1. Product Introduction
The Heltec HT-CC20ABP/HT-CC40ABP battery capacity tester is a high-precision device designed for comprehensive battery performance evaluation. It integrates advanced capacity series discharge detection with high-precision charging functions. This tester is capable of analyzing various battery types, including cadmium-nickel batteries, lithium battery packs, and lead-acid batteries, within a voltage range of 9-99V.
It is an ideal tool for electric vehicle dealers and battery manufacturers to accurately assess battery performance. Its functionalities include testing battery capacity, executing charge and discharge cycles, and configuring complex test steps via a connected computer. The device ensures precise real-time collection of battery voltage signals, data storage, and efficient processing, offering high precision, strong timeliness, simple operation, and practical reliability.
2. Product Features
- High-Precision Measurement: Integrates high-precision capacity discharge detection and precision series charging to ensure accurate and reliable test data.
- Automatic Data Collection and Analysis: Automatically collects and analyzes battery voltage, providing continuous constant current or power output.
- Software Control: Connects to a host computer for convenient and efficient software-based control.
- Adjustable Current: The charging and discharging current is adjustable, with peak discharge current reaching up to 40A (for HT-CC40ABP).
- Reverse Polarity Protection: Ensures battery safety by protecting against reverse polarity connections of positive and negative terminals.
- Simplified Operation Interface: Real-time display of voltage, capacity, current, and other parameters, supporting both Chinese and English languages.
- Powerful PC Software: Offers comprehensive functions including data management, exporting, analysis, and report statistics.
- Intelligent Cooling Fan: Features an intelligent cooling fan for faster heat dissipation and improved performance.
- Temperature Sensor: Real-time monitoring of battery temperature.

Key features: High-Precision Measurement, Wide Battery Compatibility, Professional Use Cases.

Features: 1 Channel, Upper Computer, Intelligent Cooling Fan, Temperature Sensor, Multiple Functions.
3. Specifications
General Specifications
| Attribute | Value |
|---|---|
| Brand Name | Heltecbms |
| Model Number | HT-CC20ABP/HT-CC40ABP |
| Type | Electronic Device Battery Tester |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE |
| Power Source | AC |
| Battery Included | No |
| High-concerned chemical | None |
Performance Specifications
| Parameter | HT-CC20ABP | HT-CC40ABP |
|---|---|---|
| Scope of Application | Lead-acid/lithium/nickel-cadmium or other batteries within 9-99V | |
| Charging Range | 9-99V, 0.1V adjustable; 0.5-10A, 0.1A adjustable | 9-99V, 0.1V adjustable; 0.5-20A, 0.1A adjustable |
| Discharge Range | 9-99V, 0.1V adjustable; 9V-21V: 0.5-10A, 0.1A adjustable; 21-99V: 0.5-20A, 0.1A adjustable | 9-99V, 0.1V adjustable; 0.5-40A, 0.1A adjustable |
| Operation Step | Charge/discharge/rest/cycle (up to 99 times) | |
| Upper Computer Communication | Systems above WIN XP, supports both Chinese and English | |
| Protection Function | Battery reverse polarity protection | |
| Measuring Error | Voltage ±0.03V, current ±0.03A (accuracy guarantee period is within one year from the date of purchase) | |
| Attention | It is prohibited to test batteries with voltage exceeding 99V | |
| Equipment Power Supply | AC220V 50HZ | |
| Dimensions & Weight | Length 60cm, width 57cm, height 27cm, net weight 15Kg | |
| Preset Charging Capacity at End of Cycle | 0-99AH (Setting 0 indicates no preset) | |

Product Parameters table for HT-CC20ABP model.

Product Parameters table for HT-CC40ABP model.

Product dimensions and included accessories.
4. Setup and Connections
4.1 Product Appearance and Components

Front panel of the Heltec Battery Tester (HT-CC20ABP model shown).
Front Panel Components:
- Start/Stop Button: Press to start, press again while running to pause. To resume, press again. (Any operation must be paused first in running state).
- Set Button: Used to adjust parameters.
- Display Screen: Shows various parameters such as current, voltage, capacity, and time.
- Battery Terminals: Positive and negative terminals for battery connection. Ensure correct polarity; do not connect reversely.
Rear Panel Components:
- Main Switch Button: Power on/off switch.
- Power Input Interface: Connect the power cord here.
- Status Indicator Light: Provides operational status feedback.
- Data Transmission Interface: For connecting to a computer.

