1. Product Introduction
The Gaqqee 6839C Intelligent Electricity Meter is a versatile digital voltage and power indicator designed for monitoring various battery types, including ternary lithium, lithium iron, and lead-acid batteries. It features a high-definition color display, real-time voltage and temperature monitoring, and configurable alarm reminders to ensure battery safety. This meter is suitable for a wide range of applications such as electric vehicles, RVs, unmanned base stations, and energy storage equipment.



2. Safety Precautions
- Ensure the power supply is disconnected before installation or wiring to prevent electric shock.
- Verify that the voltage range of your battery system is compatible with the meter (DC 8-100V).
- Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
- Keep the device away from water, moisture, and extreme temperatures.
- Non-professionals should avoid using the voltage calibration function as it may affect accuracy.
3. Package Contents
Upon opening the package, please ensure all items are present and in good condition:
- 1 x Gaqqee 6839C Intelligent Electricity Meter
- 1 x Connecting Cable
- Optional: Mounting Bracket (if selected during purchase)

4. Specifications
| Feature | Specification |
|---|---|
| Model Number | 6839C |
| Voltage Measurement Range | DC 8 - 100V |
| Resolution | 0.01V |
| Operating Current | ≤ 20mA |
| Static Power Consumption | < 2mA |
| Screen Type | Color (wide viewing angle) |
| Detection Accuracy | ± 1% |
| Scan Speed | 1 scan/500ms |
| Operating Temperature | -20 to 80℃ |
| Dimensions | 68.78mm * 38.8mm * 14.3mm |
| Alarm Reminder | Built-in flashing light, audible alarm |
| Battery Included | No |
| Data Record | No |


5. Setup and Installation
The meter comes with a simple two-wire connection. Connect the red wire to the positive (+) terminal of your battery system and the black wire to the negative (-) terminal. Ensure a secure connection to avoid inaccurate readings or damage.

For mounting, if you have the optional bracket, attach it to a suitable surface using the provided hardware. The meter can then be secured to the bracket.

6. Operating Instructions
The product defaults to monitoring 3 strings of ternary lithium battery voltages. The display shows real-time voltage (VOL), temperature (TEMP), and battery percentage.

Basic Operation
- Power On/Off Display: On the home page, short-press the power button to turn the display on and off.
- Enter Setup Mode: Press and hold the SET button for 2 seconds to enter the setup mode.
Mode Setting Instructions
Once in setup mode, short-press the button to navigate through the different menus (Menu 1 to Menu 9). To confirm a selection or save a setting, press and hold the button for 2 seconds.
1. Ternary Lithium Battery Settings (Menu 1)
On the main page, press and hold the button for 2 seconds to enter the settings page. 'L-003' (ternary lithium battery 3 strings) will be displayed. On the L-003 page, press and hold the button for 2 seconds, and the value '03' will flash. Short press the button to select the number of battery strings from 03 to 22. After selecting, press and hold the button for 2 seconds to confirm (the value will become solid). Press and hold the button for 2 seconds again to return to the main page, or short press to go to the next settings page.

2. Iron-Lithium Battery Settings (Menu 2)
From the main page, press and hold the button for 2 seconds to enter settings. Short press the button to switch to the 'F-003' page (3 strings of iron-lithium batteries). On the F-003 page, press and hold the button for 2 seconds, and '03' will flash. Short press to select the number of battery strings from 03 to 26. Confirm by pressing and holding for 2 seconds. Return to main page by pressing and holding for 2 seconds again, or short press for the next settings page.

3. Lead-Acid Battery Settings (Menu 3)
From the main page, press and hold the button for 2 seconds to enter settings. Short press the button to switch to the 'P-12' page (lead-acid battery 12V). On the P-12 page, press and hold the button for 2 seconds, and '12' will flash. Short press to select the voltage (12V/24V/36V/48V/60V/72V/84V). Confirm by pressing and holding for 2 seconds. Return to main page by pressing and holding for 2 seconds again, or short press for the next settings page.

