1. Introduction and Overview
Thank you for choosing the Lionshee 800W Balcony Solar Kit. This system is a core conversion device for solar photovoltaic power generation, efficiently converting DC power from photovoltaic modules into AC power that meets grid standards. It supports both self-consumption and feeding surplus power back to the grid, making it ideal for household rooftop PV, balcony PV, and RV applications.
This kit features a true plug-and-play design for easy setup without professional tools or complex wiring. The ultra-thin 2.5mm flexible solar panels are lightweight (3.98kg each), portable, and adaptable to various surfaces.

2. Safety Instructions
Please read and strictly adhere to all safety warnings to prevent electric shock, fire, equipment damage, or personal injury.
- This equipment operates with high voltage. All installation, wiring, inspection, and disassembly must be performed by qualified professional electricians. Non-professionals are strictly prohibited from operating it.
- The DC input voltage is extremely high. Strictly prohibit reverse polarity, short circuits, or plugging/unplugging live DC connectors. Doing so will instantly burn out the inverter and may cause fire or electric shock.
- Before thunderstorms, immediately disconnect the DC input switch and AC grid-tie switch, unplug the power cord, and implement lightning protection measures to prevent damage to the equipment and grid.
- During operation, the casing and heat dissipation areas will generate heat. Do not touch heat sinks, wiring terminals, or other high-temperature areas to prevent burns.
- Do not disassemble, modify, or tamper with the inverter. Breaking the equipment's seals will void the product warranty and may lead to safety hazards.
- Keep children and elderly away from the equipment and its installation area. Prevent contact with the equipment, wiring, and interfaces to avoid accidental injury.
- Do not stack flammable, explosive, damp, or corrosive materials around the equipment. Do not directly rinse the equipment with water to prevent short circuits or fire.
- When the grid power fails, the inverter will automatically shut down. Do not force start it to prevent back-feeding power to the grid, which could cause electric shock.
3. Package Contents
Please check the package contents upon arrival to ensure all components are present and undamaged:
- 200W Flexible Solar Panel x 4
- 800W Microinverter x 1
- 5M AC Cable x 1
- Stainless Steel Ties x 24

4. Specifications
| Parameter | Value | Notes |
|---|---|---|
| Model Number | Lionshee 800W Balcony Solar Kits | - |
| Product Name | Balcony Solar System (On Grid) | - |
| Application | Balcony, Home, Garden, Roof Top, RVs | - |
| Solar Panel Type | Monocrystalline Silicon (200W Flexible Solar Panel) | - |
| Microinverter | 800W Smart Solar Hub | - |
| Controller Type | MPPT (Integrated) | - |
| Mounting Type | Balcony Mounting | - |
| DC Input Voltage Range | DC 120V~500V | Adapts to mainstream household PV panels |
| Rated AC Output Voltage | AC 220V-240V (Single-phase) | Complies with national grid standards |
| Rated Output Frequency | 50Hz ± 0.5Hz | Synchronized with grid |
| Load Power (W) | 800W | - |
| Conversion Efficiency | ≥ 97.5% (Peak 96%) | High efficiency, low loss |
| Protection Class | IP67 (Panels & Inverter) | Dustproof, waterproof, indoor/outdoor |
| Operating Temperature Range | -30°C~+60°C | Adapts to different climates |
| Communication Method | WiFi wireless, RS485 | Supports mobile APP remote monitoring |
| Protection Functions | Island protection, over/under voltage, over current, over temperature, short circuit, leakage | Multiple protections, safe and reliable |
5. Setup and Installation
This kit is designed for easy, plug-and-play installation. However, for safety and optimal performance, please follow these guidelines carefully.
5.1 Installation Environment Requirements
- Install in a dry, well-ventilated, shaded area, away from dampness, oil smoke, open flames, and flammable/explosive materials. Avoid direct sunlight on the inverter to prevent overheating.
- The inverter must be mounted vertically on a flat, firm wall capable of supporting its weight. Ensure at least 30cm of heat dissipation space above, below, and to the sides of the inverter. Do not install in sealed boxes.
- Install away from strong electromagnetic interference sources (e.g., transformers, high-power motors) to avoid affecting normal operation.
