Schneider LC1D

Contents

Schneider LC1D Series AC Contactor User Manual

Brand: Schneider Electric | Model Series: LC1D

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of Schneider LC1D Series AC Contactors. These contactors are designed for controlling various electrical loads in industrial and commercial applications. Please read this manual thoroughly before using the product.

2. Safety Information

WARNING: HAZARDOUS VOLTAGE!

Turn off all power supplying this equipment before working on it. Failure to follow this instruction will result in death or serious injury. Installation and maintenance should only be performed by qualified personnel.

  • Always disconnect power before installation, maintenance, or troubleshooting.
  • Ensure proper grounding of the equipment.
  • Use appropriate personal protective equipment (PPE).
  • Verify all connections are secure and correctly wired according to diagrams and local electrical codes.

3. Product Overview

The Schneider LC1D Series AC Contactors are robust and reliable components for motor control and power switching. Key features include:

  • Imported Flame-Retardant Shell: Constructed from high flame-retardant material, ensuring durability, wear resistance, high temperature resistance, and corrosion resistance for enhanced safety.
  • High-Purity Purple Copper Coil: Features fine and multi-stranded copper wire, capable of withstanding high voltage, ensuring high purity, quality, and extended service life.
  • Silver Alloy Contact: Utilizes Schneider core technology for silver alloy contacts, allowing for larger current carrying capacity, stronger conductivity, and sensitive contact operation.
Detailed view of contactor components highlighting flame-retardant shell, copper coil, and silver alloy contacts.
Figure 1: Internal Components and Material Quality

Product Appearance Update

Schneider Electric TeSys series products have transitioned to new color schemes as of December 8, 2021. While the appearance may vary between older and newer stock, the product performance, quality, and dimensions remain unchanged. Newer products include an anti-counterfeit QR code and UKCA mark certification.

Comparison of old and new product appearance and packaging for Schneider contactors.
Figure 2: Old vs. New Product Appearance and Packaging

4. Specifications

General Specifications

Attribute Value
Model NumberLC1D
Main Circuit Rating CurrentUp to 100A
Main Circuit Rating VoltageUp to 690V
Phase3
Number of Pole3
Electricity TypeAC
OriginMainland China
CertificationCE
Wireless FunctionalityNo
Battery IncludedNo
High-concerned chemicalNone

Coil Voltage Options

Available coil voltages include 24V, 36V, 48V, 110V, 220V, and 380V AC. Specific codes are used to denote these voltages:

  • B7: AC24V
  • CC7: AC36V
  • E7: AC48V
  • F7: AC110V
  • M7: AC220V
  • Q7: AC380V

Approximate Dimensions (LC1D09 example)

Dimensions may vary slightly by model, but for LC1D09, the approximate measurements are:

  • Height: 77mm
  • Width: 45mm
  • Depth: 84mm
Dimensions of LC1D09 contactor showing height, width, and depth.
Figure 3: LC1D09 Dimensions

Performance Characteristics

Characteristic Value
Rated Control Voltage (Ue)690V
Control Voltage Limit (50/60Hz)0.8...1.1 Ue
Heat Dissipation (50/60Hz Coil)2.5W
Heat Dissipation (Sprial-bound)7.5W
Mechanical LifeUp to 1 million operations
Electrical Life (DC-13)3600 operations per hour
Minimum Switching Capacity17mA
Short Circuit ProtectionGG Fuse: 10A
Rated Making Capacity140A
Rated Breaking Capacity120A
Insulation Resistance>10MΩ

Rated Working Current (AC-3, 690V)

Model Current (A)
LC1D099
LC1D1212
LC1D1818
LC1D2525
LC1D3232
LC1D3838

Connection Data (Screw-Clamped)

Wire Type Size (mm²) Screwdriver Tightening Torque (N.m)
Soft wire (without terminals)1-4N°21.7
Soft wire (with terminals)1-4N°21.7
Hard wire1-6N°21.7

5. Installation

Mounting

LC1D series contactors can be mounted on standard DIN rails. For models LC1D09 to LC1D70, use AM1DP200, DR200, or AM1ED200 (35mm width) rails. For larger models like LC1D80-D95 and LP1D40-D80, use AM1DL200/DL201 (75mm width) or AM1ED/AM1ED200 (35mm width) rails.

