1. Introduction
The HICOMDATA JT-IPS303CM-62TS is a managed industrial switch designed for robust network applications. It features 4× 10/100/1000Base-T PoE ports and 2× Gigabit SFP optical ports, supporting up to 4×30W PoE loads simultaneously. This switch is built for harsh environments, offering a wide operating temperature range of -40°C to 75°C, excellent EMI/EMC performance, and 100% burn-in tested reliability. It is an ideal solution for industrial scenarios such as highways, rail transit, smart cities, and smart energy applications requiring high-bandwidth data integration.
This manual provides detailed instructions for the installation, operation, and maintenance of your HICOMDATA Industrial Gigabit L2 Managed PoE Switch.
2. Safety Information
- Ensure the power supply voltage is within the specified range (DC 44-57V) to prevent damage.
- Do not open the device casing; refer all servicing to qualified personnel.
- Protect the device from moisture and extreme temperatures outside the operating range.
- Ensure proper grounding to prevent electrical hazards.
- Disconnect power before cleaning or performing any maintenance.
3. Key Features
The JT-IPS303CM-62TS switch offers a comprehensive set of features for industrial networking:
- PoE Support: Ports 1-4 support IEEE 802.3af/at with a single-port maximum output power of 30W and a total PoE power budget of 120W.
- Gigabit Connectivity: 4× 10/100/1000Base-T ports and 2× Gigabit SFP optical ports for high-speed data transmission.
- Wide Voltage Input: Supports 44-57V DC redundant dual power input with over-voltage, over-current, and reverse polarity protection.
- Industrial Design: Operates in a wide temperature range (-40°C to 75°C), features IP40 protection, and a fanless DIN-rail design for harsh environments.
- Advanced Layer 2 Management: Includes VLAN (IEEE 802.1Q), Port Mirroring, IGMP, QoS, LLDP, 802.1X, DDM, IPv6 management, Web, SNMP, Telnet, TFTP, and Web upgrading.
- Redundancy: Supports STP/RSTP and ERPS (self-healing time ≤20ms) for network reliability.
- Protection: 4KV surge protection, 8KV contact ESD protection, and 15KV air ESD protection.
4. Package Contents
Verify that your package contains the following items:
| Product Information | Quantity | Unit |
|---|---|---|
| 2 Optical 4 Electrical Gigabit L2 Managed Industrial PoE Switch | 1 | tower |
| Quick Start Guide | 1 | share |
| Warranty card and certificate of conformity | 1 | share |
5. Installation
5.1 Mounting Options
The HICOMDATA Industrial Gigabit L2 Managed PoE Switch offers flexible mounting options:
- DIN-rail Mounting: Standard 35mm DIN-rail mounting for easy installation and minimal space usage.
- Wall-mount: Optional wall-mount bracket for secure installation on vertical surfaces.
5.2 Power Connection
The switch supports dual redundant power supplies for uninterrupted operation. Connect the power source to the removable 4-pin screw terminal (5.08mm) on the device. Ensure the input voltage is within the DC 44-57V range. The device includes reverse polarity protection.
5.3 Port Introduction
The switch is equipped with the following ports:
- 4*1000M POE RJ45 Ports: Auto-sensing, full/half duplex MDI/MDI-X auto-adaptive. Ports 1-4 support IEEE 802.3af/at PoE.
- 2*Gigabit SFP Ports: 1000BaseFX ports for optical fiber connections.
- Console Port: For command-line interface (CLI) management.
- Ground Wire Terminal: For proper grounding of the device.
6. Operating Instructions
6.1 Basic Network Connection
- Connect your network devices (e.g., IP cameras, IP phones, PCs) to the RJ45 PoE ports (1-4) using standard Ethernet cables.
- For fiber optic connections, insert compatible SFP modules into the Gigabit SFP ports (5-6) and connect fiber optic cables.
- Ensure the power supply is connected as described in Section 5.2. The power LED (P) should illuminate.
- Observe the LED indicators for port status:
- P (Power): Indicates power status.
- S (System Status): Indicates system operational status.
- 5-6 (Optical Port): Indicates link/activity for SFP ports.
- 1-4 (Electrical Port): Yellow for PoE activity, Green for Link/Act.
6.2 Web-based Management
The switch supports Web-based network management, allowing you to configure and monitor the device through a web interface.
- Connect a PC to any of the switch's RJ45 ports.
- Configure your PC's IP address to be in the same subnet as the switch's default IP address (refer to the Quick Start Guide for default IP).
- Open a web browser and enter the switch's IP address.
- Log in using the default username and password (refer to the Quick Start Guide).
- Once logged in, you can access various management functions such as VLAN configuration, QoS settings, port mirroring, and system monitoring.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid or aerosol cleaners.
- Environment: Ensure the operating environment remains within the specified temperature and humidity ranges.
- Firmware Updates: Regularly check for and apply firmware updates via the web management interface to ensure optimal performance and security.
- Inspection: Periodically inspect power connections and cable integrity.
- Fanless Design: The fanless design reduces maintenance needs related to moving parts, but ensure adequate airflow around the device.
