1. Introduction
Thank you for purchasing the constant voltage constant current DC power supply produced by Hangzhou Ruideng Technology Co., Ltd. This manual provides detailed instructions to help you understand the full functionality of this product, ensure a better user experience, and prevent misuse. Please read this instruction carefully before use and keep it for future reference.
Note: This instruction corresponds to RD6024(V1.40) and RD6024W. Page layouts and operations may differ slightly with different firmware versions. We recommend downloading the latest firmware for the best experience.
2. Safety Information
- Input Voltage: The power source input interface must be connected to a 7-70V constant DC power source. If the input voltage exceeds 72V, the output will automatically turn off, and an alarm will be prompted. Exceeding this limit can directly damage the product.
- External Temperature Sensor: The external temperature sensor cable must be connected to the external temperature sensor interface.
- Fan Interface: The fan interface cannot be connected to other fans.
- Over Temperature Protection: If the system temperature exceeds 80°C, the output will shut down and display 'OTP' on the screen.
- Fuse Replacement: If a fuse is damaged, please solder a new fuse. When using a fuse holder as a temporary replacement, ensure the output current is less than 10A, as fuse holders typically have a maximum capacity of 10A.
- Battery Charging: Non-professionals should not use the battery charging function due to the risk of fire and explosion. Always use the original charger for batteries. Ensure you know your battery parameters well.
- Assembly: Only connect cables if you have a foundation in electronic and electrical engineering. The device must be reliably grounded.
- PSU Check: If you order a Power Supply Unit (PSU), use a multimeter to check if the real output voltage is stable and fits the rated voltage before connecting it to the RD power supply. Abnormal output can cause damage.
3. Package Contents
The product is packaged in a square carton. Upon opening, you will find the following items:
- RD Power Supply Unit (RD6024 or RD6024-W) x1
- Backup Fuse x1
- External Temperature Sensor (10K B3950) x1
- WiFi/RS485 Communication Board (optional, order separately)
- Chinese and English Instruction Card

4. Specifications
| Parameter | Value |
|---|---|
| Model | RD6024/RD6024-W |
| Input Voltage Range | 6-70.00V |
| Output Voltage Range | 0-60.00V |
| Output Current Range | 0-24.00A |
| Output Power Range | 0-1440W |
| Input Voltage Measurement Resolution | 0.01V |
| Output Voltage Setting Measurement Resolution | 0.01V |
| Output Current Setting Measurement Resolution | 0.01A |
| Battery Voltage Measurement Resolution | 0.01V |
| Input Voltage Measurement Accuracy | ±(1%+5 digits) |
| Output Voltage Accuracy (setting to measurement) | ±(0.3%+3 digits) |
| Output Current Accuracy (setting to measurement) | ±(0.5%+5 digits) |
| Battery Voltage Measurement Accuracy | ±(0.5%+3 digits) |
| Automatic Cut-off Current (charging) | Set by user (higher than 100mA) |
| Output Ripple Typical | 100mV@12A, 150mV@24A VPP |
| Working Temperature Range | -10℃~40℃ |
| External Sensor Temperature Detection Range | -10℃~100℃/0℉~200℉ |
| External Sensor Temperature Detection Accuracy | ±3℃/±6℉ |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A Load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99Wh |
| Capacity and Energy Statistical Error | ±2% |
| Buck Working Mode | (Input voltage ÷ 1.1) - 1 |
| Over Temperature Protection | System temperature > 80℃ |
| Screen Brightness Setting | 0-5 (6 levels in total) |
| Screen | 2.4 inch color HD display |
| Weight (with package) | About 0.72kg |
| Product Dimension | 167*81*69mm |
| Cooling Fan Start Condition | Output current > 8A or System temperature > 45℃ |
| Cooling Fan Shut Down Condition | Output current < 7.9A and System temperature < 45℃ |

Power Supply Unit (PSU) Specifications (RD-1200-68 example):
| Name | Switching Power Supply | Installation Guide | The Installation |
|---|---|---|---|
| Model | RD-1200-68 | Input Voltage | 100-120V/200-240V AC |
| Voltage | 68V | Working Temperature | -15℃~65℃ |
| Current | 17.7A@220V / 14.7A@110V | Output Power | 1200W@220V / 1000W@110V |
| Size | 242x125x65mm | Weight | About 1.45kg |

5. Product Overview
5.1 Front Panel

- A: Power button
- B: SHIFT Second function button
- C: Quick storage button
- D: Current/Over current protection setting
- E: Voltage/Over voltage protection setting
- F: Micro USB port
- G: Power supply output negative terminal / Battery charging negative terminal
- H: Battery charging positive terminal (Dedicated terminal for battery charging)
- I: Power supply output positive terminal (connect 4mm banana plug)
- J: Output ON/OFF switch
- K: Enter/Confirm button
- L: Encoder potentiometer (rotate) / Cancel button (Press)
- M: Direction button
- N: Keypad
- O: Screen
5.2 Back Panel