4. Custom Voltage Settings (Menu 4)
From the main page, press and hold the button for 2 seconds to enter settings. Short press to switch to the custom voltage setting page (displaying high and low voltage values). Press and hold the button for 2 seconds; the first value will flash. Short press to select the desired value (loops). Press and hold for 2 seconds again; the first value will remain on, and the second value will flash. After setting both values, short press to enter the second row of settings. After setting, press and hold for 2 seconds to return to the main page, or short press for the next settings page.
5. Backlight Settings (Menu 5)
From the main page, press and hold the button for 2 seconds to enter backlight settings. Short press to switch to the 'BL' page. On the BL page, press and hold the button for 2 seconds, and '00' will flash. Short press to select backlight duration (00 always on, 10-90 seconds). Confirm by pressing and holding for 2 seconds. Return to main page by pressing and holding for 2 seconds again, or short press for the next settings page.
6. High and Low Voltage Alarm Settings (Menu 6)
From the main page, press and hold the button for 2 seconds to enter settings. Short press to switch to the high and low pressure alarm settings page (displaying high and low pressure values). Follow the same procedure as custom voltage settings to set the high and low alarm thresholds. Confirm by pressing and holding for 2 seconds. Return to main page by pressing and holding for 2 seconds again, or short press for the next settings page.


7. Voltage Calibration Setting (Menu 7)
Important: This product is factory calibrated. Non-professionals should NOT use this function as unauthorized operation will affect voltage accuracy. Contact the manufacturer if required.
From the main page, press and hold the button for 2 seconds to enter settings. Short press to switch to the electronic calibration function page ('CL'). On the CL page, press and hold the button for 2 seconds, and the displayed voltage will flash. Press and hold the button for 2 seconds again to complete automatic calibration and return to the main page.
8. SOC Mode Setting (Menu 8)
Important: Users cannot set this function. Please contact the manufacturer.
From the main page, press and hold the button for 2 seconds to enter settings. Short press to switch to the SOC settings page ('SO'). On the SO page, press and hold the button for 2 seconds, select 'ON' or 'OF' on the right. Press and hold the button for 2 seconds to confirm. Press and hold the button for 2 seconds again to return to the main page, or short press for the next settings page.
9. Restore Factory Settings (Menu 9)
Important: Non-professionals should NOT use this function, otherwise it will affect the use of the product.
From the main page, press and hold the button for 2 seconds to enter settings. Short press to select the factory reset page ('RF'). On the RF page, press and hold the button for 2 seconds. The three '8's on the left will flash, then turn into three '0's. Press and hold the button for 2 seconds to restore factory settings. The three '0's will then light up steadily, indicating the factory reset is complete. Press and hold the button for 2 seconds to return to the main page, or short press to enter the next settings page (Menu 1).
7. Maintenance
- Keep the meter clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Ensure all connections are secure and free from corrosion.
- Store the device in a dry environment within the specified operating temperature range.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Power off | Incorrect wiring, no power, or display turned off. | Check wiring connections. Ensure battery has power. Short-press the power button to turn on the display. |
| Inaccurate readings | Incorrect battery type setting, loose connection, or calibration issue. | Verify battery type settings (Menu 1-3). Check wiring. If persistent, contact manufacturer for calibration advice. |
| Alarm constantly active | Voltage outside set thresholds. | Check battery voltage. Adjust high/low alarm settings (Menu 6) if thresholds are inappropriate for your battery. |
| Settings not saving | Settings not confirmed correctly. | Ensure you press and hold the button for 2 seconds to confirm each setting change. |

9. User Tips
- Always double-check your battery type and string count before setting up the meter to ensure accurate readings.
- For optimal visibility, consider the wide viewing angle of the display when choosing a mounting location.
- Regularly monitor the voltage and temperature readings to understand your battery's health and prevent unexpected issues.
10. Warranty and Support
For warranty information, technical support, or inquiries regarding optional features like buzzer/temperature functions or SOC mode, please contact the manufacturer or your point of purchase. Keep your purchase receipt for any warranty claims.
A user manual in PDF format is available for download: View User Manual (PDF)
11. Frequently Asked Questions
- Q: Can I use this meter with any battery type?
- A: The meter is compatible with ternary lithium, lithium iron, and lead-acid batteries. You must configure the correct battery type and string count in the settings for accurate readings.
- Q: Is the meter waterproof?
- A: The specifications do not explicitly state a waterproof rating. It is recommended to protect the device from water and moisture.
- Q: How do I know if my battery is overcharged or over-discharged?
- A: The meter supports configurable high and low voltage alarm reminders. You can set thresholds, and the meter will provide a timely warning if the voltage falls outside these limits.