1. Safety Information
This manual contains important safety information. Please read it carefully before using the instrument and pay special attention to all warnings and cautions.
1.1. Safety Statement
In accordance with international copyright law, the contents of this manual may not be copied in any form without permission and written consent. The manual is subject to change in future editions without prior notice.
1.2. Safety Instructions
The instrument is designed according to the requirements of the international electrical safety standard IEC61010-1 for electronic testing instruments. The design and manufacture strictly comply with IEC61010-1 CAT.III 600V over-voltage safety standards and pollution level 2.
- Read this manual carefully before use and pay special attention to safety warnings.
- Strictly observe the operation instructions. Failure to do so may damage the instrument or weaken its protection function.
- Be careful if the measurement exceeds 30V AC true RMS, 42V AC peak, or 60V DC, as there may be a danger of electric shock.
- Before use, measure a known voltage to check if the meter is working normally. If it is not normal or damaged, do not use it again.
- Before use, check for any cracks or plastic damage in the instrument case. If found, do not use it.
- Before use, check if the probe is cracked or damaged. If so, replace it with the same type and electrical specifications.
- The instrument must be used in accordance with the specified measurement category, voltage, or current rating.
- Comply with local and national safety codes. Wear personal protective equipment (e.g., approved rubber gloves, masks, flame retardant clothes) to prevent electric shock and electric arc from exposed hazardous live conductors.
- If the low battery indicator is displayed, replace the battery promptly to avoid measurement errors.
- Do not use the instrument around explosive gas, steam, or in a wet environment.
- When using the probe, keep your fingers behind the finger protector.
- When measuring, connect the zero line or ground line first, then the live wire. When disconnecting, disconnect the live wire first, then the zero line and ground line.
- Before opening the outer cabinet or battery cover, remove the probe from the instrument. Do not use the instrument if it is taken apart or the battery cover is open.
- The instrument meets safety standards only when used with the supplied probe. If the probe is damaged, a replacement probe with the same model number and electrical specifications must be used.
1.3. Safety Symbols
| Symbol | Description |
|---|---|
| ⚡ | High voltage warning |
| ∼ | AC (Alternating current) |
| ——— —— |
DC (Direct current) |
| ∼ ——— —— |
AC or DC |
| ⚠ | Warning, important safety signs |
| ⟘ | Ground |
| ⊖ | Fuse |
| □□ | Double insulation/reinforced insulation |
| 🔋 | Low battery voltage |
| CE | Product complies with all relevant European laws |
| ☠ | Do not discard this electrical/electronic product into household garbage. |
| CAT. III | Class III measurement is suitable for testing and measuring circuits connected to the distribution part of low voltage power supply devices in buildings. |
| CAT. IV | Class IV measurements are suitable for testing and measuring circuits connected to the power supply of low voltage power installations in buildings. |
2. Overview
The GVDA GD106B is a 4000-count digital multimeter with auto-ranging capabilities, True RMS measurement, and a variety of functions including AC/DC voltage, AC/DC current, resistance, capacitance, diode, continuity, NCV (Non-Contact Voltage) detection, live wire detection, and battery testing. Its new display and function layout provide a clearer and better user experience, making it an excellent choice for professional electricians, enthusiasts, and general household use.
2.1. Instrument Panel Description
- NCV probe
- Flashlight
- Red / green light
- LCD display
- Function keys
- Function knob
- COM Input socket
- Other measurement input socket
- 10A current Input socket
3. Setup
3.1. Battery Installation
The GVDA GD106B requires 2 x 1.5V AAA batteries (not included) for operation.
- Turn off the power supply of the instrument.
- Use a screwdriver to unscrew the screws fixing the battery cover and remove the cover.
- Remove old batteries (if any) and replace them with new batteries of the same specifications. Pay attention to the positive and negative polarity marks inside the battery cover.
- Install the battery cover back to its original position, fix, and lock it with screws.