- P: Input fuse (Type: 1808)
- Q: Output fuse
- R: Power source input interface (HT508K/K14)
- S: External temperature sensor interface (XH2.54-2P)
- T: CR1220 battery socket
- U: Communication module interface (WiFi or RS485 board)
- V: Fan interface (cannot add or replace other fan)
- W: Remote sampling switch (only for RD6006P)
- X: Remote sampling terminal (only for RD6006P)
Fuse Specifications:
- RD6006/RD6006P: 10A fuse
- RD6012/RD6012P/RD6012H: 20A fuse
- RD6018: 25A fuse
- RD6024: 30A fuse (1808 fast blow fuse)
- RD6030: 40A fuse (1032 fast blow fuse)

6. Setup and Installation
6.1 General Assembly
The RD6024/RD6024W is designed for integration into a complete power supply system, typically requiring a matching case and an input Power Supply Unit (PSU). Ensure all connections are secure and correctly polarized.

6.2 Correct Installation Method
When installing the main unit into a case, ensure it is seated correctly to avoid damage or improper function.

6.3 PSU Recommendations
It is recommended to use a custom PSU or a reputable brand PSU for optimal performance. Ensure the PSU's output voltage is stable and matches the rated voltage before connecting to the RD power supply.
Recommended PSU types:
- Cost-effective, High Output Power, Good Performance
- Examples: 400W-65V, 1000W-68V
PSU types to avoid:
- Electric bike chargers, second-hand power supplies, modified power supplies, or PSUs claiming to be suitable for RD power supply but not officially recommended. These devices can have unstable and high output voltages, potentially damaging your load.

7. Operation Instructions
After power-on, the device will first show a boot image, then enter the main page.
7.1 Main Page Display
The main page displays input voltage, output voltage, output current, and output power. You can switch between different display styles (Traditional, Detailed, Curve) by pressing the left/right arrow buttons.

7.2 Output Voltage and Current Setting
To set the output current (AK), press the I-SET button. Use the encoder potentiometer to adjust the value directly or the keypad (N) to type in the value. Press ENTER to confirm. If a value exceeds the limit, an error will be prompted.
To set the output voltage (AL), press the V-SET button. The operation is similar to setting the output current.
To set Over-Current Protection (AI), press SHIFT + I-SET. For Over-Voltage Protection (AJ), press SHIFT + V-SET. Ensure your over-current protection value is higher than the current setting value if you want to use the auto cut-off function.
When the device is in constant voltage mode, it shows 'CU'. In constant current mode, it shows 'CC'. When working normally, a checkmark icon is displayed.
7.3 Data Group Quick Storage and Call Out
The device supports 10 data groups for storing and recalling settings.
- Store Data: Press
MEM+ keypad button (1-9) to store the current output voltage, current, over-voltage protection, over-current protection, and current range into the corresponding data group. - Call Out Data: Press
SHIFT+ keypad button (1-9) to quickly call out saved data.
7.4 Keypad Lock and Unlock
To lock or unlock the keypad, press SHIFT + LOCK. The keypad will automatically lock when communication starts and unlock after 3 seconds of disconnection.
7.5 System Settings
Press SHIFT + 0 to enter the system setting menu. Use the direction buttons (M) to navigate and the encoder potentiometer (L) to change settings. Settings are automatically saved upon exiting the menu.

- Language: Set to English by default. Options include Simplified Chinese, French, German, and Russian.
- Take OK: Default ON. Prompts for confirmation when recalling data groups. Set OFF to apply settings directly.
- Take Out: Default OFF. Keeps previous output status when recalling data groups. Set ON to output directly.
- Boot Power: Default OFF. Output is cut off on boot. Set ON to automatically turn on output.
- Boot Logo: Default ON. Shows boot logo. Set OFF to enter main interface directly.
- Buzzer: Default ON. Beeps when buttons are pressed. Set OFF to disable.
- Backlight: Set to level 4 by default. Adjustable from 0-5.
- Update Rate: Default Low. Sets the refresh rate of real output voltage and current. Options: Low/Mid/High.
- Max Power: Default 740W. Adjustable from 0-740W. If (setting voltage * setting current) exceeds max power, the device automatically decreases the output current.
- Temperature Unit: Default °C. Can be switched to °F.
7.6 System Information
To view system information, press SHIFT + 0, then press the right arrow button three times. This menu displays the product model, serial number, firmware version, and system temperature.
8. Battery Charging Function
The RD power supply can charge various types of batteries using its dedicated green charging terminals. Connect the green terminal (H) to the battery's positive electrode and the black terminal (G) to the negative electrode. Once connected, the AG battery charging indicator will turn red. Press ON/OFF to start charging, and the indicator will turn green.
Charging will automatically cut off if the actual output current falls below the user-set cut-off current value (default 10mA) or if the external temperature sensor detects a temperature exceeding the cut-off temperature value (default 60°C).
Warning: Non-professionals should not use the battery charging function. There is a risk of fire and explosion if charged incorrectly. Always upgrade to the latest firmware for a better battery charging experience.

