1. Introduction
The YSRSAI DA1-T is a versatile LED controller designed for constant voltage LED strip lights. It supports multiple dimming protocols including DALI, 0/1-10V, and Triac dimming, offering flexible control options for various lighting setups. This device features a single channel with a maximum output of 8A, DALI-2 certification, and built-in protection mechanisms for safe and reliable operation.
Key features include:
- DALI + 0/1-10V + Triac dimming constant voltage LED controller with 1 channel, maximum 8A output.
- DALI-2 certified, in accordance with DALI standard protocol IEC 62386-101, 102, 207, and compliant with DALI products from other international corporations.
- DALI addresses can be manually assigned via DIP switch or automatically assigned by the DALI master.
- The DALI signal input port supports triac dimming and AC auto-reset switch dimming.
- Compatible with active or passive 0-10V, 1-10V dimmers.
- PWM frequency 2KHz or 8KHz selectable.
- Standard DALI logarithmic dimming curve.
- Over-heat / Over-load / Short circuit protection, with automatic recovery.
2. Specifications
| Category | Parameter | Value |
|---|---|---|
| Input and Output | Input Voltage | 12-36VDC |
| Max Input Current | 8A | |
| Output Voltage | 12-36VDC | |
| Output Current | 8A @12/24V, 6A @36V | |
| Output Power | 96W @12V, 192W @24V, 216W @36V | |
| Output Type | Constant Voltage | |
| Dimming Data | Input Signal | DALI + 0/1-10V + Triac + AC push switch |
| Dimming Range | 0-100% | |
| PWM Frequency | 2KHz (default), 8KHz selectable | |
| Environment | Operation Temperature | -20°C ~ +55°C |
| Case Temperature (Max) | Tc +78°C | |
| Material | ABS | |
| Safety and EMC | EMC Standard | EN IEC 55015, EN IEC 61547 |
| Safety Standard | EN 61347-1/-2 | |
| Certification | CE, RoHS, DALI-2 | |
| Warranty | 1 Year | |
| Package | Size | L160 x W60 x H32mm |
| Gross Weight | 0.040kg |
3. Setup and Installation
3.1 Mechanical Structure
The DA1-T controller features mounting tabs on both sides that can be snapped off along the scored lines to accommodate different installation requirements.
3.2 Wiring Diagrams
Safety Warning: DO NOT install with power applied to the device. Ensure all power is disconnected before making any wiring connections.
3.2.1 Connect with DALI Master
3.2.2 Connect with Push Switch
3.2.3 Connect with Triac Dimmer
The DA1-T supports connection with Triac dimmers, both with and without a neutral wire input. Ensure DIP switch 8 is set correctly to select the dimming input method.
3.2.4 Connect with 0/1-10V Dimmer
Note for 0/1-10V Input:
- The 0/1-10V input is operable via commercially available simple rotary wall switches designed for 0/1-10V dimming equipment or from dedicated system central dimming controllers.
- Compliant with 0-10V, 1-10V, 10V PWM, RX(4 in 1).
- It is recommended that the number of LED dimming controllers connected to a 0/1-10V dimmer does not exceed 50 pieces, and the maximum length of the wires from the dimmer to the LED driver should be no more than 50 meters.
- If the LED dimming controller is used with a Push-Dim interface prior to using the 0/1-10V interface, the 0/1-10V signal should change over 10% to return 0/1-10V control.
- Push switch (Push) and triac dimmer (Triac) inputs cannot be connected simultaneously. Please first use DIP switch 8 to select the dimming input method.
4. Operating Instructions
4.1 Push Dim Function
The self-reset switch interface can be connected to a self-reset panel switch or a self-reset button to dim the light.
- Short press: Turn on or off the light.
- Long press (1-6s): Press and hold for stepless dimming. With every other long press, the light level goes in the opposite direction.
- Synchronization: If more than one controller is connected to the same push switch, perform a long press for more than 10 seconds. The system will synchronize, and all lights in the group will dim up to 100%.
4.2 DALI Address Setting
DALI addresses can be set manually using DIP switches 1-6 or automatically assigned by the DALI master.