HT-CC20ABP front view with labeled components.

HT-CC40ABP front view with labeled components.

HT-CC20ABP rear view with labeled components.

HT-CC40ABP rear view with labeled components.
4.2 Package Contents
Ensure all items are present in the package:
- Battery Tester Unit (HT-CC20ABP or HT-CC40ABP)
- Temperature Collection Line x1
- Clamping Line x1
- Power Cord x1
- Data Collection Line x1

Product package contents: Temperature collection line, clamping line, power cord, data collection line.

Package contents list.
4.3 Initial Setup
- Connect the power cord to the Power Input Interface (6) and plug it into an AC220V 50HZ power outlet.
- Connect the clamping lines to the battery terminals, ensuring correct polarity (red to positive, black to negative). The positive and negative terminals of the battery must not be connected reversely.
- For temperature measurement, connect the temperature collection line to the TEMP port. There are two collection methods: laying flat on the battery pack or inserting into fixture holes (for both positive and negative poles).
- Connect the data collection line from the device's Data Transmission Interface (8) to your computer for software control and data analysis.
- Turn on the Main Switch Button (5).

Temperature Measurement methods: laid flat on battery pack or inserted into fixture holes.

Reverse Connection Protection diagram showing incorrect polarity and warning.
5. Operating Instructions
5.1 Device Operation
If the device is turned on, rotate the SET button (2) to adjust the mode and set parameters. The display screen (3) shows real-time voltage, current, charging/discharging operation time, charging/discharging capacity, and current operating status.

Automatic Collection: Display of real-time voltage, current, time, capacity, and mode selection on the device screen.
Working Modes:
| Mode | Description |
|---|---|
| 00 | Historical data query |
| 01 | Capacity testing (discharge) |
| 02 | Charging mode |
| 03 | Start with discharge and end with charge, with a cycle count of 1-50 times |
| 04 | Start with charging and end with charging, with a cycle count of 1-50 times |
| 05 | Start with discharge and end with discharge, with a cycle count of 1-50 times |
| 06 | Start with charging and end with discharging, with a cycle count of 1-50 times |
| 07 | Networking mode (automatically changes to this mode when the device is started by the computer) |
Indicator Light Description:
- Data Indicator Light:
- Green light flashing - channel data exchange
- Green light constantly off - no channel data
- Network Indicator Light:
- Green light flashing - No network cable connected
- Green light flashing - network cable connected, software not connected
- Green light is constantly on - software is connected
5.2 Parameter Setting
After selecting a mode, set the corresponding parameters. Use the SET knob to adjust values. For example, in discharge mode, adjust the minimum discharge cut-off voltage and discharge current. In charging mode, adjust charging cut-off voltage, charging current, and charging cut-off current. In cycle mode, both charging and discharging parameters need to be adjusted.
Mode 00 - Inquire:
Rotate the black setting knob. The mode bar in the lower right flashes. Rotate the knob to set mode "00". The LCD will display data from the last single charge or discharge. Continue rotating to view data for subsequent loops.
Mode 01 - Discharge:
After power on, press the black setting knob. The mode selection bar flashes. Rotate the knob to set mode "01". Continue pressing the knob to set the minimum discharge cut-off voltage, then the discharge current. Once set, press the red START button to begin discharge. Judge battery condition based on discharge time.
Mode 02 - Charging:
Similar to discharge mode, set mode "02". Then set the maximum charging voltage, charging current, and charging cut-off current using the black setting knob. Press the red START button to begin charging.
Mode 03 - Loop:
Set mode "03". Configure the loop number (1-99 times), maximum charging voltage, charging current, charging cut-off current, minimum discharge voltage, discharge current, last loop charging capacity (0-99.9AH), and loop step interval (0-20 mins). Press the red START button to begin the charge-discharge loop.
5.3 Upper Computer Software for Battery Testing
Software Installation and Connection:
- Find and open the installation software.
- Choose an installation location (avoid C drive if possible).
- After installation, open the software. During the first run, select the network (check public network if firewall is enabled).
- Click "Connect", then "Search". Select your device from the list, click "Connect Device", and then "OK" in the IP Settings window.
Demonstration of the Heltec Battery Tester in operation, showing connections and software interface.
Main Software Interface:
After connecting, battery information (current voltage, operating current, test capacity, test time, work step number, working status, test status, temperature, and equipment model) will be displayed. Double-clicking a device shows detailed settings.
Work Step Setting:
Click the "Step Settings" button. Create a new step, name it, and then click to edit. Add steps to set charging/discharging parameters, cycles, etc. Save the work steps. You can select multiple batteries for testing by holding Ctrl or Shift.
Data Storage Conditions:
To save test data, check the relevant item in the software. You can set the minimum time interval, voltage interval, and current interval for data saving. Avoid setting these values too small to prevent slow computer operation.
Data Export and Analysis:
The software allows exporting data in XLS report format. Use the "Analysis" function to retrieve record files and launch the data curve analyzer. The analyzer supports 3Y axes, single timeline, panning, and zooming for detailed data review.
6. Maintenance
- Keep the device in a cool and well-ventilated place.
- Do not block the air inlet and outlet to ensure proper cooling.
- Avoid violent actions such as collisions during use and transportation.
- Regularly check all connecting cables to ensure they are firmly connected.
- If the device stops running unexpectedly, press the red "Start" button for 5 seconds to resume operation.
- Ensure the device is properly grounded. High voltage is present inside; do not open if you are not a professional.