Coil Voltage Confirmation

Before connecting, confirm the coil voltage. The AC coil voltage is typically indicated on the top of the product. For DC control coil voltage, the parameter value is directly marked below the model number on the front of the product.

Diagram showing coil voltage identification on a contactor, using LC1D09M7C as an example.
Figure 4: Coil Voltage Identification

Wiring Diagram

Follow the wiring diagram carefully to ensure correct and safe operation. Connect the Live (L) and Neutral (N) wire terminals from your power supply. Incorporate a fuse or circuit breaker for protection, and connect control elements such as stop and start buttons before wiring to the contactor and finally to your load.

Wiring diagram for a contactor circuit including power supply, fuse, stop/start buttons, and load.
Figure 5: Contactor Wiring Diagram

6. Operation

The LC1D series AC contactor operates by receiving a control signal (voltage) to its coil, which then energizes an electromagnet. This electromagnet pulls the main contacts together, allowing power to flow to the connected load (e.g., a motor). When the control signal is removed, the electromagnet de-energizes, and springs separate the contacts, interrupting power to the load.

Ensure that the control circuit voltage matches the contactor's coil voltage for proper operation. Auxiliary contacts can be used for interlocking or signaling purposes within the control circuit.

7. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your AC contactor:

  • Visual Inspection: Periodically check for any signs of physical damage, discoloration due to overheating, or excessive dust accumulation.
  • Cleanliness: Keep the contactor free from dust, dirt, and moisture. Use a dry, soft brush or compressed air for cleaning.
  • Connection Checks: Ensure all terminal connections are tight and free from corrosion. Loose connections can lead to overheating and arcing.
  • Contact Wear: While silver alloy contacts are durable, inspect them for excessive wear or pitting over time. Replace the contactor if contacts are severely degraded.
  • Operational Check: Occasionally test the contactor's operation by activating and deactivating the control circuit to ensure smooth and consistent switching.

8. Troubleshooting

If you encounter issues with your LC1D series AC contactor, consider the following common problems and solutions:

Problem Possible Cause Solution
Contactor does not energize (coil not pulling in)
  • No control voltage to coil
  • Incorrect coil voltage
  • Open circuit in control wiring
  • Damaged coil
  • Check control circuit power supply
  • Verify coil voltage matches supply voltage
  • Inspect control wiring for breaks or loose connections
  • Replace contactor if coil is faulty
Contactor hums loudly or chatters
  • Low control voltage
  • Mechanical obstruction
  • Damaged shading coil (AC contactors)
  • Loose mounting
  • Ensure adequate control voltage
  • Check for foreign objects
  • Replace contactor
  • Tighten mounting screws
Contactor contacts weld or stick
  • Overcurrent/short circuit
  • Excessive arcing
  • Frequent switching under heavy load
  • Check load for faults, ensure proper overload protection
  • Verify contactor rating is suitable for the application
  • Replace contactor

If problems persist, consult a qualified electrician or Schneider Electric support.

9. User Tips

  • Verify Coil Voltage: Always double-check the coil voltage rating on your contactor against your control circuit's supply voltage before installation. Mismatched voltages can lead to malfunction or damage.
  • Proper Wire Sizing: Use wires of appropriate gauge for the main circuit current to prevent overheating and ensure efficient power transfer. Refer to local electrical codes for guidance.
  • Secure Connections: Ensure all screw terminals are tightened to the specified torque. Loose connections are a common cause of intermittent operation, arcing, and heat buildup.
  • Consider Overload Protection: When using the contactor for motor starting, pair it with a suitable Schneider overload relay (e.g., LR series) to protect the motor from overcurrents.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official Schneider Electric website or contact your local authorized distributor. Keep your purchase receipt as proof of purchase.

11. Additional Resources

Product Video

Watch this video for a visual overview of the Schneider LC1D series contactor, showcasing its features and design.

Video 1: Schneider LC1D Contactor Showcase

User Manual (PDF)

A detailed user manual in PDF format is available for further reference. This document contains comprehensive technical drawings, additional specifications, and detailed installation instructions. You can find this document on the official Schneider Electric support page or by searching for the product model on their website.

© 2024 Schneider Electric. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.