8. Troubleshooting
- No Power: Check the power supply connections and ensure the input voltage is correct. Verify the power LED (P) is illuminated.
- No Link/Activity: Check Ethernet or fiber optic cable connections. Ensure connected devices are powered on and functioning correctly. Verify the corresponding port LEDs (1-4 or 5-6) are active.
- PoE Device Not Powering On: Ensure the connected device is PoE compatible (IEEE 802.3af/at). Check the PoE budget and individual port power output.
- Cannot Access Web Interface: Verify your PC's IP address is in the same subnet as the switch. Check network cable connections. Try resetting the switch to factory defaults if the default IP/credentials are unknown (refer to the Quick Start Guide for reset procedure).
- Network Performance Issues: Check for excessive network traffic or loops. Utilize QoS settings to prioritize critical traffic.
9. Specifications
9.1 Hardware Features
| Attribute | Description |
|---|---|
| Product Number | JT-IPS303CM-62TS |
| Product Name | 2 Optical 4 Electrical Gigabit L2 Managed Industrial PoE Switch |
| Port Configuration | 2×1.25G SFP optical ports + 4×10/100/1000M auto-sensing PoE RJ45 ports |
| Network Protocols | IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-X, IEEE 802.3x, IEEE 802.1D, IEEE 802.1W, IEEE 802.1Q, ITU-T G.8032, IEEE 802.1X, IEEE 802.1ab, IEEE 802.3ad, IEEE 802.3af/at |
| RJ45 Ports | 10/100/1000M auto-detection, full/half duplex MDI/MDI-X auto-adaptive |
| Optical Ports | 1000BaseFX ports (SFP slots) |
| Switch Attributes | Layer 2; Switching Capacity: 12Gbps; Packet Forwarding Rate: 17.856Mpps; MAC Table: 16K; Packet Buffer: 2M; Jumbo Frame: 10KBytes; Forwarding Latency: <5µs; Forwarding Mode: Store-and-Forward |
| LED Indicators | P: Power; S: System Status; 5-6: Optical Port; 1-4: Electrical Port (Yellow: PoE; Green: Link/Act) |
| Power Supply | Input Voltage: 44-57VDC; Terminal: Removable 4-pin screw terminal (5.08mm), dual power redundancy; reverse polarity protection |
| Power Consumption | ≤4W (full load without PoE); PoE Budget ≤120W |
| Operating Environment | Operating Temperature: -40°C-75°C; Storage Temperature: -40°C-85°C; Operating Humidity: 10%-90% RH (non-condensing); Storage Humidity: 5%-95% RH (non-condensing) |
| Industry Standards | Power Surge: IEC 61000-4-5 4KV/2KV (8/20µs); Port Surge: IEC 61000-4-5 4KV/2KV (10/700µs); ESD: IEC 61000-4-2 8KV/15KV; Shock: IEC 60068-2-27; Free Fall: IEC 60068-2-32; Vibration: IEC 60068-2-6 |
| Mechanical Properties | Housing: IP40, metal; Installation: DIN-rail, wall-mount (optional); Cooling: Fanless natural convection; Dimensions: 130×98×30mm (L×W×H); Weight: 0.6kg |
| Certifications | CCC, CE, RoHS, FCC |
| MTBF | 300,000 hours |
9.2 Software Specifications
| Attribute | Description |
|---|---|
| Link Aggregation | Supports GE port aggregation; static aggregation; dynamic aggregation |
| Port Features | Supports IEEE 802.3x flow control; port traffic statistics; port isolation; storm control based on port rate percentage |
| PoE | Complies with 802.3af (15.4W) and 802.3at (30W); supports 1,2+/3,6- power supply; PoE power management |
| MAC Address Table | Static MAC address management; dynamic MAC address management; filtered MAC address |
| VLAN | Supports access, trunk, and hybrid modes |
| Port Mirroring | Many-to-one port mirroring |
| Layer 2 Ring Protocols | Supports IEEE 802.1w RSTP, STP; supports G.8032 ERPS (single ring, interconnected sub-rings) |
| Multicast | IGMP snooping |
| QoS | Ingress port-based rate limit; egress port-based rate limit |
| Security Features | Supports 802.1X, port authentication, MAC authentication, RADIUS |
| Management & Maintenance | Supports LLDP; user management, login authentication, privilege control; SNMP v2c/v3; Web management (HTTP 1.1, HTTPS); Syslog (classified alarms); RMON; DDM; NTP; Telnet Server/Client; SSH Server; TFTP, Web firmware upgrade; TFTP Client |
10. User Tips
- For optimal performance in high-bandwidth applications, consider utilizing the SFP ports with appropriate fiber optic modules.
- When deploying in critical industrial settings, always leverage the dual redundant power supply feature for maximum uptime.
- Regularly monitor the switch's status via the web management interface to proactively identify and address any potential issues.
11. Warranty and Support
This product comes with a 5-year warranty. For detailed warranty terms and conditions, please refer to the included Warranty Card and Certificate of Conformity.