- For outdoor installations, implement rain and sun protection measures. Ensure all equipment interfaces are waterproof and sealed to prevent water ingress.
5.2 Wiring Requirements
Before wiring, ensure all switches are in the OFF position. Strictly distinguish DC positive and negative poles. Do not reverse connections or short circuits. Ensure all connections are firm and secure to prevent poor contact, which can lead to heat generation or malfunction.
- DC Wiring: Connect the positive (+) output of the solar panels to the DC+ input of the microinverter. Connect the negative (-) output of the solar panels to the DC- input of the microinverter. Use high-temperature resistant, appropriately sized DC cables that meet load requirements.
- AC Wiring: Connect the AC output of the microinverter to the grid connection terminals. Ensure the Live (L), Neutral (N), and Ground (PE) wires are connected correctly. Do not reverse connections. Use national standard copper core cables and install an appropriate AC circuit breaker.
- Grounding: The microinverter must be reliably grounded. The grounding resistance should be ≤4Ω. Use a copper core cable of at least 2.5mm² for grounding. Ensure the grounding terminal connection is firm to prevent leakage.
- Ancillary Equipment: Install a DC circuit breaker on the DC side and an AC circuit breaker on the AC side. Their specifications should match the rated power of the microinverter for easy fault diagnosis and equipment protection.


5.3 Post-Installation Inspection
After installation, a professional electrician must perform a comprehensive inspection. The microinverter can only be powered on after confirming the following:
- All wiring is correct, with no reverse polarity or short circuits. All interfaces and terminals are securely connected.
- Grounding is reliable, and the grounding resistance meets requirements.
- DC and AC circuit breakers are installed correctly and operate normally.
- The equipment surface is undamaged, heat dissipation vents are not blocked, and the installation is firm.
6. Operating Instructions
6.1 Startup Procedure
- Confirm all wiring is correct, and both the DC circuit breaker and AC grid-tie switch are in the OFF position.
- Close the DC circuit breaker on the solar panel side to provide DC input power to the microinverter.
- Wait for approximately 30 seconds. The microinverter will perform an automatic self-check, the panel power light will illuminate, and it will enter standby mode.
- Close the AC grid-tie switch. The microinverter will automatically detect the grid voltage and frequency. Once it confirms compliance with grid requirements, it will automatically start generating power.
- Observe the panel indicator lights: The Run light should be solid green, and the Grid light should be solid yellow. This indicates normal power generation.
6.2 Shutdown Procedure
- First, open the AC grid-tie switch to stop the microinverter from feeding power to the grid.
- Next, open the DC circuit breaker to cut off the DC input from the solar panels to the microinverter.
- If you will be away for an extended period or if the equipment requires maintenance, you can unplug the microinverter's power cord to ensure it is completely de-energized.
6.3 Panel Operation Description
The microinverter's control panel includes indicator lights, a display screen, and a function button, allowing for simple and intuitive monitoring of the equipment's operating status:
- Power Light (Green): Solid = Equipment is powered on normally; Off = Equipment is not powered or disconnected.
- Run Light (Green): Solid = Equipment is operating normally and connected to the grid; Flashing = Equipment is performing self-check, in standby, or experiencing a minor anomaly; Off = Equipment is shut down.
- Fault Light (Red): Solid = Equipment has a fault and has automatically shut down for protection; Flashing = Fault warning, requires immediate inspection.
- Grid Light (Yellow): Solid = Grid is normal and allows grid connection; Flashing = Grid voltage or frequency is abnormal, preventing grid connection; Off = Not connected to the grid.
- Display Screen: Shows key parameters such as real-time power generation, daily power generation, cumulative power generation, DC input voltage, and AC output voltage.
- Function Button: Short press = Switches between displayed parameters; Long press (3 seconds) = Restarts the equipment (use only in case of malfunction).
6.4 APP Remote Monitoring Operation
- Scan the QR code located on the microinverter's body to download the corresponding brand's mobile APP. Complete registration and login.
- On your mobile phone, enable Wi-Fi and connect to the microinverter's built-in Wi-Fi hotspot (the name is indicated on the microinverter).
- Within the APP, search for the device and complete the binding process. You can then remotely monitor the system.