For batteries with a protection board, use the red terminal (I: Power supply output positive terminal) and black terminal (G: Power supply output negative terminal) for charging. Set the charging voltage and current manually.
Common Battery Voltage Comparison Table:
| Battery Type | Nominal Voltage (V) | Final Charge Voltage (V) | Final Discharge Voltage (V) | Application | Characteristics |
|---|---|---|---|---|---|
| LiCoMnNiO2 | 3.7 | 4.2 | 3 | Digital Device | High capacity |
| LiFePO4 | 3.2 | 3.65 | 2.5 | Electric bike/tool | Large discharge current, inexpensive |
| Lead Storage Battery | 12 | 14.4 | 10.5 | Car/electric bike | Inexpensive, lead pollution |
| Dry Battery | 1.5 | Cannot charge | 0.9 | Clock/Remote control | Inexpensive, widely used, not rechargeable |
| NICD Battery | 1.25 | 1.5 | 1.1 | Toy | Inexpensive, memory effect |
| Ni-MH Battery | 1.2 | 1.4 | 0.9 | Toy/Shaver | No memory effect |
Common Electric Car/Bike Battery Voltage Comparison Chart:
| Nominal Voltage | Battery Type | Number of batteries connected in series | Final Discharge Voltage (V) | Final Charge Voltage (V) |
|---|---|---|---|---|
| 48V | LiCoMnNiO2 | 14 | 42 | 58.8 |
| LiCoMnNiO2 | 13 | 39 | 54.6 | |
| LiFePO4 | 16 | 40 | 58.4 | |
| Lead Storage Battery | 4 | 42 | 57.6 | |
| 36V | LiCoMnNiO2 | 10 | 30 | 42 |
| LiFePO4 | 12 | 30 | 43.8 | |
| 24V | Lead Storage Battery | 3 | 31.5 | 43.2 |
| LiCoMnNiO2 | 7 | 21 | 29.4 | |
| LiFePO4 | 8 | 20 | 29.2 |
Note: If the final discharge voltage of the battery is higher than 60V, you cannot use RD6024 to charge, it will damage the device.
9. PC Software Control
The PC software allows for comprehensive monitoring and control of the power supply. It features a user-friendly interface for setting parameters, viewing output graphs, and performing advanced functions.

9.1 Software Download and Installation
The PC software supports Windows 7-10. Download the software from the official link provided in the instruction card or PDF manual. Install the necessary drivers (e.g., CH341SER) before connecting the device via Micro USB.
Important: If your antivirus software flags the program, please allow it, as it is not a virus. Test the software before purchasing the product if you have concerns about compatibility.
9.2 Software Connection
Connect the RD6024 to your PC via a Micro USB cable. Choose the correct communication port, baud rate, and slave address (default 001) in the software, then click "CONNECT".
For RD6024-W models, WiFi connection is also supported. Set the device's communication interface to WiFi, restart, and then configure the WiFi network in the PC software. Note that WiFi functionality may have compatibility issues with some computers.
9.3 Basic Functions
The PC software allows for voltage/current preset, data group quick call out, calibration fine tuning, brightness setting, and voltage and current curve exporting. You can rotate the mouse wheel or enter values to set voltage and current. The graph displays real-time voltage and current curves, which can be zoomed in/out or exported.
9.4 Advanced Functions
The advanced function page allows you to set programmed output sequences. You can define up to 200 steps, each with a duration between 1 and 9999 seconds. The device can output automatically or manually based on the programmed sequence.
9.5 RS485 Multiple Devices Communication
Connect multiple RD6024 units via RS485. Each unit needs a different device address (up to 32 units). The PC software can search for and connect to multiple devices simultaneously. Output voltage and current can be changed individually or in batches.
10. Mobile App Control (RD6024-W only)
The RD6024-W model supports mobile app control via WiFi for both Android and iOS devices. This allows for remote monitoring and setting adjustments.