4.2.1 Manual DALI Address Assignment (DIP Switches 1-6)
The DALI address (0-63) is calculated as: (1 x dip1 + 2 x dip2 + 4 x dip3 + 8 x dip4 + 16 x dip5 + 32 x dip6). Refer to the table below for specific address settings. 'ON' corresponds to the DIP switch being in the ON position, and 'OFF' corresponds to the OFF position.
4.2.2 Automatic DALI Address Assignment
DALI addresses can also be automatically assigned by the DALI master. Refer to the DALI master user manual for instructions on this process.
4.3 PWM Frequency Setting
Set the PWM frequency using DIP switch 7. The factory default PWM frequency is 2KHz. A higher PWM frequency will result in lower output current and higher power noise, but is more suitable for camera use (no flickers for video).
| PWM Frequency | Output Current (Iout) | |
|---|---|---|
| Uin | 2KHz | 8KHz |
| 12-24V | 8A | 6A |
| 36V | 6A | 5A |
4.4 Set Button Function
4.4.1 Restore Factory Defaults
Press and hold the SET button for 10 seconds. The LED indicator will fast flash 6 times, restoring the device to factory default settings. Factory default parameters are: DALI dimming mode, DALI address not assigned, and open-circuit detection disabled.
4.4.2 Open-Circuit Detection
When the light is off, press the SET button 5 times in quick succession to enable or disable the open-circuit detection function.
- If the LED indicator flashes 3 times, the open-circuit detection function is enabled.
- If the LED indicator flashes 5 times, the open-circuit detection function is disabled.
5. Maintenance
The YSRSAI DA1-T dimmer is designed for low maintenance. To ensure optimal performance and longevity:
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- DO NOT expose the device to moisture or extreme temperatures outside its specified operating range (-20°C to +55°C).
- Ensure proper ventilation around the device to prevent overheating.
- Regularly check wiring connections for any signs of wear or looseness.
6. Troubleshooting
If you encounter issues with your DA1-T dimmer, consider the following:
- No Light Output:
- Check all power connections to ensure they are secure and receiving the correct voltage (12-36VDC).
- Verify the LED strip is correctly connected to the LED OUT terminals.
- Ensure the dimming input (DALI, 0/1-10V, Triac, Push) is correctly wired and functioning.
- Check if the open-circuit detection is enabled and if it's indicating an issue (LED indicator flashes 3 times).
- Incorrect Dimming Behavior:
- For DALI, verify the DALI address is correctly set via DIP switches or assigned by the DALI master.
- For 0/1-10V, ensure the dimmer is compatible and wired correctly. If switching from Push-Dim, ensure the signal changes by more than 10%.
- For Push-Dim, check the duration of the press for short (on/off) vs. long (stepless dimming) actions.
- Ensure DIP switch 8 is correctly set for the chosen dimming input method (Push or Triac).
- Overheating/Protection Triggered:
- Reduce the load if it exceeds the maximum output current (8A for 12-24V, 6A for 36V).
- Ensure adequate ventilation around the device.
- Check for short circuits in the LED strip or wiring. The device has automatic recovery from over-heat/over-load/short circuit.
- Device Not Responding:
- Try restoring factory defaults by pressing and holding the SET button for 10 seconds.
6.1 Safety & Warnings
- DO NOT install with power applied to the device.
- DO NOT expose the device to moisture.
- Cannot be connected to both the DALI master and the push switch simultaneously, as this will burn out the DALI bus power supply.
7. User Tips
- For flicker-free video recording with your LED lights, consider setting the PWM frequency to 8KHz using DIP switch 7, although this may slightly reduce the maximum output current.
- When integrating into a DALI system, it's often easier to let the DALI master automatically assign addresses rather than manually configuring DIP switches, especially for multiple devices.
- Always double-check your wiring against the provided diagrams before applying power to prevent damage to the device or connected components.
8. Warranty and Support
The YSRSAI DA1-T DALI + 0/1-10V Triac Dimmer comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.
For further technical assistance or detailed documentation, you may refer to the official user manual PDF available online. A comprehensive PDF version of this manual can be found at: YSRSAI DA1-T User Manual (PDF).