⚠ WARNING: To prevent electric shock or personal injury caused by error readings, replace the battery promptly when the battery power is low. Do not short-circuit the battery or reverse battery polarity to discharge the batteries. To ensure safety and product maintenance, remove the batteries if the instrument will not be used for an extended period to avoid damage from battery leakage.
4. Operating Instructions
4.1. General Functions
- FUNC Key: When there are multiple measuring functions on a gear, press the FUNC key to switch between functions.
- Data Hold (HOLD): Press the "HOLD" key to enter or cancel data hold mode.
- Maximum Measurement (MAX): Press the "MAX" key to enter or cancel maximum measurement mode.
- Backlight: Press the backlight key (🔆) to turn on/off the backlight. The backlight will automatically shut down after about 10 seconds.
- Flashlight: Press and hold the flashlight key (🔆) for more than 2 seconds to turn on/off the flashlight.
- Auto Power Off: The instrument will turn off automatically after 15 minutes of no operation to save battery energy. Press any key to restore the working state. If you press the "FUNC." button and turn on the meter power, the automatic shutdown function will be canceled.
4.2. DC Voltage Measurement
- Turn the function knob to "V———".
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Contact the probes to the measured circuit (connect in parallel) to measure the voltage.
- Read the measurement result on the LCD display.
⚠ WARNING: Do not measure voltages above 600V, as this may damage the instrument. Pay special attention to safety when measuring high voltage to avoid electric shock or personal injury. Always test with a known voltage before use to confirm the instrument function is intact.
4.3. AC Voltage Measurement
- Turn the function knob to "V∼".
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Contact the probes to the measured circuit (connect in parallel) to measure the voltage.
- Read the measurement result on the LCD display.
⚠ WARNING: Do not measure voltages above 600V, as this may damage the instrument. Pay special attention to safety when measuring high voltage to avoid electric shock or personal injury.
4.4. DC/AC Current Measurement
- Turn the function knob to µA, mA, or A. Use the "FUNC." key to switch between AC or DC current functions.
- For µA/mA measurements, insert the red probe into the "+mAµA" socket. For 4A/10A measurements, insert the red probe into the "10A" socket. Always insert the black probe into the "COM" socket.
- Disconnect the power of the tested circuit. Connect the meter in series with the circuit under test, then turn on the circuit power supply.
- Read the measurement result.
⚠ WARNING: Do not measure current if the voltage is above 600V, as this may damage the instrument. When measuring large currents, continuous measurement should not exceed 15 seconds.
4.5. Resistance Measurement
- Turn the function knob to "Ω".
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Contact the probes to the measured circuit or resistance.
- Read the measurement result.
⚠ WARNING: When measuring resistance on a live circuit, disconnect the power supply and discharge all high-voltage capacitors. Otherwise, the instrument may be damaged and you may be struck by electric shocks.
4.6. Continuity Test
- Turn the function knob to "Ω)))" and switch to Continuity measurement function using the "FUNC." key.
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Contact the probes to the circuit or component to be tested.
- If the resistance is less than 30Ω, the buzzer will sound, and the green indicator light will illuminate. If the resistance is between 30Ω and 60Ω, the buzzer will not sound, and the indicator light will be red.
⚠ WARNING: When performing continuity tests on a live circuit, disconnect the power supply and discharge all high-voltage capacitors. Otherwise, the instrument may be damaged and you may be struck by electric shocks.
4.7. Diode Measurement
- Turn the function knob to "→+" and switch to diode measurement function using the "FUNC." key.
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Touch the diode anode with the red probe and the diode cathode with the black probe.
- Read the measurement result. The display shows the approximate forward voltage value of the diode.
⚠ WARNING: When measuring diodes on a live circuit, disconnect the power supply and discharge all high-voltage capacitors. Otherwise, the instrument may be damaged.
4.8. Capacitance Measurement
- Turn the function knob to "—||—".
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Contact the probes to the measured circuit or capacitor.
- Read the measurement result.
