1. Introduction
The ANENG A3015 is a smart pen-style electrical tool designed for comprehensive electrical testing and measurement. It combines the functions of a multimeter with a portable, ergonomic design, making it ideal for both professional electricians and DIY enthusiasts. Featuring a 4000-count high-definition digital display, the A3015 offers a range of capabilities including NCV (Non-Contact Voltage) detection, AC/DC voltage measurement, resistance testing, phase sequence detection, and live/neutral line identification. Its compact size and integrated features prioritize both safety and convenience for on-site inspections and household circuit troubleshooting.
Key Features:
- Multi-functional Real-time Detection: AC/DC voltage, resistance, on-off (continuity), phase sequence, and data hold.
- NCV Non-Contact Voltage Induction: Detects AC voltage without direct contact, with high and low sensitivity modes.
- Live/Naught Line Detection: Differentiates between live and neutral wires.
- Line Breakpoint Lookup: Helps locate breaks in electrical lines.
- High Definition LCD Backlit Screen: Ensures clear readings in various lighting conditions.
- LED Lighting Function: Provides illumination for working in dark environments.
- Automatic Shutdown: Conserves battery life by automatically turning off after 15 minutes of inactivity.
- Durable Metal Probe: High-quality, wear-resistant probe for long service life.
2. Safety Information
WARNING: To avoid possible accidents such as electric shock or personal injury, please read this manual carefully and strictly adhere to all instructions. Failure to do so may damage or weaken the protective functions provided by the instrument.
- Always follow local and national safety regulations for measurements. Wear appropriate personal protective equipment (e.g., approved rubber gloves, masks, and flame-retardant clothing) to protect against electric shock and arcing when working with dangerous live conductors.
- Exercise extreme caution when measuring voltages exceeding 60V DC or 36V AC. These voltage levels pose a significant risk of electric shock.
- Do not measure voltages higher than the rated value specified for the instrument, either between terminals or between terminals and ground.
- Before each use, verify the instrument's proper functioning by measuring a known voltage. If the device appears abnormal or damaged, do not use it.
- Inspect the instrument's casing for cracks or damaged plastic parts before use. If any damage is found, do not use the device.
- Use the meter in accordance with the measurement category and voltage rating specified in this manual or on the meter itself.
- If the low battery indicator appears, replace or charge the battery promptly to prevent inaccurate measurements.
- Do not use the instrument in environments with explosive gases, steam, or high humidity.
- Never use the meter when it is disassembled or when the battery cover is open.
- When measuring high voltages, avoid touching the tip of the pen or any metal part of the pen to prevent electric shock.
3. Product Overview
The ANENG A3015 pen multimeter features a clear LCD display and intuitive button layout for ease of use. Understanding its components and functions is crucial for effective operation.
Function Buttons:
- Power Button (␦): Long press for 2 seconds to turn the device on or off. Short press to toggle the backlight on or off.
- SEL Button: Short press to switch between DC voltage, AC voltage, resistance, and phase sequence measurement modes.
- H/L LIVE Button: Short press to toggle between NCV low and high sensitivity, and LIVE functions.
- HOLD Button: Short press to lock the displayed data.
Main Components:
- Positive input/Nib probe
- LCD high definition backlight display
- Data hold key (HOLD)
- H/L LIVE key (High/Low sensitivity, Live line detection)
- Function switch key (SEL)
- Power button (␦)
- COM jack: Black pen input/negative terminal
4. Specifications
The following table details the technical indicators and general characteristics of the ANENG A3015 Multimeter. All parameters are for reference only, and actual measurements may vary slightly.