- The APP provides various functions, including real-time viewing of power generation data, equipment operating status, fault records, operation logs, remote setting of operating modes (e.g., self-consumption/full feed-in), and receiving fault alarm notifications.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar kit.
7.1 Routine Maintenance (Monthly)
- Clean Equipment: Use a dry, soft cloth to wipe dust and stains from the microinverter's surface and heat dissipation vents. Do not rinse directly with water to prevent moisture from entering the equipment.
- Check Wiring: Inspect all wiring terminals and interfaces for any signs of looseness, overheating, or oxidation. Tighten any loose connections and replace any aged or damaged cables promptly.
- Check Status: Observe the panel indicator lights and display screen to confirm that the equipment is operating normally and no fault alerts are displayed. Ensure the heat dissipation vents are clear and unobstructed.
- Waterproof Check: For outdoor installations, inspect the waterproof seals on all interfaces to ensure they are intact and there are no signs of water ingress.
7.2 Regular Maintenance (Annually)
- Professional Inspection: Contact after-sales service personnel to conduct a comprehensive inspection of the microinverter's conversion efficiency, insulation performance, grounding resistance, and core components. This ensures the equipment's performance remains normal.
- Clean Cooling System: Clean any accumulated dust and debris from the heat sinks to ensure effective heat dissipation and extend the equipment's service life.
- Check Ancillary Equipment: Inspect the operating status of the DC circuit breaker and AC grid-tie switch to ensure they can be opened and closed normally without damage.
7.3 Long-Term Storage Maintenance
- Disconnect all power switches (DC circuit breaker and AC grid-tie switch) and unplug the power cord to ensure the equipment is completely de-energized.
- Cover the equipment with a dust cloth to prevent dust accumulation and protect the surface and interfaces.
- Power on the equipment once every 3 months and let it run for 30 minutes. This helps check the equipment's status and prevents component aging.
- Store the equipment in a dry, ventilated, and shaded environment to avoid dampness and exposure to direct sunlight.
8. Troubleshooting
This section provides solutions for common issues you might encounter. If the problem persists, please contact customer support.
| Fault Phenomenon | Possible Cause | Troubleshooting Method |
|---|---|---|
| No power generation, no display |
|
|
| Fault light solid, equipment stopped |
|
|
| Grid-tie failed, grid light flashing |
|
|
| Low power generation |
|
|
| Equipment abnormal noise or overheating |
|
|
| APP cannot bind or view data |
|
|
9. User Tips
No specific user tips are available from provided reviews or Q&A content.
10. Warranty and Support
10.1 Warranty Terms
- Warranty Period: The main unit (inverter) has a 5-year warranty, and core components (power module, control board) have a 10-year warranty. The warranty period is calculated from the product purchase date, based on the purchase invoice or product qualification certificate.
- Warranty Scope: During the warranty period, equipment malfunctions or damage caused by product quality issues are eligible for free repair or component replacement services, with no repair fees charged.
- Out of Warranty Scope: The following situations are not covered by the warranty, and repair costs will be borne by the user:
- Malfunctions or damage caused by unauthorized installation, wiring, disassembly, modification, or tampering with the equipment by non-professionals.
- Damage caused by human operational errors, collisions, drops, external impacts, or natural disasters (e.g., lightning strikes, floods, typhoons).
- Equipment malfunctions (e.g., poor heat dissipation, wiring errors) caused by failure to use or maintain the equipment according to the instructions in this manual.
- Damage to product seals or unauthorized replacement of components.
- Normal wear and tear of consumable parts (e.g., wiring terminals, seals).
- Malfunctions or damage to ancillary equipment such as solar panels, electricity meters, or cables (these are not covered by the inverter's warranty).
10.2 After-Sales Process
If your equipment experiences a malfunction, please follow these steps:
- Call the after-sales hotline.
- Provide the product model, a detailed description of the malfunction, and proof of purchase.
- After-sales personnel will provide timely guidance for troubleshooting. If the issue cannot be resolved remotely, on-site inspection and repair services will be arranged.
10.3 Contact Information
- After-Sales Hotline: 400-XXXX-XXXX (Monday to Sunday, 9:00-18:00)
- After-Sales Email: XXXXXX@163.com
- Company Address: XXXXXXX