KKMOON GS04219

Contents

Hydraulic Pressure Gauge User Manual

Model: GS04219

1. Introduction

This manual provides essential information for the safe and effective use of your KKMOON Hydraulic Pressure Gauge. Please read this manual thoroughly before installation and operation, and retain it for future reference.

2. Product Overview

The KKMOON Hydraulic Pressure Gauge is designed for accurate measurement of hydraulic and water pressure. It features a robust metal outer case for durability and protection of internal components, a clear 63mm dial with dual scales for both Bar and PSI readings, and a standard G1/4 thread connection for easy installation.

Front view of the hydraulic pressure gauge
Figure 1: Front view of the hydraulic pressure gauge, showing dual scale (bar/psi) and metal outer case.
Multiple views of the pressure gauge
Figure 2: Multiple views of the pressure gauge, including front, back, and connection details.

3. Safety Information

WARNING: To avoid danger of suffocation, keep any plastic packaging away from babies and children.

Always ensure the gauge is installed by a qualified professional in accordance with local regulations and safety standards. Do not exceed the maximum rated pressure of the gauge.

4. Specifications

Feature Detail
Product Name Hydraulic Water Pressure Gauge Meter
Model GS04219
Batch/Serial Number ALI9302462694
Material Metal (outer case)
Display Type Analog
Dial Plate Diameter 63mm (2.48 inches)
Measurement Range 0-250 Bar / 0-3750 PSI
Connection Thread G1/4
Weight 210g
Package Dimensions (L x W x H) 17cm x 16cm x 4cm
Package Weight 0.217 kg
Origin Mainland China
Certification None
Diagram showing the 63mm dial diameter
Figure 3: Diagram illustrating the 63mm (2.48 inch) dial diameter.

5. Setup

  1. Unpacking: Carefully remove the pressure gauge from its packaging. Inspect for any signs of damage.
  2. Connection: The gauge features a G1/4 thread connection. Ensure the system you are connecting it to has a compatible G1/4 female thread port.
  3. Installation: Screw the gauge firmly into the designated port. Use appropriate sealing tape (e.g., PTFE tape) on the threads to ensure a leak-free connection. Do not overtighten, as this can damage the threads or the gauge.
  4. Positioning: Ensure the gauge is positioned so that the dial is clearly visible for easy reading.
Close-up of the G1/4 thread connection
Figure 4: Close-up view of the G1/4 thread connection.

6. Operating Instructions

Once installed, the pressure gauge operates automatically. The needle on the dial will indicate the current pressure in the system.

  • Reading the Dial: The gauge has a dual scale. The outer scale (red markings) typically indicates PSI, and the inner scale (black markings) indicates Bar. Read the value corresponding to the tip of the needle.
  • Clear Markings: The dial features clear number markings for convenient and easy reading of pressure values.

7. Maintenance

  • Regular Inspection: Periodically check the gauge for any visible damage, cracks in the casing, or fogging of the dial.
  • Cleaning: Clean the exterior of the gauge with a soft, damp cloth. Do not use harsh chemicals or abrasive materials that could damage the dial or casing.
  • Connection Integrity: Ensure the connection remains tight and free of leaks.
  • Storage: If removing the gauge for storage, ensure it is clean and stored in a dry, protected environment to prevent damage.

8. Troubleshooting

  • No Reading: Ensure the gauge is correctly installed and the system is pressurized. Check for blockages in the connection port.
  • Inaccurate Reading: If you suspect an inaccurate reading, compare it with a known calibrated gauge. The gauge may need replacement if it consistently reads incorrectly.
  • Leakage at Connection: Re-check the thread sealant (e.g., PTFE tape) and ensure the gauge is tightened appropriately.
  • Damaged Dial/Casing: If the dial is cracked, fogged, or the casing is severely damaged, the gauge should be replaced immediately to ensure safety and accuracy.

9. User Tips

  • For optimal readability, install the gauge at eye level in a well-lit area.
  • Always ensure the system pressure does not exceed the maximum range of the gauge to prevent damage.
  • Consider using a snubber or pulsation dampener in systems with high pressure fluctuations to extend the life of the gauge.

10. Warranty & Support

For detailed product information, including a comprehensive user manual in PDF format, please refer to the official documentation provided by the seller. A PDF user manual is available at: Hydraulic Pressure Gauge User Manual (PDF).

Manufacturer Information:

  • Company Name: shang hai jiu tao mao yi Co., Ltd
  • Full Address: No.1, Lane 9, Songjian Road, Chonggu Town, Qingpu District, Shanghai, China (C-40)
  • Email: a157sumuitn2813@163.com
  • Telephone: 86-13876659213

EU Authorized Representative:

  • AR Company Name: SOLID AUTHORITY LIMITED
  • Full Address: 51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Ireland
  • Email: phoebe8706@gmail.com
  • Telephone: 353-76144379

© 2024 KKMOON. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.