Gaqqee LCR digital tweezers bridge

Contents

Gaqqee LCR Digital Tweezers Bridge Meter User Manual

Model: LCR Digital Tweezers Bridge

1. Safety Precautions

To avoid possible electric shock, fire, and personal injury, please read the following safety instructions carefully before use:

  • Do not measure voltage to prevent damage to the instrument and causing personal injury.
  • Do not use the instrument in flammable, explosive, or high-temperature environments. Voltage input is strictly prohibited.
  • Do not use this product in the vicinity of explosive gases and vapors or in a damp environment.
  • Used batteries from replaced instruments and scrapped instruments must not be disposed of together with household garbage. Please handle them in accordance with relevant national or local laws and regulations.
Precautions list for LCR Digital Tweezers Bridge Meter

Image: A list of precautions for using the LCR Digital Tweezers Bridge Meter.

2. Product Introduction

The Gaqqee LCR Digital Tweezers Bridge Meter is a newly developed handheld LCR bridge designed for precise measurement of electronic components. It features a built-in 250mAh rechargeable lithium polymer battery, offering long standby time and fast measurement speed. The 1.14-inch TFT color display provides a clear and intuitive interface.

This multi-functional and portable instrument supports accurate measurement of resistors, capacitors, inductors, and diodes. It utilizes advanced measurement technology for high precision and stability, supporting three test frequencies: 100Hz, 1KHz, and 10KHz. Its unique tweezer-shaped design is ideal for fine operations and quick testing of components in confined spaces, making it an essential tool for field engineers and laboratories.

LCR Tester in hand showing smart recognition features

Image: The LCR Tester held in hand, highlighting its smart recognition capabilities for resistors, capacitors, and inductors, along with displayed parameters like RS, D-value, Q-value, Z-value, and X-value.

LCR Tester demonstrating multiple measurement types

Image: The LCR Tester performing various measurements including resistance, capacitance, inductance, and diode tests.

Play video
Watch video online

Video: A demonstration of the LCR Digital Tweezers Bridge Meter in use.

3. Panel Introduction and Controls

LCR Tester and accessories

Image: The LCR Tester, USB Type-C cable, and user manual included in the product package.

LCR Tester display with parameter definitions

Image: Close-up of the LCR Tester display showing parameter definitions: D (Loss factor), Q (Quality factor), Z (Impedance), OL (Series resistance), pF (Unit symbol), X (Reactance).

3.1. Buttons and Indicators

  1. Power Button (1): Short press to power on, long press to power off.
  2. Hold/Setting Button (2): Short press to hold data, long press to enter/exit the setting menu.
  3. Charging Indicator Light (3): Red light indicates charging (not fully charged), green light indicates fully charged.
  4. Left Setting Button (4): Used for left/top adjustment in the main interface/settings interface.
  5. Interface Setting Button (5): Used to confirm adjustments of left/right/up/down options in the main interface/settings interface. Long press to switch the displayed secondary parameters.
  6. Right Setting Button (6): Used for right/down adjustment in the main interface/settings interface. Long press to rotate the screen.

3.2. Display Elements

  1. Measuring mode indicator.
  2. Measuring electrical level indicator.
  3. Test frequency indicator.
  4. Battery level display.
  5. Measurement mode function symbol indication.
  6. Measurement unit symbols.
  7. Rs measurement value display.
  8. D (loss value), Q (quality factor), Z (impedance), X (reactance) display. Long press button 5 to switch between displayed secondary parameters.
LCR Tester control buttons

Image: Diagram showing the control buttons (Power, M, S, and arrow keys) and their functions on the LCR Tester.

4. Operating Instructions

4.1. Basic Operation

  • Power On/Off: Short press button 1 to power on, long press to power off.
  • Test Main Parameter Selection: Use buttons 4 and 6 to switch between measurement modes: Auto, Resistance, Capacitance, Inductance, and Diode.
  • Test Level Selection: Press button 5 to enter level selection mode. Then use buttons 4 and 6 to switch between 0.3V and 0.6V test levels.
  • Test Frequency Selection: Press button 5 again to enter the frequency selection mode. Then use buttons 4 and 6 to switch between the 100Hz, 1KHz, and 10KHz test frequencies.
  • Data Retention: Short press button 2 to hold data.

4.2. Measurement Procedures

4.2.1. Measuring Resistance

  1. Use the AUTO mode or manually adjust to the resistance mode.
  2. Ensure that the two test ends of the tweezers are reliably in contact with the resistance to be measured.

Note:

  • If the resistance under test is oxidized or has poor contact, it will affect the measurement accuracy.

4.2.2. Measuring Capacitance

  1. Use the AUTO mode or manually adjust to the capacitor mode.
  2. Ensure that the two test ends of the tweezers are reliably in contact with the capacitor to be measured.

Note:

  • Before measuring capacitance, it is necessary to discharge the capacitance to avoid damaging the instrument. When measuring capacitance, attention should be paid to choosing the measurement frequency.