Product Size/List for HT-CC20ABP, showing dimensions and included accessories.
7. Troubleshooting
| Encountered Problem | Reason | Solution |
|---|---|---|
| Display screen does not light up after power on |
|
|
| Display screen lights up, but does not display any content |
|
|
| Set knob is invalid |
|
|
| Equipment producing abnormal noise |
|
|
| No voltage display after connecting the battery |
|
|
| Charging fails after the start button is pressed |
|
|
8. User Tips
- Testing Accuracy: The effectiveness of capacity testing is related to both time and speed. Faster testing can lead to a decrease in capacity (Pickett effect). For improved accuracy, it is recommended to set a smaller discharge current value.
- Damaged Batteries: This tester cannot accurately test damaged batteries. Battery damage includes increased internal resistance, terminal voltage lower than discharge cut-off, or internal short/open circuits.
- Heat Dissipation: After each charge or discharge cycle, allow the battery a period of time to dissipate heat before proceeding with further tests.
- Software Installation: When installing the software, avoid installing it on the C drive if possible, and ensure the public network firewall is configured correctly to avoid connection issues.
- Multiple Measurements: If a single measurement seems inaccurate, perform multiple measurements to ensure reliability.
9. Warranty and Support
9.1 Warranty Regulations
The warranty service period for this product is 1 year from the date of purchase.
Warranty Limitations: The warranty is limited to normal use and does not cover:
- Man-made damage.
- Self-disassembly, modification, or unauthorized repair.
- Usage not in accordance with the provided instructions.
- Damage caused by external force majeure factors.
Accessories such as test fixtures are considered consumables and are not covered by warranty.
9.2 Support and Service
For warranty service or any technical inquiries, please contact your dealer for processing. If you are unable to reach your dealer, you may contact Chengdu Heltec Energy Technology Co., Ltd. directly via email or phone.
Please note that there are no after-sales service stations in countries outside of China. If you require warranty service and are located outside China, you will need to send the product to us for free repair. However, the customer is responsible for the freight costs for the round trip.
You may download the host computer software via the QR code provided in the manual or contact customer service for the software link.
10. Safety Instructions
- Always connect the battery with the correct polarity. Incorrect connections can damage the device and the battery.
- Ensure all connections are secure and stable before operating the device.
- Keep the device away from flammable and explosive materials.
- Operate the device in a cool and well-ventilated area.
- Do not block the air inlet and outlet of the device.
- Store the device properly and avoid any violent actions, such as dropping or strong impacts, during use and transportation.
- Read this instruction manual carefully before use. If you have any questions or difficulties, contact customer service.