General Characteristics:
- Display: 3999-bit LCD display
- Operating Mode: Manual Range
- Automatic Shutdown: After 15 minutes of no operation
- Power Supply: 2 x 1.5V AAA batteries (A3015 model, not included)
- Safety Level: IEC61010-1, CAT III 600V
- Material: ABS/stainless steel
- Dimensions: 177 x 28 x 26 mm (L x W x H)
- Weight: Approximately 58g (without battery)
Electrical Technical Indicators:
| Function | Range | Resolution | Precision |
|---|---|---|---|
| DC Voltage | 4V~600V | 0.001V~1V | ±(0.1%+2d) |
| AC Voltage (40Hz-1KHz) | 4V~600V | 0.001V~1V | ±(1.2%+3d) |
| Resistance | 4KΩ~40MΩ | 0.001KΩ~0.01MΩ | ±(2.0%+5d) |
| On/Off (Continuity) | If resistance < 50Ω, buzzer sounds and backlight turns bright red. | ||
| Phase Sequence Detection | ✓ | Data retention | ✓ |
| Naught/Live Line | ✓ | Low power prompt | ✓ |
| NCV Voltage Induction | ✓ | Battery type | 1.5V AAA battery * 2 (Not included) |
| Line Breakpoint Lookup | ✓ | Automatic Shutdown | After 15 min of no operation |
| High/Low Sensitivity | ✓ | Maximum Count | 4000 count |
| High Definition Backlight Screen | ✓ | Material | ABS/stainless steel |
| Low Power Prompt | ✓ | Weight | 58g (without battery) |
Note: The parameters are for reference only, and the actual measurement of the specific equipment shall prevail.
5. Setup
5.1 Replacing the Battery
The ANENG A3015 (battery model) requires 2x 1.5V AAA batteries (not included). When the battery low indicator (⚠) appears on the LCD, the batteries must be replaced to ensure accurate operation.
- Unplug any connected test leads and turn off the instrument.
- Use a screwdriver to open the battery cover on the back of the device.
- Remove the old batteries and insert two new 1.5V AAA batteries, ensuring correct polarity.
- Securely close the battery cover.
Note: The A3016 is a charging model. For the A3015, only battery replacement is applicable.
6. Operating Modes
The ANENG A3015 offers both automatic and manual measurement modes for various electrical parameters.
6.1 Automatic Measurement Mode
- Upon power-on, the display shows "Auto", indicating intelligent measurement mode. In this mode, the device can automatically measure DC voltage, AC voltage, on-off (continuity), and resistance.
- Connect the black test pen to the "COM" input jack.
- Use the test pen (nib) and the black pen to measure the voltage, continuity, or resistance of the circuit under test. Connect them in parallel with the circuit.
- Read the measurement value from the liquid crystal display. When measuring DC voltage, the display will also show the voltage polarity connected to the positive input.
6.2 Manual Measurement Mode
- Upon power-on, the display shows "Auto". Short press the SEL button to cycle and switch between DC voltage, AC voltage, resistance, and phase sequence measurement modes.
- Connect the black test pen to the "COM" input jack.
- Read the measurement value from the liquid crystal display. When measuring DC voltage, the display will also show the voltage polarity connected to the positive input.
6.3 DC Voltage Measurement
- Connect the instrument nib and the black test pen to the power supply or load to be tested. The polarity of the nib's end will be displayed on the screen.
- The display will show the measured DC voltage.
- The minimum voltage automatically recognized is 0.8V. Voltages below 0.8V cannot be measured in auto mode. To measure lower voltages, press the SEL button to manually switch to DCV measurement.
Attention: Do not input voltages higher than 600V, as this may damage the internal wiring of the meter. When measuring high voltages, do not touch the tip of the pen or any metal part of the pen to avoid electric shock.
6.4 AC Voltage Measurement
- Connect the instrument nib and the black test pen to the power supply or load to be tested.
- The display will show the AC voltage measurement.
- The minimum voltage automatically recognized is 0.8V. Voltages below 0.8V cannot be measured in auto mode. To measure lower voltages, press the SEL button to manually switch to ACV measurement.
Attention: Do not input voltages higher than 600V, as this may damage the internal wiring of the meter. When measuring high voltages, do not touch the tip of the pen or any metal part of the pen to avoid electric shock.
6.5 Resistance Measurement
- Connect the instrument nib and the black test pen to the tested resistance.
- The display will show the resistance measurement value.
Note: If the measured resistance value exceeds the maximum range, the display will show "OL". When checking online resistance, ensure all power supplies in the measured line are turned off and all capacitors are fully discharged.
6.6 On-Off (Continuity) Measurement
- Connect the black test pen to the "COM" jack.
- Connect the instrument nib and the black test pen to two points of the circuit under test.
- If the resistance between the two points is less than approximately 50Ω, the built-in buzzer will sound, and the display screen will show the conduction resistance value.