⚠ WARNING: When measuring capacitance on a live circuit, disconnect the power supply and discharge all high-voltage capacitors. Otherwise, the instrument may be damaged and you may be struck by electric shocks.
4.9. NCV (Non-Contact Voltage) Test
- Turn the function knob to "NCV Live".
- Gradually approach the NCV probe to the detected point.
- When the meter senses weak AC signals, the green indicator light will illuminate, and the beeps will be slow.
- When the meter senses strong AC signals, the red indicator light will illuminate, and the beeps will be fast.
⚠ WARNING: To avoid possible accidents such as electric shock or personal injury, please follow all safety regulations.
4.10. Live Test
- Turn the function knob to "NCV Live" shift, and switch to live test function using the "FUNC." key. The meter will display "LIVE".
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Touch the test point with the red probe.
- When the meter senses weak AC signals, the green indicator light will illuminate, and the beeps will be slow.
- When the meter senses strong AC signals, the red indicator light will illuminate, and the beeps will be fast.
⚠ WARNING: To avoid possible accidents such as electric shock or personal injury, please follow all safety regulations.
4.11. Battery Test
- Turn the function knob to the battery test position (1.5V or 9V) and select the appropriate range.
- Insert the red probe into the "+mAµA" socket and the black probe into the "COM" socket.
- Touch the positive terminal of the battery with the red probe and the negative terminal with the black probe.
- Read the measurement result.
Note: 1.5V range Load resistance: 30Ω | 9V range Load resistance: 300Ω
5. Maintenance
⚠ WARNING: Always keep the inside of the instrument clean and dry to avoid electric shock or instrument damage.
5.1. Cleaning
If there is dust on the terminal or if the terminal is wet, it may cause measurement errors. Please clean the instrument as follows:
- Switch off the power supply of the instrument and remove the test probe.
- Turn over the instrument and gently shake out any dust accumulated in the input socket.
- Wipe the outer cabinet with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents.
- Wipe contacts in each input socket with a clean cotton swab soaked in alcohol.
5.2. Replacing the Battery
Refer to Section 3.1 for detailed instructions on battery installation and replacement.
5.3. Replacing the Fuse
The GVDA GD106B uses the following fuses:
- mA: F400mA/250V fuse
- 10A: F10A/250V fuse
- Turn off the power supply of the instrument and remove the probe.
- Use a screwdriver to unscrew the screws fixing the back cover and remove the back cover.
- Remove the burnt fuse and replace it with a new fuse of the same specifications. Ensure the fuse is clamped securely in the safety clip.
- Install the back cover, fix, and lock it with screws.
⚠ WARNING: To avoid possible electric shock, personal injury, or instrument damage, use only fuses with the same specifications as specified.
6. Troubleshooting
- "OL" Display: Indicates an over-range condition. The measured value exceeds the selected range. Switch to a higher range or check the circuit.
- Low Battery Indicator: The battery symbol (🔋) will be displayed when the battery voltage is lower than normal working voltage. Replace batteries promptly to ensure accurate measurements.
- No Display/Instrument Not Turning On: Check battery installation and ensure batteries are not depleted.
- Inaccurate Readings: Ensure probes are correctly connected and not damaged. Check for proper function selection. Replace batteries if low.
