1. Product Overview

The DZ47S-63 Motor Phase Loss Protection Switch is a robust circuit breaker designed for three-phase electrical systems. It provides essential protection against phase loss, overload, and short circuits, ensuring the safe and reliable operation of industrial motors and reducing potential equipment damage and downtime.

DZ47S-63 Three-Phase Breaker with key features
Image: DZ47S-63 Three-Phase Breaker highlighting short circuit/overload protection, phase loss/failure protection, rated frequency 50Hz, rated motor power 12kW, rated voltage AC 380V, and DIN rail mounting.
DZ47S-63 Circuit Breaker protecting motors from phase loss and damage
Image: DZ47S-63 Circuit Breaker with labels for Phase Loss Protection, Overload Protection, Short Circuit Protection, and Instant Cut-Off.

This device is ideal for various applications including motor control centers, industrial equipment, HVAC systems, distribution panels, and factory distribution.

Applications of the DZ47S-63 circuit breaker
Image: Visual representation of the DZ47S-63 circuit breaker being ideal for various applications such as Motor Control Centers, Industrial Equipment, HVAC Systems, Distribution Panels, and Factory Distribution.

Key Features:

  • Multi-layer protection system: Provides comprehensive protection against phase loss, overload, and short circuits to ensure motor safety.
  • Fast tripping response: Trips within ≤0.3 seconds to effectively prevent motor burnout and minimize downtime.
  • Electromagnetic trip mechanism: Delivers accurate and reliable protection in case of short circuits.
  • Arc extinguishing chamber: Rapidly suppresses electrical arcs, enhancing operational safety and durability.
  • Fire-resistant insulation: Flame-retardant housing ensures safe use even in demanding environments.
  • Secure and flexible installation: Designed for quick DIN rail mounting, with optional screw fixing for added stability.
  • Linked handle mechanism: Ensures synchronized operation and improved control performance.

2. Specifications

Product Parameters
Parameter Value
Product Name Motor Phase Loss Protection Switch
Model DZ47S-63 Series
Rated Voltage AC 380V
Frequency 50Hz
Poles 3P
Phase Loss Trip Time ≤ 0.3s
Protection Functions Phase loss, overload, short circuit
Installation Method DIN rail mounting
Rated Motor Power 12 kW
EU LVD Voltage High voltage: Above 50Vac or 75Vdc
Wireless Functionality No
Includes Battery No
High-concerned chemical None
Detailed product dimensions and specifications for DZ47S-63
Image: Detailed product dimensions (102mm x 96mm x 76mm) and a table of specifications including product name, rated voltage, model, phase loss tripping time, number of poles, function, and installation method. Also shows 3P (16A/32A/63A) occupies 5.5 ways in distribution box, weight 0.330KG.

3. Setup and Installation

Preparation:

  • Ensure the power supply is completely disconnected before beginning installation.
  • Mount the device securely on a standard DIN rail. The secure DIN rail clip design allows for easy mounting and can be supplemented with screws for additional fixation if desired.
  • Before switching on the power for the first time, press the blue reset button.
Detailed view of the DZ47S-63 Phase Loss Protection Switch components and wiring diagram
Image: Detailed view of the DZ47S-63 switch showing the Wiring Diagram, Indicator Window, Test Button, Leakage Indicator, Line Input Terminal, Operating Handle, and Line Output Terminal. It also highlights Mechanical Interlocking Handle Linkage Mechanism, Electromagnetic Trip (Short Circuit Protection), Arc Extinguishing Chamber (Rapid Arc Extinguishing), and Fire-Resistant and Flame-Retardant material.
Wiring diagram for the DZ47S-63 circuit breaker
Image: Wiring diagram showing Power Input connected to the top terminals of the breaker and Output Terminal connected to a motor from the bottom terminals.

4. Operating Instructions

Operation:

After proper installation, energize the system. The switch will continuously monitor the circuit for anomalies. In the event of phase loss, overload, or short circuit, the device will trip automatically to protect the connected motor.

Data Reading and Indicators:

  • If the reset button pops up, it indicates that the switch has tripped. Identify and resolve the fault before resetting.
  • The visual indicator window shows the power on/off status. A green indicator window means the circuit is disconnected, while a red indicator window means the circuit is connected.
DZ47S-63 Circuit Breaker showing instant cut-off during a fault
Image: DZ47S-63 Circuit Breaker illustrating an instant cut-off with a yellow indicator light and electrical discharge graphics, emphasizing protection.
Visual indicator window on the DZ47S-63 circuit breaker
Image: Close-up of the DZ47S-63 showing the visual indicator window. It depicts a green indicator for disconnected and a red indicator for connected states.

5. Maintenance

  • Regular Testing: Use the yellow "T" test button monthly to verify proper operation of the protection mechanism.
  • Cleaning: Clean the exterior with a dry cloth. Do not use solvents or water directly on the device.
  • Inspection: Periodically inspect the device for signs of wear, damage, or loose connections.
  • Storage: Store the product in a dry, well-ventilated environment away from direct sunlight and corrosive substances.

6. Troubleshooting

Issue: The reset button pops up and the device trips.

Solution: This indicates that the switch has detected a fault (phase loss, overload, or short circuit). Identify and resolve the underlying electrical fault in your system before attempting to reset the breaker. Once the fault is cleared, press the blue reset button to restore power.

7. User Tips

  • The internal protection structure is robust, providing reliable overload protection during daily operation.
  • Ensure proper wiring into the control cabinet for optimal performance.

8. Frequently Asked Questions (FAQ)

Q1: Is this suitable for all three-phase motors?
A: It is compatible with most three-phase motors within the specified voltage and current range.
Q2: How is the product installed?
A: It supports standard DIN rail mounting and can also be secured with screws if needed.
Q3: What happens if phase loss occurs?
A: The breaker will trip within ≤0.3 seconds, immediately stopping the motor to prevent damage.

9. Safety Warnings

WARNING!

  • Risk of Electric Shock: Ensure complete disconnection from the power supply before installation or servicing.
  • High Voltage Equipment: Improper handling of high voltage equipment can result in serious injury or equipment damage.
  • Do not touch live parts during operation.
  • Keep out of reach of children.
  • Proper Disposal: Follow WEEE directives for electronic waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination country.

10. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.

11. Warranty and Support

For technical consultations or any inquiries, please contact us:

  • WhatsApp: +86 13311678550
  • Email: miazhao008@gmail.com
Contact information for technical support including WhatsApp and Email
Image: Contact information for technical support, showing WhatsApp number and Email address.

You can also refer to the official user manual PDF for more detailed information: User Manual (PDF)

For a visual overview of the product and manufacturing process, please watch the video below:

Video: An overview of the SONGGER brand, showcasing manufacturing processes and various industrial applications of their automation solutions.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.