Attention: The line under test must be checked with the power cut off. Charging the line will cause the instrument to make an incorrect judgment and may seriously damage the instrument.
6.7 Non-Contact Electric Field (NCV) Measurement
- Short press the H/L LIVE button to select the NCV mode; the display will show "NCV".
- Bring the instrument nib close to the measured object (approximately 8-15mm) for induction detection.
- AC voltage intensity is divided into two levels:
- Weak/Medium Electric Field: Display shows "---", the buzzer emits intermittent beeps, and the green backlight flashes.
- Strongest Electric Field: Display shows "----", the buzzer emits continuous beeps, and the red backlight flashes.
- Short press the H/L LIVE button to toggle between NCV low and high sensitivity.
Attention: When switching the range for NCV measurement, please unplug the black test pen to avoid electric shock.
6.8 Firewire (Live Line) Measurement
- Short press the H/L LIVE button to select the Live file measurement; the display will show "Live".
- When the instrument nib touches a live wire, the red LED light will turn on, and the LCD screen will display "----H" with a beep.
- If the pen is connected to a neutral line, the buzzer will not sound, and the LCD screen will display "Live" without a beep.
6.9 Phase Sequence Detection
- Short press the SEL button to switch to Phase gear.
- Touch the instrument nib to any line (A, B, or C) of the three-phase electricity. Wait until the letter "A" on the display screen stops flashing and the buzzer emits a beep.
- The display will then show the letter "B" flashing. Touch the nib to the second line of the three-phase electricity. Once "B" stops flashing and the buzzer beeps, the display will show "C" flashing.
- Touch the nib to the third line. Once "C" stops flashing, the phase sequence is determined to be positive.
6.10 Line Breakpoint Lookup
The A3015 can help locate breakpoints in electrical lines using NCV mode. Where the alarm sound is strong, the line is smooth and good. The weak signal indicates the position where the line is disconnected.
7. Maintenance
7.1 Cleaning
To clean the surface of the instrument, use a soft, dry cloth. Do not use organic solvents that may corrode or dissolve the casing material.
Attention: If the parameters in this manual are changed without prior notice, the company will not be responsible for accidents or hazards caused by user error.
8. Troubleshooting
8.1 Product Not Operating Properly
If you encounter issues with the product not operating as expected, please provide a detailed video demonstrating the problem to ANENG customer service. This will help our experts diagnose the issue and provide a timely solution.
8.2 Questions About Product Use
This product is a technical instrument that requires a certain degree of electrical knowledge. If you encounter operational problems or need assistance with how to use the product, please contact ANENG customer service for support.
8.3 Artificially Damaged Product
The ANENG A3015 is primarily used to detect electrical and other measurement products. It requires careful operation and adherence to correct measurement methods to avoid dangerous events. If the product is used improperly or in a way that results in damage, it will be considered man-made damage and may not be covered under warranty. However, you may still contact ANENG customer service to inquire about a discount on purchasing new ANENG products.
9. User Tips
No specific user tips from reviews or Q&A were provided for this manual. Always refer to the safety guidelines and operating instructions for optimal performance and safety.
10. Accessories List
The following items are included in the product package:
- Packaging box * 1
- Instruction manual * 1
- Pen Multimeter (ANENG A3015) * 1
- Spring test pen line * 1
- Spring clip * 1
- Philips screwdriver * 1
11. Warranty and Support
ANENG is committed to providing excellent after-sales service. For any questions or concerns regarding your ANENG A3015 Intelligent Multimeter, please contact our customer service team.
Contact for After-Sales Questions:
If you have any questions during the use of the product, please contact ANENG customer service. Our customer service team will provide you with satisfactory solutions in a timely manner.
About Quality Issues:
In case of quality problems other than "man-made damage" during the use of this product, replacement service or refunds can be provided. For specific product damage, please contact ANENG customer service to confirm and discuss solutions.
- Replacement Method: Replacement of spare parts, or replacement of the whole machine.
- Refund Method: Partial refund according to damaged parts, or full refund if the whole machine is returned.
Replacement or Refund Request:
To initiate a replacement or refund request:
- Contact customer service and provide a video demonstrating the product quality problem for damage determination.
- Negotiate a solution.
- For damaged products with quality problems, avoid secondary damage.
- Execute the solution as agreed.