7. Specifications
7.1. General Technical Specifications
- Display: 4000 Counts Digital Display
- Sampling Rate: Approximately 3 times/second
- Input Polarity Indication: Automatically displays "-"
- Over Range Indication: Displays "OL"
- Low Battery Indication: Battery symbol displayed
- Auto Power Off: After 15 minutes of inactivity
- Operating Mode: Auto Range
- True RMS: Yes
- NCV Measurement: Yes
- Live Wire Test: Yes
- Data Hold: Yes
- Maximum Measurement: Yes
- Backlight: Yes
- Flashlight: Yes
- Power Supply: 2 x 1.5V AAA batteries (not included)
- Dimensions: 151mm x 75mm x 46mm
- Product Weight: 207g
- Operating Temperature: 0 - 40 ℃
- Operating Humidity: <80% RH (non-condensing below 10℃)
- Storage Temperature: -10 - 60 ℃
- Storage Humidity: <70% RH (remove battery)
- MAX. Voltage between terminals and earth ground: 600V
- Certification: CE, FCC
- DIY Supplies: Electrical
- Origin: Mainland China
7.2. Accuracy Specifications (Applies within one year after calibration, at 18℃ to 28℃ and <80% RH)
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 400mV | 0.1mV | ±(0.5%+3) |
| 4V | 0.001V | ||
| 40V | 0.01V | ||
| 400V | 0.1V | ||
| 600V | 1V | ||
| Input impedance: 10MΩ; Overload protection: 600V | |||
| AC Voltage | 4V | 0.001V | ±(1.0%+3) |
| 40V | 0.01V | ||
| 400V | 0.1V | ||
| 600V | 1V | ||
| Input impedance: 10MΩ; Overload protection: 600V; Maximum input voltage: 600V; Frequency Response: 10Hz ~ 1kHz, TRMS | |||
| DC Current | 400µA | 0.1µA | ±(1.2%+3) |
| 4000µA | 1µA | ||
| 40mA | 0.01mA | ||
| 400mA | 0.1mA | ||
| 4A | 0.001A | ||
| 10A | 0.01A | ||
| Overload protection: µA/mA: F400mA/250V fuse; A: F10A/250V fuse; Maximum input current: µA/mA: 400mA; A: 10A. When measuring large current, continuous measurement should be no longer than 15 seconds. | |||
| AC Current | 400µA | 0.1µA | ±(1.5%+3) |
| 4000µA | 1µA | ||
| 40mA | 0.01mA | ||
| 400mA | 0.1mA | ||
| 4A | 0.001A | ||
| 10A | 0.01A | ||
| Overload protection: µA/mA: F400mA/250V fuse; A: F10A/250V fuse; Maximum input current: mA: 400mA; A: 10A; Frequency Response: 10Hz ~ 1kHz, TRMS. When measuring large current, continuous measurement should be no longer than 15 seconds. | |||
| Resistance | 400Ω | 0.1Ω | ±(1.0%+3) |
| 4kΩ | 0.001kΩ | ||
| 40kΩ | 0.01kΩ | ||
| 400kΩ | 0.1kΩ | ||
| 4MΩ | 0.001MΩ | ±(1.2%+3) | |
| 40MΩ | 0.01MΩ | ||
| Overload protection: 250V | |||
| Capacitance | 4nF | 0.001nF | ±(4.0%+5) |
| 40nF | 0.01nF | ||
| 400nF | 0.1nF | ||
| 4µF | 0.001µF | ||
| 40µF | 0.01µF | ||
| 400µF | 0.1µF | ||
| 4mF | 0.001mF | ||
| Overload protection: 250V | |||
| Diode | Forward DC current: ~1mA; Reverse DC voltage: ~2.5V; Overload protection: 250V. Displays approximate forward voltage value. | ||
| Continuity | Open circuit voltage: ~0.5V; Overload protection: 250V. Buzzer sounds and green light for <30Ω; no buzz and red light for >30Ω and <60Ω. | ||
8. User Tips
- The multimeter is compact and offers many functions, making it suitable for various tasks.
- The LED indicator and beeper for live wire detection are helpful features, especially in dimly lit conditions.
- The rubber-coated body provides durability and a good grip.
- Consider purchasing additional probes if specialized testing is required, although the included probes are generally sufficient for basic use.
- This device is accurate enough for general home or car use.
9. Warranty and Support
For any questions or support regarding your GVDA GD106B Digital Multimeter, please refer to the official product page or contact the seller directly. This manual is intended for informational purposes and does not constitute a warranty statement.
A user manual in PDF format is available for download: View User Manual (PDF)