10.1 App Download and Installation
- Android: Download the APP zip-file from the official link or search "Ruideng tech" on Google Play (supports Android 8.0 and above).
- iOS: Search "Ruideng tech" on the Apple App Store (supports iOS 10.0-16.1, iPhone 6 and above). Older phones may still use the "RDPower" app.
Important: Do not install or remove the Wi-Fi module when the device is powered on, as this can cause damage. Ensure location services are enabled for WiFi functionality.
10.2 Wi-Fi Connection
For first-time connection, insert the WiFi board into the device. Power on the RD6024-W, and the blue LED should blink once. Set the communication interface to WiFi and restart the device. Place the RD6024-W and your mobile phone close to a 2.4G router (ensure your phone is on the same 2.4G network and the router's AP isolation function is disabled).
In the app, select "Add Device" (BB) and choose "RD power series". Enter your WiFi password and confirm you are using a 2.4G network. Press "INITIALIZATION" and wait for the connection to establish.
10.3 App Operation
Use the app to set output voltage (BJ) and current (BK) values. Adjust values using the wheel (BP) or by typing. The app allows for data export (voltage-current curves) to Excel files, recording up to 24 hours of data.
Note: Grant all necessary application permissions (background running, Bluetooth, folder access, etc.) to ensure proper app functionality and prevent system interruptions during data recording.
11. Firmware Update
Firmware updates can be performed via the PC software to add new functions and improve performance. It is recommended to keep your device updated to the latest firmware version.
11.1 Update Process
Connect the RD6024 to your computer. In the PC software, navigate to the firmware update section. If the device cannot start normally, press and hold the ENTER button while powering on to enter boot mode, then connect to the PC for update. The update process typically takes about 100 seconds.
Note: Firmware updates are not supported under WiFi connection mode.
11.2 Boot Logo Update
You can also update the boot logo via the PC software. Click "Start Logo Update" and select an image file. Sample logos may be available in the software installation package.
12. Calibration
The calibration fine-tuning function should only be performed by professional electronics personnel with a multimeter of six and a half digits or more. Incorrect operation can exceed hardware limits and cause damage, which is not covered by warranty.
12.1 Calibration Procedure
In the PC software, click "Calibration" and enter the password "168168". This will allow you to access the Calibration Fine Tuning page. The calibration adjusts the zero point and proportional value based on a linear function (y=kx+b) to match the device's readings with a precise multimeter.
- Voltage Calibration: Set the output voltage to 1V and adjust the zero point. Then set to 30V and adjust the proportional value.
- Current Calibration: Similarly, set the output current to 0.1A and adjust the zero point, then set to 3A and adjust the proportional value.
Warning: This section does not provide technical support. If you do not understand the process, please consult related information or seek professional help.
13. Troubleshooting
- Device Not Powering On: Check input voltage connections and ensure they are within the 7-70V DC range. Verify the fuse is intact.
- Output Not Working: Check for Over Voltage Protection (OVP), Over Current Protection (OCP), or Over Temperature Protection (OTP) indications on the screen. Ensure the output is enabled (ON/OFF switch).
- PC Software Connection Issues: Ensure the correct drivers are installed (CH341SER). Verify the correct COM port, baud rate, and slave address are selected. If using WiFi, ensure the device is in WiFi mode and your PC is on the same 2.4G network with AP isolation disabled.
- Mobile App Connection Issues: For RD6024-W, ensure the WiFi module is correctly installed and the device is in WiFi mode. Verify your phone is on a 2.4G network and AP isolation is disabled on your router. Grant all necessary app permissions. If using a Huawei phone, turn off the random MAC address function.
- Inaccurate Readings: Consider performing a calibration if you have the necessary equipment and expertise.
- Case Deformation/Scratches: Minor case deformation during shipping can often be adjusted by hand. Surface scratches do not affect product performance.
14. User Tips
- Firmware Updates: Regularly check for and install the latest firmware versions to access new features and improve device stability.
- Power Supply Selection: Always use a stable and reliable input power supply. Verify its output with a multimeter before connecting to prevent damage.
- Battery Charging Safety: Exercise extreme caution when charging batteries. Understand your battery's parameters and avoid using the charging function for long-term or critical applications if you are not a professional.
- Software Compatibility: If experiencing issues with PC software or mobile app, try different versions or ensure your operating system meets the requirements.
- Data Storage: Utilize the 10 data groups to quickly save and recall frequently used voltage and current settings for efficiency.
15. Warranty and Support
For any issues or technical support, please contact the seller or manufacturer. Damage caused by incorrect operation, such as exceeding input voltage limits or improper calibration by non-professionals, may not be covered under warranty.
We recommend referring to the official product page or contacting customer service for the most up-to-date warranty information and support resources.
PDF User Manual:
A detailed user manual in PDF format is available for download: View User Manual (PDF)