4.2.3. Measuring Inductance

  1. Use the AUTO mode or manually adjust to the inductance mode.
  2. Ensure that the two test ends of the tweezers have reliable contact with the inductance to be measured.

4.2.4. Diode Measurement / Buzzer Measurement

  1. Trigger button 4 or button 6 to manually switch to the diode position. The diode under test will make reliable contact with the two tweezers pins, and the polarity of the diode will be automatically displayed on the screen. The test range is between 0.1 and 0.9. If it exceeds the range, "OL" will be displayed.
  2. When testing the buzzer in diode mode, if the measured value is 50±10Ω, the buzzer will produce a continuous beeping sound, indicating continuity.

5. Calibration Instructions

When calibration is required, follow these steps:

  1. The calibration options include 0Ω, 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ, 1MΩ, 10MΩ, and an open circuit (OPEN) option. Calibration can be performed for each range individually.
  2. To enter calibration settings, press and hold button 4 and button 1 simultaneously to turn on the device.
  3. Once in calibration settings, press button 6 to select the desired calibration gear.
  4. Ensure the two test ends of the tweezers make effective contact with the standard resistor for the selected calibration.
  5. Press button 2 to start the calibration process and wait patiently for about 20 seconds.
  6. Upon completion, the buzzer will beep once, and the screen will display "calibration successful". If calibration fails, the buzzer will beep twice, and the screen will display "calibration failure".
  7. To proceed to the next calibration level (if needed), press button 6.

Important Notes for Calibration:

  • Use a carbon film resistor for standard resistor calibration, not a wire-wound resistor.
  • For 0Ω calibration, calibrate by placing the tips of the tweezers directly against each other (short circuit).
  • OPEN calibration does not require contact with any resistors. Keep the tips of the tweezers open for this calibration.

6. Specifications

Parameter Value
Product ModelLCR
Display Type1.14 inch TFT Color Screen
Operating ModeAuto Range
Measuring Capacitance Range1pF-22mF
Measuring Inductance Range1μH-10H
Measuring Resistance Range10mΩ-10MΩ
Diode Conduction Voltage0.7V
Test Frequencies100Hz, 1KHz, 10KHz
Parameter DisplayRS, D-value, Q-value, Z-value, X-value
Charging InterfaceType-C, 5V/A
Power Supply250mAh Lithium Battery
Automatic Recognition MeasurementSupported
Replaceable Probe TipsSupported
Automatic ShutdownSupported (Configurable: Off/5/15/30 minutes)
Data RetentionSupported
Operating Temperature0 - 40 ℃
Dimensions28x19x150mm (approx. 1.13in x 2.45in x 5.98in)
Weight41g
Product Specifications table

Image: Detailed product specifications including ranges for capacitance, inductance, and resistance at different test frequencies.

LCR Tester features icons

Image: Icons representing key features: Main and Auxiliary Parameter Display, Level/Frequency Adjustment, AUTO Automatic Recognition, Type-C Direct Lithium Battery Charging, 1.14-inch HD Color Screen, Chinese-English Language Switching.

7. Maintenance and Troubleshooting

7.1. General Precautions

  • Before measurement, ensure that the tweezers are in good contact with the object to be measured to avoid measurement errors caused by poor contact.
  • Do not measure voltage to prevent damage to the instrument.
  • It is not recommended to measure online. Due to the connection attribute of the external PCBA, online measurement is for reference only.
  • The auto-measuring mode cannot measure diodes. When the diode is short-circuited, it is normal for a resistance value to be displayed.
  • Before measuring the capacitance, it is necessary to discharge the capacitance to prevent damage to the instrument.

7.2. Settings Menu

To access system settings, long press button 2. Use buttons 4 and 6 to navigate between menu items, and button 5 to enter/exit sub-menus. Available settings include:

  • System Language: Switch between Chinese and English.
  • Volume Setting: Adjustable from 0 to 5 levels.
  • Screen Brightness: Adjustable from 0-100 with a stepless dimmer.
  • Automatic Shutdown: Set to Off, 5, 15, or 30 minutes of inactivity.
  • Restore Factory Settings: Clears all user-defined settings.
  • About: View model and version number.
Comparison of LCR Tweezers and Multimeter

Image: A comparison highlighting the capabilities of the Digital Bridge Tweezer (automatic component measurement, switchable Chinese/English, measures inductance, D(loss value), Q(quality factor), Z(impedance), X(reactance)) versus a standard Digital Multimeter (AC/DC Voltage and Current, non-switchable language, measures resistance).

8. User Tips

  • For accurate capacitance readings, always ensure the capacitor is fully discharged before testing.
  • Utilize the automatic recognition feature for quick identification of component types.
  • When working with small surface-mount components, the tweezer design provides excellent precision and ease of use.
  • Remember to check the battery level regularly, especially before critical measurements, to ensure uninterrupted operation.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the seller directly. A PDF version of this user manual is available for download at this link.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.