protection Method | Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Short Circuit Protection | ||||
| Display Accuracy | 0.5% + 3 words | ||||
| Maximum Resolution | Volt: 0.001V; Current: 0.001A | ||||
The above parameters were measured at an ambient temperature of 25±5°C, relative humidity <80%RH, and after preheating for 30 minutes. Actual parameters may vary slightly.
7.2 Additional Specifications
- Input Power Supply: AC 230V/115V ± 10%; 50Hz/60Hz
- Material: Galvanized
- Recovery Time: ≤ 500 μs
- Temperature Coefficient: ≤ 100ppm/°C
8. Warranty & Support
8.1 Product Inspection
Each product comes with an instruction manual and a certificate of conformity to ensure that users can use our products correctly. All products manufactured and inspected by our company are produced and inspected according to the manufacturer's standards; any unqualified products will never leave the factory.
8.2 Product Warranty
A one-year warranty is provided, excluding damage caused by human error.
8.3 Product Repair
Free repair or replacement of parts is provided during the warranty period. After the warranty period, paid repair services are available. During the product's service life, if the product malfunctions, the company is only responsible for the malfunction and loss of the product itself; the company does not bear any load or other related losses.
Guarantee Limitations: The following warranties do not apply to losses caused by the following circumstances:
- Customer violation of the usage instructions in this manual
- Customer disassembly or repair of the product
- Unauthorized modifications or misuse
- Operation of the product outside the specified environment
- Force majeure factors under relevant laws
8.4 Packing List
- Main unit x1
- Power cord x1
- Output load cable x1
- User manual x1
- Warranty card and certificate of conformity x1
8.5 Contact Information
Shenzhen Toviyon Electronics Technology Co., Ltd.
Address: Room 203, 2nd Floor, No. 69, Langkou Industrial Park, Langkou Community, Dalang Subdistrict, Longhua District, Shenzhen
Web: www.toviyon.com
Tel: (+86)18588483965
WhatsApp: +1(424)413-3536
WeChat: 18588483965
9. User Tips
- Initial Power-On Check: If the unit does not power on or shows no signs of life, first ensure the power cord is securely connected to both the unit and a working wall outlet. Then, check the fuse as described in the 'Maintenance' section (Section 5.2) and replace it if necessary.
- Stable Output: For critical applications, always verify the output voltage with an external multimeter, especially under full load, to ensure stability.
- Memory Presets: Utilize the 4 memory groups (M1-M4) to quickly recall frequently used voltage and current settings, saving time during repetitive tasks.
- Protection Features: Always enable OCP and OVP when working with sensitive circuits or during experimental setups to prevent damage to both the power supply and your connected devices.